Check
Outdoor
code
LED display
[P26]
[P29]
No code
Check and troubleshooting
(Item without special mention Indicates part of outdoor unit.)
[Short-circuit of compressor driving elements]
Are connections of compressor
lead and reactor lead correct?
(Check referring to Wiring diagram.)
YES
Does the same error occur in
operation without compressor lead?
NO
[Position detection circuit error]
Check outdoor P.C. board.
Defect → Replace
[Other] Compressor disorder due to sudden change of load, etc.
∗ Although the display of outdoor LED outputs, the unit automatically restarts
and error is not determined.
∗ A code may appear when an open phase of compressor, coming-out of wires or
power relay trouble occurred.
- 67 -
NO
Correct wiring.
YES
Replace outdoor P.C. board.
Check compressor. (Layer short, etc.)
Defect → Replace