I
CARE OF YOUR HOME DRINKING WATER SYSTEM
PREFILTER
CARTRIDGE
- You must replace
the prefilter cartridge often to protect the RO mem-
brane from being destroyed by chlorine0 and/or from
plugging with sediments
from the water supply. If
you have chlorine in the water, replace the cartridge
at least every 6 months. If the prefilter cartridge
plugs with sediments, water flow into the RO system
drops, slowing the making of quality RO water. The
RO
membrane
may
also
begin
to
plug
with
sediments: If this happens, you may not get enough
RO water for your needs.
NOTE:
If you have the optional Electronic Monitor,
the amber "FILT"
light on the faucet base will begin
to flash
after 6 months or 900 gallons of product
water
use to tell you the filter cartridge
needs
replacing.
POSTFILTER
- Always replace the postfilterat the
same time you replace the prefilter cartridge. The
postfilter gives the product water a final filtering of
any tastes and/or odors that may remain.
TO REPLACE
THE POSTFILTER
CAUTION: BE SURE TO RELIEVE PRESSURE,
STEPS 1, 2 and 3, BO'I-I'OM OF PAGE 10.
1. Disconnect
tubing at both ends (Fig. 9).
2. Pull the filter from the holder and remove fittir,=,
from both ends.
3. Observing the flow arrow, on new filter, turn the
fittings
(use Teflon tape)
into both ends. The
elbow fitting installs at the bottom end, or outlet.
4. Replace filter into the holder and reconnect the
tubing at both ends.
vacuum
_BOTTOM
_
END
(2)
-?
_/_
clamp
postfiit_
" electroniCbox
(optional elec-
tronic monitor)
\
"AA" battedes
TO REPLACE
THE PREFILTER
CARTRIDGE
CAUTION:
BE SURE TO RELIEVE
PRESSURE,
STEPS
1,2
and 3, BOTTOM
OF PAGE 10.
IMPORTANT:
BE SURE
YOUR
HANDS
ARE
CLEAN BEFORE
WORKING
ON RO SYSTEM
IN-
TERNAL
PARTS.
1. Remove the clamp retainers and clamp sections
(Fig. 9).
2. Separate the cap from the RO housing (no need
to disconnect tubing) and set aside.
NOTE: If the cap o-ring seal remained In the
RO housing, replace it on the cap.
3. Lift the RO cartridge and prefUter cartridge from
the housing, then separate and dispose of the
prefilter cartridge.
4. Dump water remaining in the RO housing.
5. Slide the RO cartridge INTO THE TOP END of
the new prefilter cartridge, as shown in FIG. 9,
then
place into the RO housing.
NOTE: BE SURE THE BOTTOM END OF THE
PREFILTER IS AT THE BO'I-rOM, AND THE UP
({)
ARROW,
ON THE
RO
CARTRIDGE,
POINTS UPWARD.
6. Be sure the cap o-ring has lubrication (silicone
grease).
Then,
push
into position and install
clamp sections and retainers.
7. If you have
the optional
Electronic
Monitor,
replace the electronic box batteries..,
see page
12.
11

Advertisement

loading