Omega NOBEL 22 DV CSA Instruction & Maintenance Manual page 17

Rotary screw

Advertisement

EN
01
Support Menu
Oil hours:
Oil filter hours:
Air filter hours:
Oil separator hours: Indicates the hours remaining before the oil separator filter needs to be changed.
Bearings lubric. hours: Indicates the hours remaining before the main electric motor bearing needs to be lubricated.
Fan temperature:
No load time:
Stoppage time:
Automatic start:
Max start-up hours: Defines the maximum number of start-ups of the main electric motor within the arc of one hour. If
Remote enabling:
Fan extra time:
Inverter:
Fan temperature hysteresis: Defines the delta temperature in which the main cooling fan must work.
Diagnostic:
Input:
Output:
AN1:
AN2:
AN3:
INV:
Keeping the I key pressed, you can execute a motor start-up test. Pressing the 0 key, you can upload the default parameters
(there are 32 sets of parameters present). The Factory password is required. Press the RESET key to execute calibration of the
pressure transducer (the Factory password is required).
20
20
NOBEL DV 22 CSA - Cod.197EE0622ML - Rev.1 03/2019
STORM 38 VS - Cod.197DD9910 - Rev.2 01/2016
START-UP AND OPERATION
Start-up setting:
Start-up on
Programma 00
01
Program
02
Program
03
Program
04
Program
05
Program
Program 00
Program0
00:00 ...
....
Start time
00:00 ...
Stop time
00.0BAR.
No load pressure
00.0BAR.
Loaded pressure
Lun
Mar
Mer
Mon
Tues
Wed
Indicates the hours remaining before the oil needs to be changed.
Indicates the hours remaining before the oil filter needs to be changed.
Indicates the hours remaining before the air filter needs to be changed.
Defines the working temperature of the cooling fan. The threshold set has a hysteresis that can be
changed by 10°C. e.g. if the operating temperature is set at 80°C, the fan will activate at 80°C and stop
at 70°C (screw unit supply temperature).
Defines the motor stoppage time from the moment the load solenoid valve was deactivated because
the desired pressure was reached.
Defines the stoppage time of the compressor from the moment in which stoppage is requested using
the STOP(O) key. The solenoid valve is immediately deactivated.
If the compressor is on, it starts automatically after an electricity cut. The first start should be activated
by pressing the START (I) key on the panel.
surpassed, the compressor will stay on (loaded or with no load depending on the pressure) until the
hour is up as calculated from first start-up and then returning to normal functioning.
Remote command enabling.
Defines the time in which the cooling fan stays on after the working temperature of the compressor has
returned within the safety limits.
Sub-menu for inverter configuration (see INVERTER MENU paragraph).
Using the diagnostic menu, you can control the various inputs and outputs of the control unit:
the status of 9 digital inputs can be controlled
using the right and left keys, you can move on the relay output you want to command, while using the
up and down buttons to activate the output
Indicates pressure in bar with centesimal precision
Indicates the temperature in °C Screw probe
Indicates the temperature in °C Dryer probe
Indicates the inverter output automatically switches 4-20mA
Gio
Ven
Sab
Thurs
Fri
Sat
Enters the program
Back to previous men
Dom
Changes the parameter
Saves the program and
goes back to previous menu
Sun
Back to previous menu not
Selects the desired
program
selected
u
Selects the parameter
to change
saved