Download Print this page

Packaging Contents; Tools Required For Installation; Installation Instructions - Fellowes Array AR1 Install Manual

Hide thumbs Also See for Array AR1:

Advertisement

Available languages

Available languages

PACKAGING CONTENTS

• Air Purifier (1X)
• Hybrid Filters w/ Pre-Filter (1X)
• 16ft mounting cables with clutches (4X)

TOOLS REQUIRED FOR INSTALLATION

• Gloves
• Ladder/Step Stool
• UL Elbow or Conduit
• Wire Nuts
• Level
• Tape
NOTE:
Three people are recommended for easy and proper installation
NOTE:
We recommend removing adjacent ceiling tiles for
easiest installation
NOTE:
It is required to remove one cross-tee in the ceiling grid, which will
make installation much easier

INSTALLATION INSTRUCTIONS

1
Before beginning installation, ensure that a
qualified electrician has run a 120V circuit
to the installation area. Remove unit from
packaging and stage on a tabletop or other
surface under or near installation area with
door facing upwards.
2
• Centering Blocks (4X)
• User Manual (1X)
• Unobstructed 24" x 24" drop ceiling grid with at least 24" clearance above
the drop ceiling
• Mounting hooks or location installed to local code and capable of holding
the weight of the system
• For ease of installation and optimal placement of unit in the grid, it is
HIGHLY RECOMMENDED that either hooks be drilled into the ceiling, or strut
channels be used to loop cables if there are no existing mounting points
available above the perimeter of the housing.
NOTE
NOTE
2
Open unit door by depressing the latch button
and pulling upward. Have one person hold the
door open for the next few steps or the hinges
can be damaged.
NOTE: do not remove corrugate support trays
attached to door yet.
: Do not install next to a return or register
: Shut off circuit breaker to installation area before
beginning installation
3
Disengage the filter clamp lever until a click
is heard.
ENGLISH

Advertisement

loading