(print, photocopy, microfilm or in any other process) without the express permission. We reserve the right to make changes in the content without notice. The SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in the handbook and assumes no responsibility for damages that occur...
Page 3
S-DIAS SDCI MASTER MODULE IIO 041 S-DIAS SDCI Master Module IIO 041 with 4 SDCI ports and 4 digital inputs The S-DIAS Single-Drop Digital Communication Interface (SDCI) master module enables the connection of up to 4 intelligent SDCI sensors or SDCI actuators in compliance with the SDCI specification V1.1 according to IEC61131-9.
IIO 041 S-DIAS SDCI MASTER MODULE Contents Technical Data ...............12 SDCI Interface Specifications ............ 12 SDCI Interface as a Digital Output ..........12 SDCI Interface as a Digital Input ..........13 Digital Input Specifications ............13 Electrical Requirements ............. 14 Voltage Monitor ................
Page 5
S-DIAS SDCI MASTER MODULE IIO 041 6.1.1 Communication Interfaces ..............28 Global Methods ................28 6.2.1 GetEvent ................... 28 6.2.2 Data structure t_SDCIEventDetails ........... 28 Internal Properties ..............30 6.3.1 Behavior Asynchronous Communication (SDOs) ......30 6.3.2 Behavior SDCI Device at Project Start ..........30 6.3.3...
Page 6
General knowledge of automation technology is required. Further help and training information, as well as the appropriate accessories can be found on our website www.sigmatek-automation.com. Our support team is happily available to answer your questions. Please see our website for our hotline number and business hours.
Page 7
S-DIAS SDCI MASTER MODULE IIO 041 Basic Safety Directives Symbols Used The following symbols are used in the operator documentation for warning and danger messages, as well as informational notes: DANGER Danger indicates that death or serious injury will occur, if the specified measures are not taken.
Page 8
IIO 041 S-DIAS SDCI MASTER MODULE INFORMATION Information Provides important information on the product, handling or relevant sections of the documentation, which require attention. Page 6 26.07.2023...
Page 9
It does not guarantee properties under the warranty. Please thoroughly read the corresponding documents and this operating manual before handling a product. SIGMATEK GmbH & Co KG is not liable for damages caused through, non-compliance with these instructions or applicable regulations.
Page 10
IIO 041 S-DIAS SDCI MASTER MODULE General Safety Directives The Safety Directives in the other sections of this operating manual must be observed. These instructions are visually emphasized by symbols. INFORMATION According to EU Directives, the operating manual is a component of a product.
Page 11
S-DIAS SDCI MASTER MODULE IIO 041 CAUTION Handle the device with care and do not drop or let fall. Prevent foreign bodies and fluids from entering the device. The device must not be opened! Manipulez l’appareil avec précaution et ne le laissez pas tomber.
Page 12
The product was constructed in compliance with the following European Union directives and tested for conformity. 3.1.1 EU Conformity Declaration EU Declaration of Conformity The product IIO 041 conforms to the following European directives: • 2014/35/EU Low-voltage Directive • 2014/30/EU Electromagnetic Compatibility (EMC Directive) •...
Page 13
S-DIAS SDCI MASTER MODULE IIO 041 Type Plate HW: Hardware version SW: Software version 26.07.2023 Page 11...
IIO 041 S-DIAS SDCI MASTER MODULE Technical Data SDCI Interface Specifications Number of interfaces Specification version SDCI V1.1 Data transfer rate 4.8 kbit/s, 38.4 kbit/s, 230.4 kbit/s SDCI supply 24 V (via power switch, short-circuit proof) SDCI supply current maximum 500 mA per connection...
S-DIAS SDCI MASTER MODULE IIO 041 SDCI Interface as a Digital Input Input voltage typically +24 V maximum +30 V Signal level low: < +8 V high: > +14 V Switching threshold typically +11 V Input current 6.8 mA at +24 V Input delay typically 0.5 µs...
IIO 041 S-DIAS SDCI MASTER MODULE Electrical Requirements External +24 V supply +18-30 V DC Current consumption external typically 20 mA at +18 V maximum 25 mA at +18 V +24 V supply without actuators or typically 23 mA at +24 V...
S-DIAS SDCI MASTER MODULE IIO 041 Voltage Monitor Supply voltage supply voltage > 18 V (corresponding DC OK-LED lights green) +24 V SDCI Miscellaneous Article number 20-104-041 Standard UL 508 (in preparation) Environmental Conditions Storage temperature -20 ... +85 °C Environmental temperature 0 ...
S-DIAS SDCI MASTER MODULE IIO 041 Connector Layout INFORMATION The connections of the +24 V supply (X5: pin 1 and pin 2) or the GND supply (X5: pin 3 and pin 4) are internally bridged. To supply the module, only one connection to a +24 V pin (pin 1 or pin 2) and a GND pin (pin 3 or pin 4) is required.
IIO 041 S-DIAS SDCI MASTER MODULE Status LEDs Module Status green module active no supply available BLINKING (5 Hz) no communication User yellow can be set from the application (e.g. the module LED can be set to blinking through the...
S-DIAS SDCI MASTER MODULE IIO 041 Applicable Connectors Connectors: X1-X5: Connectors with spring terminals (included in delivery) The spring terminals are suitable connecting ultrasonically compacted (ultrasonically welded) strands. Connections: Stripping length/Sleeve length: 10 mm Mating direction: parallel to the conductor axis or circuit board Conductor cross section rigid: 0.2-1.5 mm...
IIO 041 S-DIAS SDCI MASTER MODULE Label Field Manufacturer Weidmüller Type MF 10/5 CABUR MC NE WS Weidmüller article number 1854510000 Compatible printer Weidmüller Type Printjet Advanced 230V Weidmüller article number 1324380000 Page 20 26.07.2023...
Page 25
S-DIAS SDCI MASTER MODULE IIO 041 Assembly/Installation Check Contents of Delivery Ensure that the contents of the delivery are complete and intact. See chapter 1.3 Contents of Delivery. INFORMATION On receipt and before initial use, check the device for damage. If the device is damaged, contact our customer service and do not install the device in your system.
IIO 041 S-DIAS SDCI MASTER MODULE Mounting The S-DIAS modules are designed for installation into the control cabinet. To mount the modules a DIN-rail is required. The DIN rail must establish a conductive connection with the back wall of the control cabinet. The individual S-DIAS modules are mounted on the DIN rail as a block and secured with latches.
Page 27
S-DIAS SDCI MASTER MODULE IIO 041 Recommended minimum distances of the S-DIAS modules to the surrounding components or control cabinet wall: a, b, c … distances in mm (inches) 26.07.2023 Page 25...
Hardware Class IIO041 for the 4-port S-DIAS master module II041 This hardware class is used to control the the IIO 041 hardware module with 4 ports, which can be used as either a connection for SDCI devices (Single Drop Communication Interface), 24 V digital inputs or 24 V digital outputs.
S-DIAS SDCI MASTER MODULE IIO 041 10.1 General Class State State Shows the actual status of the hardware class Device ID State Shows the Device ID of the hardware module FPGA Version State FPGA version of the module in 16#XY (e.g. 16#10 = version 1.0)
IIO 041 S-DIAS SDCI MASTER MODULE 10.1.1 Communication Interfaces ALARM Downlink With this downlink the corresponding alarm class can be placed via the hardware editor. 10.2 Global Methods 10.2.1 GetEvent If the EventsAvailable server shows that master events are available, these can be retrieved via the GetEvent method.
Page 31
S-DIAS SDCI MASTER MODULE IIO 041 EventCode : t_EventCode UINT enumeration, which contains the default error codes (each manufacturer can additionally define their own codes) E_EVENT_NO_MALFUNCTION (0) E_EVENT_GENERAL_MALFUNCTION (4096) E_EVENT_EXCESS_AMBIENT_TEMPERATURE (16656) E_EVENT_TOO_LOW_AMBIENT_TEMPERATURE (16672) E_EVENT_EXCESS_DEVICE_TEMPERATURE (16912) E_EVENT_TOO_LOW_DEVICE_TEMPERATURE (16928) E_EVENT_EXCESS_PERIPHERY_TEMPERATURE (17168) E_EVENT_TOO_LOW_PERIPHERY_TEMPERATURE (17184)
IIO 041 S-DIAS SDCI MASTER MODULE 10.3 Internal Properties 10.3.1 Behavior Asynchronous Communication (SDOs) The asynchronous communication of the SDCIDevices (e.g. SDCIDevice_AsyncPara) is managed by the SDCI master class (e.g. IIO041). It has only one asynchronous channel to the module and can therefore only process the asynchronous accesses in sequence. This means, for example, if the SDCI device communicates asynchronously on port 1, it is blocked on the other ports for this period.
Page 33
S-DIAS SDCI MASTER MODULE IIO 041 11 Transport/Storage INFORMATION This device contains sensitive electronics. During transport and storage, high mechanical stress must therefore be avoided. For storage and transport, the same values for humidity and vibration as for operation must be maintained! Temperature and humidity fluctuations may occur during transport.
Page 34
IIO 041 S-DIAS SDCI MASTER MODULE 13 Maintenance INFORMATION During maintenance as well as servicing, observe the safety instructions from chapter 2 Basic Safety Directives. 13.1 Service This product was constructed for low-maintenance operation. 13.2 Repair INFORMATION In the event of a defect/repair, send the device with a detailed error description to the address listed at the beginning of this document.
Need help?
Do you have a question about the IIO 041 and is the answer not in the manual?
Questions and answers