Download Print this page

Watermark aquaBUBBLER Classic Pre-Installation page 2

Advertisement

I M P O R T A N T > > >
Consult
2
1
Schematic
Mark measurements and
dimensions as indicated
by Schematic:
publ i c . a quabubbl e r . c o m. a u/ d oc s / A B12_Sc h emat i c . p df
Classic
AB12
publ i c . a quabubbl e r . c o m. a u/ d oc s / A BUA13_Sc h emat i c . p df
Universal
ABUA13
publ i c . a quabubbl e r . c o m. a u/ d oc s / A B2UA14_Sc h emat i c . p df
Universal 2 AB2UA14
Schematic is also available for
download from our website
Universal
6a
aquaBUBBLER
only
1
3
1
3
2
2
Installation must be in accordance with AS/NZS 3500.1 and AS/NZS 3500.2
Installation
Classic/Universal aquaBUBBLER
Unit must be installed by a Certified Plumber
Locate Internal Base Mounting Plates
Place Base Mounting Plate (BMP) halves
in position on the installation surface.
Position the BMP so that the Front of the
unit will be in the middle of 2 holes.
Mark anchor points on the surface
through BMP holes and drill out.
Fit o either 12 mm threaded rods
or 16mm dynabolts*
Remove
Self-Sealing
Trap inside to
gain access to the base of the unit.
Place unit over anchors, then place
BMP halves back inside unit over
anchors and secure in place.
*Indicates correct gauges for anchor
system types listed; choice of anchor
(between two holes)
system is at installer's discretion
Units with
Attach Side Pod
6b
Dog Bowl (DB)
only
Connect pipe to
1
tap fitting
Connect Black
2
Director from
Pod to the
Waste Pipe
3
Screw Side Pod
to body with a
5mm Allen Key
(not supplied)
ATTENTION PLUMBER: See previous page for PRE-INSTALLATION GUIDE
Flush out
3
the lines
before connecting to
unit in order to
eliminate particulate
matter (copper &
brass filings)
BMP
Front of unit
will end up here
7
DON'T FORGET:
Attach DB
Insert coach bolts
through square
holes (either side
of DB)
Secure bolts from
inside of unit
with washer and
lock nut
Maximum Water Pressure: 1500 kPa / Maximum Temperature: 40°C
- failure to do so will void all warranties.
Install
4
Isolation Valve
(not supplied)
on mains line,
external to unit
(recommended)
water
mains
water
supply
Seal all plumbing
Apply sealant to
T-junction pipe ends
before insertion into
other pipes
Check for leaks
Run taps and adjust
any insecure
connections
Don't install Self-
5
Sealing Trap below
the pod
8
SET UP FOR USE:
Run the tap
until the pod is full
Adjust water pressure
Rotate keyhole with a
5mm screwdriver to
adjust water pressure
Advise client to check
water pressure 48 hours
a er installation, as it may
require re-adjustment
Leave T15 Post Torx
Security Screwdriver
with client