W O L F
G A S S U P P LY
EXPLOSION HAZARD —
Use a new CSA approved gas supply line
and install a gas shut-off valve.
Securely tighten all gas connections.
For LP gas, have a qualified technician
make sure the gas pressure does not
exceed 14" (34.9 mb) WC (water column).
Failure to do so can result in explosion,
fire or death.
IMPORTANT NOTE: The gas multi-function
cooktop must be connected to a regulated gas
supply.
IMPORTANT NOTE: This installation must
conform with local codes and ordinances. In
the absence of local codes, installations must
conform with American National Standard,
National Fuel Gas Code ANSI Z223.1 – latest
edition or CANI – B149.1 or 2.
IMPORTANT NOTE: The natural gas multi-
function cooktop (Model IM15/S) is rated for
elevations up to 8,000' (2438 m) without
adjustment. Install a high altitude kit for eleva-
tions from 8,000' (2438 m) to 10,000' (3084 m).
The LP gas multi-function cooktop (Model
IM15/S-LP) is rated for up to 10,000' (3084 m).
8
M U LT I - F U N C T I O N C O O K TO P
R E Q U I R E M E N T S
The gas multi-function cooktop is equipped for
use with natural or LP gas. It is design certified
by the Canadian Standards Association (CSA)
for natural or LP gases. The product rating
plate, located on the underside of the cooktop,
has information on the type of gas that should
be used. If this information does not agree
with the type of gas available, contact your
Wolf dealer. To obtain local dealer information,
visit the Locator section of our website,
wolfappliance.com.
The gas multi-function cooktop is supplied
1
with a
/
" NPT male gas connection at the
2
right rear corner of the cooktop.
Provide a gas supply line of
the cooktop location. A smaller size pipe on
long runs may result in insufficient gas supply.
Pipe joint compounds, suitable for use with LP
gas should be used. For LP gas, piping or
1
tubing size can be
/
" minimum.
2
If local codes permit, a new CSA design-
certified, 4–5' (1.2–1.5 m) long,
flexible metal appliance connector is recom-
mended for connecting this cooktop to the gas
supply line. Do not kink or damage the flexible
connector when moving the cooktop. The gas
1
pressure regulator has
/
" female pipe threads.
2
You will need to determine the fittings
required, depending on the size of your gas
supply line, flexible metal connector and shut-
off valve.
If rigid pipe is used as a gas supply line, a
combination of pipe fittings must be used to
obtain an in-line connection to the cooktop. All
strains must be removed from the supply and
gas lines so the cooktop will be level and in
line.
3
/
" rigid pipe to
4
1
3
/
" or
/
" ID,
2
4
8

Advertisement