Panasonic U-8ME2R8 Installation Instructions Manual page 65

Table of Contents

Advertisement

2. Dimensions of Wind Ducting
Reference diagram for air-discharge chamber (field supply)
Can be installed so that the air direction is to the front or rear direction.
According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from "A", "B" or "C".
E
D1
11
d1
Unit 1
Combination
Capacity
1
2
8HP
8
10HP
10
12HP
12
14HP
14
16HP
16
18HP
18
20HP
20
22HP
10
12
24HP
12
12
26HP
10
16
28HP
12
16
30HP
14
16
32HP
16
16
34HP
14
20
36HP
16
20
38HP
18
20
40HP
20
20
42HP
10
16
44HP
12
16
46HP
14
16
48HP
16
16
50HP
14
16
52HP
16
16
54HP
14
20
56HP
16
20
58HP
18
20
60HP
20
20
62HP
14
16
64HP
16
16
66HP
10
16
68HP
12
16
70HP
10
20
72HP
16
16
74HP
16
18
76HP
16
20
78HP
18
20
80HP
20
20
The air-discharge chamber will be obtained at a local field. According to the installation site, you may choose the setting position in the
depth direction of the anchor bolt from A, B or C.
A: 964 (Installation hole pitch) : For removing tube forward. Use the data with the asterisk (*1) in combination of each unit dimension.
B: 730 (Installation hole pitch) : For removing tube downward. Use the data with the asterisk (*2) in combination of each unit dimension.
C: 730 (Installation hole pitch) : Use the data with the asterisk (*2) in combination of each unit dimension.
F
E
D2
d2
Unit 2
Unit 3
D1
D2
3
4
770
770
1180
1180
1180
1540
1540
770
1180
1180
1180
770
1180
1180
1180
1180
1180
1180
1180
1180
1540
1180
1540
1540
1540
1540
1540
16
770
1180
16
1180
1180
16
1180
1180
16
1180
1180
20
1180
1180
20
1180
1180
20
1180
1540
20
1180
1540
20
1540
1540
20
1540
1540
16
16
1180
1180
16
16
1180
1180
20
20
770
1180
20
20
1180
1180
20
20
770
1540
20
20
1180
1180
20
20
1180
1540
20
20
1180
1540
20
20
1540
1540
20
20
1540
1540
E
D3
D4
d3
d4
Unit 4
Separate dimensions of air-discharge chamber
D3
D4
d1
748
748
1158
1158
1158
1518
1518
748
1158
748
1158
1158
1158
1158
1158
1518
1518
1180
748
1180
1158
1180
1158
1180
1158
1540
1158
1540
1158
1540
1158
1540
1158
1540
1518
1540
1518
1180
1180
1158
1180
1180
1158
1540
1540
748
1540
1540
1158
1540
1540
748
1540
1540
1158
1540
1540
1158
1540
1540
1158
1540
1540
1518
1540
1540
1518
65
11
Distance between
d2
d3
d4
E( * 1)
1158
60
1158
60
1158
60
1158
60
1158
60
1158
60
1518
60
1518
60
1518
60
1518
60
1158
1158
60
1158
1158
60
1158
1158
60
1158
1158
60
1158
1518
60
1158
1518
60
1518
1518
60
1518
1518
60
1518
1518
60
1518
1518
60
1158
1158
1158
60
1158
1158
1158
60
1158
1518
1518
60
1158
1518
1518
60
1518
1518
1518
60
1158
1518
1518
60
1518
1518
1518
60
1518
1518
1518
60
1518
1518
1518
60
1518
1518
1518
60
Unit: mm
1003
Dimensions of air-
units
discharge chamber
E( * 2)
F( * 1)
F( * 2)
770
770
770
770
1180
1180
1180
1180
1180
1180
1540
1540
1540
1540
180
2010
2130
180
2420
2540
180
2010
2130
180
2420
2540
180
2420
2540
180
2420
2540
180
2780
2900
180
2780
2900
180
3140
3260
180
3140
3260
180
3250
3490
180
3660
3900
180
3660
3900
180
3660
3900
180
4020
4260
180
4020
4260
180
4380
4620
180
4380
4620
180
4740
4980
180
4740
4980
180
4900
5260
180
4900
5260
180
5210
5570
180
5620
5980
180
5570
5930
180
5620
5980
180
5980
6340
180
5980
6340
180
6340
6700
180
6340
6700