Grainger 55GU72B Operating Instructions And Parts Manual

Digital oil control gun with flex extension

Advertisement

Available languages

Available languages

Quick Links

Operating Instructions and Parts Manual
Please read and save these instructions. Read through this owner's manual carefully before using product. Protect your-
self and others by observing all safety information, warnings, and cautions. Failure to comply with instructions could
result in personal injury and/or damage to product or property. Please retain instructions for future reference.
Description
The digital inline electronic oil control gun is designed to dispense
motor oils (SAE 5-50), gear oils (SAE 80-140) and automatic
transmission fluid.
Specifications
Products Series
Flow Rate Range
Operating Pressure (Max.)
Working Temperature
Accuracy
5-digital Lcd Display
Inlet And Outlet Connections
General Safety Information
WARNING:
Read the safety warnings and instructions
in this manual carefully, before installation and use of the
oil control gun. It is the responsibility of the purchaser to retain
this manual for future reference. Failure to comply with the
recommendations stated in this manual may damage the oil
control gun and void factory warranty. Wear ear and eye
protection. Before doing any maintenance on the oil control gun,
be certain all pressure is completely vented from the pump,
suction, discharge, piping, and all other openings and connec-
tions. Be certain the air supply is closed or shut down, so that it
cannot be started while work is being done on the oil control
gun. Be certain that approved eye protection and protective
clothing are worn at all times in the vicinity of the oil control gun.
Failure to follow these recommendations may result in serious
injury or death.
DANGER:
NEVER use with fluids that have a flash
point below 100ºF (38ºC). Examples: gasoline, alcohol.
Sparking could result that will cause serious personal injury,
death, or major property damage.
IMC100 55GU72B
Printed in China
Digital Oil Control Gun
with Flex Extension
55GU72B
1-35L/min(1.06-36.99QT/min)
750 psi
15°F~140°F / -10°C~60°C
±0.5%
Quarts, Pints, Gallons, Liters
Inlet: 1/2 in NPT; Outlet: 1/4 in NPT
CAUTION:
circumstances should the oil control gun be aimed at
any person. Personal injury may be caused.
Meter Features
- 5-digit liquid crystal display shows volume for each delivery
and total.
- 4 units of measure: L, GAL, PT and QT.
- Accurate to the second decimal place.
- Low battery indicator.
- 2 buttons: "Move", "Reset".
Volume each time
Low battery indicator
Move
05/2023
Version 0
55GU72B
Maximum fluid pressure 750 PSI. Under no
Four Units
Total Volume
Reset

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 55GU72B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Grainger 55GU72B

  • Page 1 DANGER: NEVER use with fluids that have a flash Move Reset point below 100ºF (38ºC). Examples: gasoline, alcohol. Sparking could result that will cause serious personal injury, death, or major property damage. IMC100 55GU72B 05/2023 Printed in China Version 0...
  • Page 2 Operating Instructions and Parts Manual 55GU72B Digital Oil Control Gun with Flex Extension Operating Instructions LCD Display Key (Figure 1): 1. Before placing meter in operation. ① Partial register (5 figures with moving comma from 0.1 to The digital oil control gun is equipped with a 1/2” (NPT) female 99999) indicating the volume dispensed since the reset thread on the inlet side.
  • Page 3 Operating Instructions and Parts Manual 55GU72B Digital Oil Control Gun with Flex Extension Measurement unit change (Figure 4) Procedure for Entering the Correction Factor Directly Press MOVE and RESET together and hold for more than 3 Carefully follow the procedure indicated below.
  • Page 4 Operating Instructions and Parts Manual 55GU72B Digital Oil Control Gun with Flex Extension Modify the Correction Factor in the Field. Carefully follow the procedure indicated below. 1. Wait for the meter to go standby. (Figure 11) (Figure 11) 2. Reset the resettable total. (Figure 12) (Figure 12) 3.
  • Page 5: Troubleshooting Guide

    Operating Instructions and Parts Manual 55GU72B Digital Oil Control Gun with Flex Extension TROUBLESHOOTING GUIDE Symptom (s) Possible Causes(s) Corrective Action(s) Slow or no fluid flow. 1. Filter is clogged, or pump pressure is low, 1. Relief the pressure. or shut-off valve is not fully open, or foreign 2.
  • Page 6 Operating Instructions and Parts Manual 55GU72B Digital Oil Control Gun with Flex Extension For Repair Parts, call 1-800-Grainger 24 hours a day – 365 days a year Please provide the following: - Model Number - Serial Number (if any) - Part description and number as shown on parts list...
  • Page 7 Operating Instructions and Parts Manual 55GU72B Digital Oil Control Gun with Flex Extension For Repair Parts, call 1-800-Grainger 24 hours a day – 365 days a year Please provide the following: - Model Number - Serial Number (if any) - Part description and number as...
  • Page 8: Warranty

    Incidental or consequential damages are excluded from this warranty. For purchasers and/or delivery outside the United States, please use the following applicable contact information: W. W. Grainger, Inc. Lake Forest, IL 60045, USA or call 1-800-Grainger...
  • Page 9: Especificaciones

    NUNCA use con fluidos que tengan un punto de inflamación por debajo de 100ºF (38ºC). Ejemplos: gasolina, alcohol. Podría haber chispas que causen lesiones personales graves, muerte o daños materiales impor- tantes. IMC100 55GU72B 05/2023 Impreso en China Versión 0...
  • Page 10: Instrucciones De Operación

    Instrucciones de Operación y Manual de Piezas 55GU72B Pistola de Control de Aceite Digital con Extensión Flexible Instrucciones de Operación Pantalla LCD Botones (Figura 1): 1. Antes de poner en marcha el medidor. ① Indicador parcial (5 cifras con coma móvil de 0,1 a 99999) La pistola de control de aceite digital está...
  • Page 11 Instrucciones de Operación y Manual de Piezas 55GU72B Pistola de Control de Aceite Digital con Extensión Flexible Cambio de unidad de medida (Figura 4): Procedimiento para ingresar directamente el factor de Presione MOVE y RESET juntos y manténgalos presionados corrección.
  • Page 12 Instrucciones de Operación y Manual de Piezas 55GU72B Pistola de Control de Aceite Digital con Extensión Flexible Modificar el factor de corrección en el campo: Siga cuidadosamente el procedimiento indicado a continuación. 1. Espere a que el medidor se ponga en espera.
  • Page 13: Guía De Solución De Problemas

    Instrucciones de Operación y Manual de Piezas 55GU72B Pistola de Control de Aceite Digital con Extensión Flexible GUÍA DE SOLUCIÓN DE PROBLEMAS Síntoma(s) Posibles causa(s) Acción(es) correctiva(s) Flujo de fluido lento o 1. El filtro está obstruido, la presión de la 1.
  • Page 14 Instrucciones de Operación y Manual de Piezas 55GU72B Pistola de Control de Aceite Digital con Extensión Flexible Para piezas de repuesto, llame al 1-800-Grainger 24 horas al día, 365 días al año Proporcionenos la siguiente información: - Número de modelo - Número de serie (si corresponde)
  • Page 15 Instrucciones de Operación y Manual de Piezas 55GU72B Pistola de Control de Aceite Digital con Extensión Flexible Para piezas de repuesto, llame al 1-800-Grainger 24 horas al día, 365 días al año Proporcionenos la siguiente información: - Número de modelo - Número de serie (si corresponde)
  • Page 16: Garantía Limitada De 2 Años

    Para obtener información sobre garantías para compradores y/o entregas fuera de los Estados Unidos, utilice la siguiente información de contacto aplicable: W. W. Grainger, Inc. Lake Forest, IL 60045, EE. UU. o llame al 1-800-Grainger...
  • Page 17: Spécifications

    Ne JAMAIS utiliser avec des fluides dont le point d'éclair est inférieur à 38°C (100°F). Exemples: essence, alcool. Des étincelles pourraient se produire et provoquer des blessures graves, la mort ou des dommages matériels importants. IMC100 55GU72B 05/2023 Imprimé en Chine Version 0...
  • Page 18: Utilisation Quotidienne

    Mode d’emploi et manuel de pièces 55GU72B Pistolet de contrôle d'huile numérique avec extension flexible Mode d’emploi Écran ACL Touche (Figure 1): 1. Avant de mettre le compteur en fonction. ① Registre partiel (5 chiffres séparés par une virgule entre 0.1 Le pistolet numérique de contrôle de l'huile est équipé...
  • Page 19 Mode d’emploi et manuel de pièces 55GU72B Pistolet de contrôle d'huile numérique avec extension flexible Changement d’unité de mesure (Figure 4) Procédure pour entrer le facteur correctif directement. Appuyer sur MOVE et RESET ensemble et tenir enfoncer pour Suivre avec attention la procédure indiquée ci-dessous.
  • Page 20 Mode d’emploi et manuel de pièces 55GU72B Pistolet de contrôle d'huile numérique avec extension flexible Modifier le facteur de correction dans le champ. Suivre avec attention la procédure indiquée ci-dessous. 1. Attendez que le compteur soit en mode veille. (Figure 11) (Figure 11) 2.
  • Page 21: Guide De Dépannage

    Mode d’emploi et manuel de pièces 55GU72B Pistolet de contrôle d'huile numérique avec extension flexible GUIDE DE DÉPANNAGE Problème (s) Cause (s) possible (s) Action (s) corrective (s) Lent ou aucun débit 1. Le filtre est bouché ou la pression de 1.
  • Page 22 Mode d’emploi et manuel de pièces 55GU72B Pistolet de contrôle d'huile numérique avec extension flexible Pour les pièces de rechange, composez le 1-800-Grainger 24 heures par jour, 365 jours par année Veuillez fournir les renseignements suivants: - Numéro de modèle - Numéro de série (le cas échéant)
  • Page 23 Mode d’emploi et manuel de pièces 55GU72B Pistolet de contrôle d'huile numérique avec extension flexible Pour les pièces de rechange, composez le 1-800-Grainger 24 heures par jour, 365 jours par année Veuillez fournir les renseignements suivants: - Numéro de modèle - Numéro de série (le cas échéant)
  • Page 24: Garantie Limitée De 2 Ans

    Les dommages indirects et accessoires sont exclus de cette garantie. Pour les acheteurs et/ou la livraison à l'extérieur des États-Unis, veuillez utiliser les coordonnées suivantes: W. W. Grainger inc. Lake Forest, IL 60045, USA ou composez le 1-800-Grainger Size: 210x285mm 157克双铜...

Table of Contents