Continuous:
Alarms Delay:
Alarm type:
Alarm:
Warning:
Extra run:
Condensate Drainage Menu
Condensate drainage on: Condensate drainage enabling.
Interval:
Opening time:
Functioning mode: Defines the functioning mode of condensate drainage:
Automatic:
Continuous:
Factory Menu
Oil pre-alarm:
Maximum temperature: Defines the surpassed maximum oil temperature value to generate an alarm and block the
Minimum temperature: Defines the minimum oil temperature. If the oil temperature detected is lower, an alarm sounds
Thermic drift:
Max. Press. Alarm: Defines the permitted pressure of the compressor. If surpassed, an alarm sounds and the compressor
Maximum pressure: Defines the maximum pressure value which can be set in the parameter "No Load Pressure".
Total Hours:
Loaded hours:
AN3:
INV:
Star/delta time:
Load delay:
Inverter:
Load insertion temperature: Defines the screw oil probe temperature threshold in which the loaded command solenoid
Stand-by time:
22
22
NOBEL DV 22 CSA - Cod.197EE0622ML - Rev.1 03/2019
STORM 38 VS - Cod.197DD9910 - Rev.2 01/2016
START-UP AND OPERATION
the dryer starts as soon as the compressor is switched on and will only stop when it is switched off.
Defines the delay with which the dryer alarms are displayed.
Defines the effects of the alarm on the compressor:
blocks the compressor.
warning without blocking the compressor.
Defines the time in which the dryer must continue to work, also after the compressor motor has stopped,
if the functioning mode is set to automatic.
Defines the time in which the condensate drainage solenoid valve remains closed.
Defines the time in which the condensate drainage solenoid valve must stay open.
condensate drainage only takes place when the compressor is on and in loaded mode.
condensate drainage is always on.
Defines the advance time with which an oil temperature pre-alarm should sound compared to the
maximum oil temperature.
compressor.
and the compressor is blocked.
Defines the maximum variation per second of the oil temperature. If surpassed, an alarm sounds and
the compressor is blocked.
is blocked.
Indicates the working hours of the main motor.
Indicates the working hours the compressor is loaded.
Indicates the dryer probe temperature
Indicates the inverter output automatically switches 4-20mA
Defines the duration of the star phase during start-up of the main motor of the compressor.
Defines the delay to enable the solenoid valve to command the calculated suction of the regulator from
the moment in which the motor is considered fully operational.
Sub-menu for inverter configuration (see INVERTER MENU paragraph).
valve of the suction regulator can work
Defines the stand-by time in which the compressor cannot re-start after a stoppage or a re-start of the
control unit.