WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Toshiba shall not be liable for any damages, losses, expenses or costs, if any, incurred in connection with or as a result of use of any information or data provided...
Hazardous Substances. From July 1, 2006, the RoHS Directive will prohibit any marketing of new products containing the restricted substances. Increasing attention is given to issues related to the global environmental. Toshiba Corporation recognizes environmental protection as a key management tasks, and is doing its utmost to enhance and improve the quality and scope of its environmental activities.
(1 / 3) SAFETY INSTRUCTION WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "SAFETY PRECAUTION" AND "PRODUCT SAFETY NOTICE" INSTRUCTIONS BELOW. Safety Precaution WARNING: SERVICING SHOULD NOT BE ATTEMPTED BY ANYONE UNFAMILIAR WITH THE NECESSARY PRECAUTIONS ON THIS RECEIVER. THE FOLLOWING ARE THE NECESSARY PRECAUTIONS TO BE OBSERVED BEFORE SERVICING THIS CHASSIS.
Page 7
(2 / 3) 8. Always ensure that all internal wirings are in accordance before re-assembling the external casing after a repairing completed. Do not allow internal wiring to be pinched by cabinets, panels, etc. Any error in reassembly or wiring can result in electrical leakage, flame, etc., and may be hazardous.
Page 8
(3 / 3) sinusoidal waveforms. The measuring instrument is calibrated by comparing the frequency factor of with the solid line in figure F.2 of IEC 60990 at various frequencies. A calibration curve is constructed showing the deviation of from the ideal curve as a function of frequency.
FIRMWARE UPDATING PROCEDURE Analog - Digital SW update via USB 1. Please copy the files to USB device (root). Mb9x_en.bin mboot.bin usb_auto_update.txt 2. Turn power to OFF by mechanical switch or removing AC plug and plug the USB to TV 3.
HOTEL MODE/HOTEL CLONE HOTEL TV MENU: To enter hotel menu, please open main menu by pressing MENU(M) button. When you code following password "7935", hidden hotel TV menu appears as below: Figure: Hotel TV Menu Hotel Mode Setting "Hotel Mode" item 'On' activates hotel mode. In other words user can do only what he/she is allowed to do.
Page 11
Enables (Fixed Volume Enable = On) or prohibits (Fixed Volume Enable = Off) the use of fixed volume value which is set by menu item "Fixed Volume Value". If Fixed Volume Enable is ON, volume cannot be set to a value other than the Fixed Volume Value. Fixed Volume Value Sets the fixed value the volume can have.
Page 12
Main menu: Installation, Channel list Settings menu: Language, parental, Sources, Other settings Startup Position Specifies the starting channel when TV is switched ON. May take one of following values: AUTO (Last channel when TV is turned off) TV (TV channel number 1) Other enabled external sources via service menu or config tool (EXT1, HDMI2, PC, FAV, SVHS etc.) Teletext...
TROUBLESHOOTING (17MB95M) A. NO BACKLIGHT PROBLEM Problem: If TV is working, led is normal and there is no picture and backlight on the panel. Possible couses: Backlight pin, dimming pin, backlight supply, stby on/off pin BACKLIGHT_ON/OFF pin should be high when the backlight is ON. R119 must be low when the backlight is OFF.
Page 33
Backlight power supply should be in panel specs. Please check Q33, shown below; also it can be checked TP53. STBY_ON/OFF_NOT should be low for tv on condition, please check Q11’s collector.
Page 34
B. CI MODULE PROBLEM Problem: CI is not working when CI module inserted. Possible couses: Supply, suply control pin, detect pins, mechanical positions of pins. CI supply should be 5V when CI module inserted. If it is not 5V please check CI_PWR_CTRL, this pin should be low.
Page 36
C. STAYING IN STAND-BY MODE Problem: Staying in stand-by mode, no other operation This problem indicates a short on Vcc voltages. Protect pin should be logic high while normal operation. When there is a short circuit protect pin will be logic low. If you detect logic low on protect pin, unplug the TV set and control voltage points with a multimeter to find the shorted voltage to ground.
Page 37
E. KEYPAD TOUCHPAD PROBLEMS Problem: Keypad or Touchpad is not working Check keypad supply on MB95M.
Page 38
F. USB PROBLEMS Problem: USB is not working or no USB Detection. Check USB Supply, It should be nearly 5V. Also USB Enable should be logic high. G. NO SOUND PROBLEM Problem: No audio at main TV speaker outputs. Check supply voltages of 24V VDD_AUDIO, 3.3V AUDIO_AVDD and AUDIO_DVDD with a voltage- meter.
Page 39
H. STANDBY ON/OFF PROBLEM Problem: Device can not boot, TV hangs in standby mode. There may be a problem about power supply. Check main supplies with a voltage-meter. Also there may be a problem about SW. Try to update TV with latest SW. Additionally it is good to check SW printouts via Teraterm.
Page 40