The RC68+ programmer is a 55 key hand-held device that generates all the IR
codes necessary for the set up and operation of Xantech IR remote controlled
products. Such products include models ZPR68, RAT1, MIRV1, GATEKEEP-IR,
etc. The RC68+ is an upgrade of the previous 32 key RC68. While providing
additional key-code command capabilities, it retains all previous RC68 program-
ming in a similar 32 key layout section on the keypad.
GENERAL
• The RC68+ is used initially for the setup of system control parameters and IR
Code Groups for Xantech products.
• It is then used to "teach" a basic set of operational IR commands into universal
learning devices such as the Xantech URC series learning remotes, the
Xantech Smart Pads, the 590 Programmable Controller, the 710 Fone Link,
etc., for the end user.
• Included with the RC68+ is a set of keypad overlays. These overlays are marked
with command names that apply to specific Xantech models. They are provided
to make it easier for the installer when setting up the system. See Fig. 2 and
the model listings below.
• While the RC68+ will operate as a separate remote control, it is highly
recommended it not be given to the final user for the following reasons:
• Since it includes special setup codes, the user may inadvertently alter the
installer configurations.
• Also, since the user will require IR commands from other brands of equipment to control the total system,
in addition to those of the RC68+, all commands should be consolidated into one learning device, for ease
of use.
THE RC68+ OVERLAY SYSTEM
• The RC68+ base unit comes with a permanently attached keypad overlay (A) with lettering that identifies
the commands for operation of the model ZPR68 and other models with similar commands.
• Additional temporary overlays are included for use with
Xantech models that differ greatly from the ZPR68.
• The overlays are simply placed over the RC68+ keys, as
needed. Use the overlay that corresponds to the Xantech
model or models you are working with, as listed below.
Xantech Model
RAT1, MIRV1, ............................................ A
RGC11, RP41AV,
RS41AV, ZPR68,
ZPR68-10
AC2, CC12, SR21 ...................................... B
RT8, RT16-10 ............................................ C
680-10, 686-10, CC62 ............................... D
Gatekeep-IR Modules ................................ E
IR-DC4 (RC68+ IR-to-RS232, Arrakis) ...... F
SmartPad
.................................................. I
3
RC68+

INSTALLATION INSTRUCTIONS

RC68+
RC68+ Overlay Id Letter
(permanently attached
to the RC68+)
A
0
OFF
ON
A
B
C
ADJ-OFF
1
OFF
ON
1
2
3
4
1
2
OFF
ON
INPUT
5
6
7
8
5
3
OFF
ON
GLOBAL
9
4
OFF
ON
TREBLE
BASS
Z-ADJ
VOL
13
5
OFF
ON
MUTE
GP-ON GP-OFF
6
OFF
ON
ON
OFF
7
OFF
ON
E-FLAT
LAST
MAX-V
TRIM
OFF
C-BAL
Permanently
attached
"A" Overlay.
RC68+ PROGRAMMER
FIG. 2 Overlays for the RC68+ Programmer
A
A
B
C
ADJ-OFF
80
48
10
90
01
1
2
3
4
00
C0
50
D0
41
INPUT
5
6
7
8
40
A0
30
B0
21
GLOBAL
20
E0
70
F0
61
TREBLE
BASS
VOL
Z-ADJ
60
88
18
98
09
MUTE
08
A8
38
B8
29
ON
OFF
28
E8
78
F8
69
E-FLAT
LAST
MAX-V
TRIM
68
C8
58
D8
49
OFF
C-BAL
E1
89
C9
A9
E9
71
19
59
39
79
F1
99
D9
B9
F9
RC68+ PROGRAMMER
Overlay
B
Identification
TGL
MMT
Letter
C
TGL
MMT
2
3
4
D
TGL
MMT
1
6
7
8
OFF
ON
TGL
MMT
TGL
MMT
E
2
10
11
12
1
OFF
ON
TGL
MMT
TGL
MMT
ON
OFF
OPEN
CLOSE
3
14
15
16
F
2
OFF
ON
TGL
MMT
TGL
MMT
ON
OFF
OPEN
CLOSE
1
4
1
2
3
PLAY
OFF
3
ON
TGL
MMT
TGL
MMT
I
ON
2
OFF
OPEN
CLOSE
5
0
1
4
5
6
STOP
4
OFF
ON
TGL
MMT
TGL
MMT
ON/TOG
OFF
ON/TOG
OFF
ON
3
OFF
OPEN
CLOSE
6
2
3
7
8
9
PAUSE
5
OFF
ON
TGL
MMT
ON/TOG
OFF
ON/TOG
OFF
ON
4
OFF
OPEN
CLOSE
4
5
CD#
0
TR#
RESUME
6
GP-ON
ON/TOG
OFF
ON/TOG
OFF
ON
5
OFF
OPEN
CLOSE
6
7
DISC --
DISC +
TR --
TR +
7
GP-OFF
ON/TOG
OFF
ON/TOG
OFF
ON
6
OFF
OPEN
CLOSE
8
9
1 CD
ALL CD
SEQL RANDOM
8
ON/TOG
OFF
ON/TOG
OFF
ON
7
OFF
OPEN
CLOSE
A
B
ARTIST
TITLE NUMBER ZONE
ON/TOG
OFF
ON/TOG
OFF
8
C
D
LEFT
RIGHT
ENTER SELECT
ON/TOG
OFF
ON/TOG
OFF
E
F
ON/TOG
OFF
ON/TOG
OFF
1

Advertisement

loading

Summary of Contents for Xantech RC68 Plus

  • Page 1: Installation Instructions

    PROGRAMMER / REMOTE CONTROL The RC68+ programmer is a 55 key hand-held device that generates all the IR codes necessary for the set up and operation of Xantech IR remote controlled products. Such products include models ZPR68, RAT1, MIRV1, GATEKEEP-IR, etc.
  • Page 2: Command Definitions

    • For detailed information that defines the button commands relating to each overlay, refer to the Installation Instructions that come with each specific Xantech model. • The only exception to this is for the model ZPR68; complete command definitions for it are included on the pages that follow.
  • Page 3 The RC68+ may also be used to change the Code Group Number within the Xantech model itself, so that it is different than the factory setting. This is necessary when two or more of the same Xantech model are used in the same IR system. See CODE GROUP SETTING PROCEDURES.
  • Page 4 CHANGING THE INTERNAL CODE GROUP NUMBER OF A XANTECH MODEL 1. Connect a Xantech IR receiver (Model 780, 480, etc.) to the IR terminals of the Xantech device you wish to change (RAT1/MIRV1, RT16-10, etc.) along with the correct power supply.
  • Page 5 (i.e., 48, D0, C0, etc.). These numbers are printed on the front face of each RC68+ button! (See item #17, Fig. 3). 4. Aim the RC68+ at the Xantech IR receiver (780, 480, etc.) and press the button that has the number on it that you decided on.

This manual is also suitable for:

Rc68+