Ossila L2002A2 User Manual

Uv ozone cleaner
Hide thumbs Also See for L2002A2:

Advertisement

Quick Links

UV Ozone Cleaner
User Manual
Manual version 2.0.G
Product code: L2002A2
Product Version: 2.0
Software Version: 2.0
enabling materials science
Ossila.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L2002A2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ossila L2002A2

  • Page 1 UV Ozone Cleaner User Manual Manual version 2.0.G Product code: L2002A2 Product Version: 2.0 Software Version: 2.0 enabling materials science Ossila.com...
  • Page 2: Table Of Contents

    Operational Safety ............................... 21 Maintenance ..............................23 Cleaning ..................................23 Repair & Service ................................23 Storage Conditions ..............................23 10. UV Ozone Cleaner Troubleshooting ......................24 11. List of Related Products ..........................25 12. Revision History............................26 Ossila.com Ossila Limited © 2023...
  • Page 3: Overview

    Surface cleaning • Preparation for thin-film deposition and surface treatment • Ultraviolet curing • Removal of surface monolayers • Surface oxidation • Contaminants Photoresist • Resins • Cleaning solvent residues • Plastic surface/silicon oil residues • Ossila.com Ossila Limited © 2023...
  • Page 4: Eu Declaration Of Conformity (Doc)

    Telephone number: +44 (0)114 2999 180 Email Address: info@ossila.com declare that the DoC is issued under our sole responsibility and belongs to the following product: Product: UV Ozone Cleaner (L2002A2) Serial number: L2002A2-xxxx Object of declaration: UV Ozone Cleaner (L2002A2)
  • Page 5 EU-harmoniseringslovgivning, på den/de foregående side(r) i dette dokument. [Deutsch] EU-Konformitätserklärung Hersteller: Ossila Ltd., Solpro Business Park, Windsor Street, S4 7WD, Vereinigtes Königreich erklären in alleiniger Verantwortung, dass das aufgeführte Gerät konform der relevanten EU-Harmonisierungsgesetzgebung vorangegangenen Seiten dieses Dokuments ist.
  • Page 6 [Por tuguês] Declaração de Conformidade Fabricante: Ossila Ltd., Solpro Business Park, Windsor Street, S4 7WD, Reino Unido Declara exclusiva responsabilidade que o equipamento indicado está em conformidade a legislação de harmonização relevante da UE mencionada na(s) página(s)
  • Page 7: Safety

    Mains inlet rated for 230V ± 10%. For 110V mains supplies, use the transformer supplied • Do not cover the ventilation slots • If the lamp breaks, leave the room ventilating for at least 15 minutes & contact Ossila • The unit must be connected to a grounded power outlet •...
  • Page 8: General Hazards

    Ensure the power is disconnected to avoid the risk of electrocution. • Leave the room under ventilation for at least 15 minutes. • Using cut-resistant gloves, collect any stray glass pieces in a sealed • container and close it tightly. Ossila.com Ossila Limited © 2023...
  • Page 9: Power Cord Safety

    Servicing If servicing is required, please return the unit to Ossila Ltd. The warranty will be invalidated if: Modification or service has taken place by anyone other than an Ossila engineer. The Unit has been subjected to chemical damage through improper use.
  • Page 10: Health And Safety - Servicing

    Health and Safety – Servicing Service or installation work that includes integrating electrical components should only be performed by an Ossila engineer. Never alter the wiring of any purchased equipment. If changes are made, such alterations may damage the equipment, cause injury, or death.
  • Page 11: Damage Inspection

    The UV lamp is a mercury vapour lamp. The consumer may be exposed to mercury only if the glass of the lamp is cracked or broken. If this happens, please contact Ossila after abiding by these rules to minimise exposure: 1.
  • Page 12: System Components

    UV Ozone Cleaner unit (Figure 6.1). • Power supply cord (Figure 6.2). The UV Ozone Cleaner unit is powered by 230V, 50/60Hz • supply, Countries with a 110V power supply are supplied with an additional power transformer. Ossila.com Ossila Limited © 2023...
  • Page 13: Installation

    UV Ozone Cleaner User Manual Figure 6.1. Ossila’s UV Ozone Cleaner. Figure 6.2. Main power cord adapter. Plug shown is for United Kingdom; the UV Ozone Cleaner ships with a suitable plug for the country of purchase. Installation 1. Place the unit on a solid, level surface inside a fume cupboard.
  • Page 14: Operating The Uv Ozone Cleaner

    UV Ozone Cleaner Overview A top-down view of the UV Ozone Cleaner is shown in Figure 8.1, with all the relevant components highlighted. Figure 8.2 shows the power cord socket, fuse socket, and the power switch. Ossila.com Ossila Limited © 2023...
  • Page 15 Durable metal casing Simple keypad for Clear LCD display programming Internal safety interlock Tray to place the prevents the lamp being on substrate when tray is open Figure 8.1. UV Ozone Cleaner front panel image. Ossila.com Ossila Limited © 2023...
  • Page 16: Uv Ozone Cleaner User Interface

    UV Ozone Cleaner User Interface Figure 8.3 shows the front panel of the UV Ozone cleaner, where the function of each of the keypad buttons is explained in Table 8.1. Figure 8.3. UV Ozone Cleaner LCD screen and keypad. Ossila.com Ossila Limited © 2023...
  • Page 17: Practical Operation

    4. Once the program has finished, open the tray door and remove your sample. Program Operation WARNING! High voltage The UV lamp can operate at a maximum of 4000 V. Avoid any electrical cables or solvents around the UV Ozone Cleaner. Ossila.com Ossila Limited © 2023...
  • Page 18 During the bootup time, the user can enter the buzzer setting and temperature reading menu screens for the UV Ozone Cleaner. Press and hold both single-increment second buttons (up and down) at the same time to see the temperature readings display as in Table 8.2. Ossila.com Ossila Limited © 2023...
  • Page 19 3. To exit the Settings page, press the START button to proceed to the Caution page. 4. The user must read the instructions and press START to enter the main screen of the UV Ozone Cleaner as shown in Figure 8.5. Ossila.com Ossila Limited © 2023...
  • Page 20 When the Elapsed time matches the Set Time, the one-note buzzer will sound - indicating the program has finished. While the program is running, the user can stop the program by pressing the III. STOP button. This will also reset the Set Time to 00:00. Ossila.com Ossila Limited © 2023...
  • Page 21: Operational Safety

    (II) High Temperature Safety Warning If one or more of the internal temperature sensors reads above certain temperature value, a high temperature warning will appear on the screen. Table 8.4 shows the different warnings for this Ossila.com Ossila Limited © 2023...
  • Page 22 8.9 will appear and the user is required to restart the unit. The error code that is displayed indicates which sensor is in error and is used for troubleshooting. Table 8.4. High temperature warning. Warning Display HIGH TEMP (> 50°C) VERY HIGH TEMP (> 65°C) Ossila.com Ossila Limited © 2023...
  • Page 23: Maintenance

    There are no user-serviceable parts in this unit except for the fuse which is accessible externally. If the unit is faulty, return it to Ossila Limited. Our service department will promptly quote to repair any faults that occur outside the warranty period.
  • Page 24: 10. Uv Ozone Cleaner Troubleshooting

    The fuse on the rear panel has blown has blown, replace with a suitably rated 1A slow blow fuse Contact Ossila for a replacement power The power supply adapter has a fault supply adapter If all the above causes have been...
  • Page 25: 11. List Of Related Products

    ITO Substrates Pre-patterned ITO OFET Substrates (S161/S162) (e.g. S111) The Ossila ITO OFET substrates have been designed to enable All of our 15 x 20 mm ITO substrates for OPV, OLED and fabrication and characterisation without the need for vacuum sensing applications.
  • Page 26: 12. Revision History

    Feb 2018 Change company’s address Jul 2018 Add languages in DoC and updated formatting Aug 2018 Removed Warranty Information; Updated formatting Dec 2018 Minor corrections, update images Sept 2020 DOC update, addition of servicing caution Ossila.com Ossila Limited © 2023...

Table of Contents