12 MAINTENANCE AN CLEANING

We recommend regular servicing by a SMEG authorised service centre at least once a year, to
guarantee optimal performance at all times.
Consumables (e.g. peristaltic pump hoses) and/or parts subject to wear and tear must be replaced
with genuine SMEG parts. N.B.: the manufacturer accepts no liability for wilful damage or damage
deriving from carelessness, neglect, failure to comply with instructions, regulations and standards
or incorrect connections, which lead to forfeiture of warranty cover.
The dishwasher has IPX4 protection, but the use of direct water jets for cleaning is
forbidden.
Remove the filters (simply lift them out as shown here), taking
care that no large residues fall into the sump underneath. Clean
them to remove residues and rinse with plenty of water, then put
them correctly back in place; do not use sharp or pointed tools.
Clean away any limescale deposits to prevent excessive build-ups;
If possible, leave the hood or door ajar when not in use;
Clean surfaces thoroughly and often with a damp cloth; use
neutral, non-abrasive detergents which do not use chlorine
compounds, which corrode and damage stainless steel.
Do not use the products mentioned above even when cleaning the floor underneath or in the vicinity
of the dishwasher, to ensure that fumes or drops cannot damage the steel surfaces.

12.1 Cleaning the filter during the day

In case of particularly heavy-duty working conditions, the filter should be cleaned every 30-40
cycles, keeping the machine in operating conditions; to do this, carry out the "partial tank pump-
out" routine (program "P0")) (TANK UNL).
After cleaning the filter:
for "undercounter" models, press
for hood-type models, filling (FILL) starts automatically when the hood is closed.
Press the
button, and hold it down, until "TANK
UNL" and the duration of 2' appear on the display.
Confirm by pressing
At the end of the pump-out the word "END" flashes on
the display. The display returns to showing "P1". Clean
the filter in accordance with the instructions.
to start filling (FILL).