Please take care when you insert the batteries for the
~
improper
insertion
may damage
the
device.
Replace
all
batteries
at one
time
(as simultaneous
set).
Use
only
1.5V
AAA
alkaline
batteries.
Use
only the size
and type
of
batteries
specified.
• When
installing
batteries,
observe
proper
+/-
polarities.
Incorrect
installation
of batteries may
cause
damage to the unit.
• Clean contacts
on
battery and
in
battery
compartment
with
a
soft,
dry cloth each time you install batteries.
• Batteries are hazardous
waste.
DO NOT dispose of them together
with
household
garbage.
• DO NOT dispose
of
batteries
in
fire. Batteries may explode or
leak.
• Recycle or dispose
of
property
in accordance
with
local, state,
province, and country
regulations.
Figure 6. Battery Installation
OPERATING GUIDE
([W\
Figure 7. Finger Position
1. Wrth the batteries in the device press
the back of the device to open the clip.
2.
Place the finger between the rubber cushions of the clip
as
shown
in Figure
7
(make sure the finger is in the right position), and then
clip the finger.
3.
Press the power button to
start
measurement.
4. DO
NOT move the finger or body during measurement.
5.
The measurement information
will
be shown directly on the display.
6.
Long
press
the button
to adjust brightness preference. Choose from
5
levels
of brightness. When in Standby mode, a short press of
the
button
will
exit it.
7.
Display viewing angle
will
change automatically according to the
direction of the hand.
A\
Fingernails and the luminescent tube
~
should be on the same side.
CARE AND MAINTENANCE
• Replace the batteries
if
the
low battery symbol
appears
on
the
display,
or
when
any
button is
pressed
and
nothing is displayed on
the
screen.
• Please
clean
the
surface of
the
device before using. Wipe
the
device
with rubbing alcohol first, let it air dry, or clean it using a soft, dry
piece
of dean fabric.
• Use rubbing alcohol to disinfect the product after use to prevent
spreading infection between uses.
• Remove
batteries when
unit is not in use
for extended
periods of time.
• The packed device can be transported by ordinary conveyance or
according to transport contract. The device cannot be transported
mixed with toxic, harmful, corrosive material.
• Storage environment of
the
device is
-40"F (-
40°C) to
+
140°F
(60°C),
<95%RH.
A\
High-pressure sterilization cannot be used on the device.
~ DO NOT immerse the device
in
liquid.
It
is recommended that the device should be kept in a dry
environment.
Htmidily may reduce the
useful life of the
device, or even damage it.
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
The Sp0
2
and pulse rate
1. The finger is not
proper-
1
.
Place the finger property
are not displayed normally
ly
positioned.
and
try
again.
2.
The user's S~ is too
2.
Try
a~ain.
Go to a hos-
low
to
be det
ed.
pita! or a diagnosis
~
you are sure the device
works all right.
2.782.465.02(HME)ESS/l.l 1.4.01.35.391 2021.08
The Sp0
2
and
pulse rate
1.
The finger is not placed
1.
Place the finger property
are not displayed S1ably
inside deep
enou\Jh.
and try again.
2. The finger is shaking or
2.
Keep the user
calm.
the user is
moving.
The device cannot be
1.
The batteries are
1.
Change
batteries.
turned on
drained or almost
2.
Reinstall
batteries.
drained.
3.
Please contact
2.
The batteries are not
Consumer
Relations.
inserted
properly.
3.
The device is
malfunctioning.
The display is off suddenly
1
.
The product will enter
1. Normal.
standby mode when no
2.
Change
batteries.
signal
is
detected within
5
seconds.
2.
The batteries are almost
drained.
SYMBOLS
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
00
Type BF
::a
WEEE
(2002/96/EC)
-
(t
Refer
to instruction
manual/booklet
IP22
Ingress of liquids
rank
%SpO,
The pulse o~gen
saturation(%
...
Manufacturer
PRbpm
Pulse rate
(bpm)
rl
Manufacture Date
~
Alarm
Inhibit
...-c
t
• 6 0' C
¥J::;~i~a~r~
1~t!C~~
The
battery
voltage
..
¢
'
CJ
indication 1s
deficient
~~~i8ll/17~l!f;~~
0
r1
(change the
battery in
time avoiding
the
inexact
measure)
1
:
~~
~~~t~~~r:iinal
-
Storage and
Transport
--
ft
Atmospheric pressure
inadequacy
limltallon
+
~~r:Wesitive
11
This side UP
-
Battery
negative
electrode
!
Fragile,
handle
with
care
···••-CJ
I. Exit standby
mode
-1
Keep
dry
2. Change brightness of
the screen
SN
Serial
number
.:-
. .
Recyclable
SPECIFICATIONS
DISPLAY INFORMATION
DISPLAY MODE
The Pulse Oxygen Saturation(SpO,)
LCD
Pulse
Rate(PR)
LCD
Pulse lntensitv (bar-araph)
LCD bar graph display
Pulse wave
LCD
Sp0
2
Parameter Specification
Measurina ranae
0%
-
100% (the resolution is
1%).
Accuracy
70%
- 100%: ±2%,
below
70%
unspecified.
Optical Sensor
Red
light (wavelength is 660
nm)
Infrared (wavelength is 905 nm)
Pulse Parameter Specification
Measuring range
30 bpm - 250 bpm (the resolution
is 1
bpm)
Accuracv
±2 born or
± 2%
select laraer
Pulse Intensity
Range
Continuous bar-graph
display,
the
higher display indicate the stronger
pulse.
Battery Requirement
1.5V
(AAA
size) alkaline batteries x 2 or rechargeable battery
Battery Life
Up to 20 hours
Dimensions and Weight
Dimensions
2.36'(L) X
1.42'
(W) X
1.26"(H)
60(L) X 36(W) X 32(H) mm
Weiaht
About 0.002 lbs (57g) w~h the batteries
APPENDIX
Guidance and manufacture's declaratio~lectromagnetic emission
for all EQUIPMENT and SYSTEMS
GUIDANCE AND MANUFACTURE'S DECLARATION-
ELECTROMAGNETIC EMISSION

Advertisement

loading

This manual is also suitable for:

Px-131coa