EM Moisture Recalibrate

When recalibrating an EM Moisture curve, the slope of the curve is not changed. The
entire curve shifts to match the new sample. Fine-tuning a curve is often done later in
the season as additional moisture samples are available.
CAUTION: Test Weight Recalibration must be completed before following the
steps in this section.
To adjust an M2.0 moisture calibration,
1.
Open Mirus.
2.
Go to Setup > H2 or H3 GrainGage > Moisture Curves.
3.
Select the EM moisture curve you want to adjust.
4.
Tap the edit icon
5.
Tap Recalibrate. 
5. Chamber Calibration
to save the new M2.0 calibration file.
.