UK - INSTALLATION – USE - MAINTENANCE ..........................16 GENERAL PRESCRIPTIONS ..................................16 DISPOSAL OF PACKING AND OF THE APPLIANCE ................................16 INSTRUCTIONS FOR INSTALLATION ................................17 REMINDERS FOR THE INSTALLER ....................................17 REFERENCE STANDARDS AND LAWS .................................... 17 UNPACKING ..........................................17 POSITIONING ..........................................
UK - INSTALLATION – USE - MAINTENANCE Do not leave de appliance unattended in presence of children and ensure that the latter do not have GENERAL PRESCRIPTIONS acces to the appliance. The appliance must be used by trained personnel. READ THIS MANUAL CAREFULLY. IT Do not leave the appliance unattended when PROVIDES IMPORTANT INFORMATION operating.
Polyethylene - PE). THE MANUFACTURER WILL NOT BE - the straps (in Polypropylene - PP). LIABLE FOR ANY DAMAGE OR INJURY RESULTING FROM FAILURE TO OBSERVING THE FOLLOWING RULES. APPLIANCE Identify the specific appliance model. The model The appliance is manufactured 90% from recyclable number is detailed on the packing and on the metals (stainless steel, aluminium sheet, copper..
If the appliance is to be be placed near walls, Convert the appliance to the local gas type, if dividers, kitchen furniture, decorative elements etc. necessary. Follow the instructions at the next this must be made of non-combustible materials paragraph “Conversion to a different type of gas”. On top appliances a rear connection is also Otherwise, they must be covered with suitable available.
CONNECTION TO THE WATER SUPPLY REPLACING THE NOZZLE AND THE MAIN BURNER PRIMARY AIR REGULATION The appliance must be connected to a potable water supply. The water inlet pressure must be Remove the control panel. between 150 kPa and 300 kPa. Use a pressure Remove the entire gas assembly (cock, gas pipe, reducer if the inlet pressure is above the maximum main and pilot burner, front combustion chamber...
before use. CHECKING THE GAS SUPPLY PRESSURE Do not leave the appliance unattended while in To measure the gas supply pressure use a operation. manometer with a minimum definition of 0,1 mbar. In the event of an appliance fault or malfunction, Remove the control panel.
Fill the well until the water is level with the MAIN BURNER IGNITION maximum level indicated on the wall of the well. Do - Turn the knob to the chosen temperature setting not use the appliance with the water level above the maximum indicated level.
The thermostat control knob has the following The control knob has the following positions of use: positions: MINIMUM TEMPERATURE SWITCHING ON - turn the knob TURNING OFF - Turn the knob to position “0”. INTERMEDIATE TEMPERATURES DRAIN THE CONTAINER TAKE To drain the container take it off from appliance.
RESULTING FROM FAILURE TO READ THIS MANUAL CAREFULLY. IT OBSERVING THE FOLLOWING RULES. PROVIDES IMPORTANT INFORMATION FOR SAFE INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE. Identify the specific appliance model. The model number is detailed on the packing and on the THE MANUFACTURER WILL NOT BE appliance dataplate.
THE MAIN BURNER DOES NOT LIGHT (EVEN AFTER REPLACING A GAS SYSTEM THOUGH PILOT IS LIT). COMPONENT, CHECK FOR GAS LEAKS AT CONNECTION POINTS. Possible causes: - Insufficient gas supply pressure. DISCONNECT THE APPLIANCE ELECTRIC - Blocked tubing or nozzle. SUPPLY, IF PRESENT, BEFORE CARRYING - Defective gas tap or valve.
REPLACING THE INFRARED HEATING ELEMENT - Remove the healting support. - Remove and replace the component. - Reassemble all parts. For assembly, proceed in reverse order. REPLACING THE HEATING ELEMENT - Pull out the control knobs, remove control panel and the container. - Disconnect the faulty heating element, remove and replace it.
VIII. TAB1 - DATI TECNICI - TECHNICAL DATA - TECHNISCHE DATEN - CARACTERISTIQUES TECHNIQUES - DATOS TECNICOS - TECHNISCHE GEGEVENS Ugelli e regolazioni - Nozzles and settings - Buses et les paramètres - Dusen und Einstellungen - Boquillas y los ajustes - Verstuivers en regelingen TAB1 UM UP _90/40 BMG...
TAB2 - DATI TECNICI - TECHNICAL DATA - TECHNISCHE DATEN - CARACTERISTIQUES TECHNIQUES - DATOS TECNICOS - TECHNISCHE GEGEVENS Categorie e pressioni - Categories and pressures - Catégories et pressions - Kategorien e Druck - Las categorías y las presiones - Categorieën en druk Pressione di allacciamento Anschlussdruck Paese Supply pressure...
Page 32
TAB3 - DATI TECNICI - TECHNICAL DATA - TECHNISCHE DATEN - CARACTERISTIQUES TECHNIQUES - DATOS TECNICOS - TECHNISCHE GEGEVENS Dati tecnici apparecchiature gas - Technical data of gas appliances - Caractéristiques techniques des appareils à gaz - Technische Daten gasgerate - Datos técnicos de los equipos de gas - Technische gegevens gasapparatuur TAB3 Consumo gas complessivo - Gasamtgasverbrauch Total gas consumption...
Page 33
TAB4 - DATI TECNICI - TECHNICAL DATA - TECHNISCHE DATEN - CARACTERISTIQUES TECHNIQUES - DATOS TECNICOS- TECHNISCHE GEGEVENS Dati tecnici apparecchiature elettriche - Dati tecnici aTechnical data of electric appliances - Caractèristiques techniques des appareils electriques - Technische Daten Elektrogerate - Datos técnicos de los equipos eléctricos - Technische gegevens elektrische apparatuur TAB4 Potenza totale...