Replace the battery compartment cover.

9 Low battery indicator

If the battery level in the device reaches a critical level, the
battery level symbol appears in the appropriate place on the
display.
NOTICE! The symbol for the battery level indicator is only
displayed when the batteries are empty. If the battery level
is sufficient, the icon will not be displayed.

10 Automatic measurement display

As soon as the power supply has been established, the tem-
perature and humidity measurements are automatically dis-
played on the device.
NOTICE! If no measurement values are shown within 3
minutes, remove the batteries and reinsert them.

11 Mould alert

1.
In normal display mode, press the [DOWN] button for
about 3 seconds to enter the mold alarm setting mode.
The mould alarm and humidity symbols blink.
2.
Press the [UP] or [DOWN] button to set the desired
value. Possible values: 60%, 65%, 70%, and 75%.
3.
Press [DOWN] button again for about 3 seconds to save
the setting. The mold alarm is triggered when the hu-
midity reaches the set value.
4.
If the set value for the mould alarm is exceeded, the
mould alarm symbol flashes until the humidity has
fallen below the set value again.
12 Humidity alarm
1.
In normal display mode, press the [MODE] button for
about 3 seconds to enter the humidity alarm setting
mode. The upper humidity limit icon flashes.