Page 1
Electro thrown in the trash or abandoned in nature, pose a threat to the environment and human health. Purpose ZI-17 is used to supply electrical and electronic equipment that requires a stable, filtered supply voltage independent of the ma- ins voltage changes.
Page 3
Technical data input voltage 100÷264 V AC output voltage 14.5 V DC output current 0.8 A output power 12 W current limitation 110% Iout load minimum keying frequency 70 kHz terminal 2.5 mm² screw terminals tightening torque 0.4 Nm working temperature -10÷40°C dimensions 1 module (18 mm)
Page 4
Warranty F&F products are covered by a 24-month warranty from the date of purchase. The warranty is only valid with proof of purchase. Contact your dealer or contact us directly. CE declaration F&F Filipowski sp. j. declares that the device is in conformity with the essential requirements of The Low Voltage Directive (LVD) 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/UE.