De2 or De4 Fog Generator Table of content Section Page Table of content User Guide How to read this User Guide Qualified Personnel Need a little Help? Copyright Notice Basic description Pre-Install Environmental Requirements Electrical Requirements Tubing Requirements Unpacking Installing the De2 or De4...
De2 or De4 Fog Generator User Guide Congratulations! You are now in possession of a MDG De2 or De4 Fog Generator. We hope this Fog Generator will bring you long hours of satisfaction. Please read the following instructions carefully and completely before installing your Fog Generator and turning it on.
Need a little Help? At MDG, we try our best to provide you with complete information for our products. Despite our best efforts, sometimes, a little more is required due to the specifics of your project and installation. We’re looking forward to go that extra mile for you.
LCD, in the Status Menu. Check the FAIL State and Troubleshooting paragraphs for diagnostics. When « Fog On » mode is activated, the MDG Fog Generator will produce fog for as long as the ready level is reached (temperature) and all other control parameters are within specifications. When « Fog On » mode is deactivated, the APS™...
Page 7
De2 or De4 Fog Generator Access door Fog output nozzles Control Input / Output Fog fluid input AC Input or N Gas input 50 psi ± 5% Heating module - De2 : 2 nozzles - De4 : 4 nozzles Heater Control...
De2 or De4 Fog Generator Pre-Install Environmental Requirements • 0 ºC to 50 ºC (32 ºF to 122 ºF) operating temperature • 2 m (6.5 ft) clearance on all sides and in front of the equipment required. • Wall-mounting hardware (not provided) must support 22.4 kg (49.2 lb) on four suspension points (see Dimensions paragraph).
Upon arrival, carefully inspect the containers for any shipping damage. CAUTION If ANY damage is found, immediately report it to the freight service and to MDG Fog within 24 hours. When opening the container, ensure that you do not damage the exterior finish of the enclosure. Save all packing material for eventual equipment factory return.
Installing the De2 or De4 Careful planning must be used when selecting the location to mount the equipment: • The De2 or De4™ can be installed indoor or outdoor, away from heavy dust or any harsh environment situations. • Ensure there is enough space for all conduit and tubing runs. Where possible, mount the De2 or De4™...
Page 11
De2 or De4 Fog Generator If the fog generators are positioned at a higher elevation than the PFR (more than 3 meters) or if the distance is over 100 meters, you may be obliged to separate the gas line for the fog generators, and increase the pressure of the PFR to compensate the pressure of the fluid column (elevation) or the pressure drop due to friction (see also the PFR User Guide).
Gas input on the Fluid input STEP 3: AC Power cable On the bottom side of the De2 or De4 Fog generator, insert the AC cable, and then connect it to the internal terminal. Live line L1 (brown) Neutral line N / L2 (blue) Do not forget to connect the ground to the chassis.
Page 13
STEP 5: Connect the Modbus cable (if required) MDG Products are using Modbus RTU protocol over RS-485 in 2 wire transmission mode (half-duplex). In this mode, TXD+ and RXD+, on the Master device, are wired together to TXD+ and RXD+ on the Slave device(s).
De2 or De4 Fog Generator Working with the Fog Generator The MDG De2 or De4 Fog Generator is quite easy to operate and requires no preventive maintenance. Switch On the power. The MDG Fog generator will display, on the LCD, during four (4) seconds, the following message:...
De2 or De4 Fog Generator The Keyboard The user can scroll in the menu by using the buttons of the keyboard: ‘Down’ moves the selection to the next menu, or decrease a data value. • When at the end of a list, the program moves back to the first item of this list.
Status Menu summarizes all the state of the fog generator. None of its sub menus can be modified. • Control Menu allows the user to control locally the MDG De2 or De4. All its sub menus can be set, as long as the generator is not in Modbus or PLC mode.
Page 17
De2 or De4 Fog Generator The tree menu architecture is explained below. Items highlighted in blue are state menu ( - ), and those highlighted in yellow are control menu ( ). STATUS Status menu STATE ---- Status State...
Page 18
De2 or De4 Fog Generator INTERFACE Modbus Menu Communication toggle COMM. ---- LOCAL - the generator is controlled by the keyboard ONLY - the generator is controlled by MODBUS ONLY MODBUS - the generator is controlled by PLC (In/Out) ONLY...
EEPROM memory. At this point, the MDG De2 or De4 switches to stand-by mode, and most of the electronic controls are off. When the generator is manually switched to «UNIT ON» mode («CONTROLUNITON»), the program starts the heating cycle («STATUSSTATE = % HEAT»), which will last approximately 7 to 8 minutes.
FAIL state mode is initiated if any critical error occurs. In this state, the MDG De2 or De4 is off, awaiting an action from the user. A critical error is always displayed in the Status Menu («STATUSERROR»), as well as the five (5) last critical errors («STATUSLAST ERR»),...
Page 21
De2 or De4 Fog Generator • ERROR = T. HIGH LAST ERR CODE = 4 This error will occur if the temperature of the heating module is too high. This is generally due to an electronic problem. Shut down the generator and restart it.
The input Channels are ON when the control signal is at a high level («Active High»). The Output Channels are activated, when the output signal is at a high level («Active High»). The MDG De2 or De4 provides a fast way to check the communication mode: PLC Mode...
• You need to integrate a flow code in your system to be able to discuss with the MDG De2 or De4, This can be as simple as few buttons and control lights on a console up to a full Web HMI via a phone.
Page 24
De2 or De4 Fog Generator The MDG De2 or De4 Fog Generator acts as a MODBUS slave and any transmitted bytes are interpreted according to MODBUS specification (www.modbus.org). Data is transmitted in packets, so-called frames, with a maximum of 256 bytes in length.
Page 25
De2 or De4 Fog Generator The Modbus block parameters implemented in the MDG De2 or De4 Fog Generator are summarized in the following table: Read Command Data Access Address Type Size Scale Unit Description Write Status 000001 bool R / W...
De2 or De4 Fog Generator Bootloader The MDG De2 or De4 Fog Generator uses a BootLoader, also called boot manager. This program is a firmware (software embedded in a hardware device) located into the non-volatile memory of the microcontroller unit (MCU) that allows in-circuit reprogramming of the device using its USB communication port.
Depressurize the fluid reservoir by turning off the pressure switch. Wait 2 minutes for complete depressurization of the fluid reservoir. • Now, unscrew the brass closure located on top of the fluid reservoir and slowly pour the MDG Neutral Fog Fluid until it reaches the inside bottom of the opening. •...
De2 or De4 Fog Generator Troubleshooting Contact MDG if symptoms are not listed, or if the provided solutions fail to resolve the issue. Table 2: Symptoms and Solutions Symptoms Probable Causes and Suggested Actions • Verify that AC power cord is properly connected The fog generator does not switch on on both ends.
Page 29
De2 or De4 Fog Generator Symptoms Probable Causes and Suggested Actions • If you are in Modbus mode: • Verify the cable • Verify the Modbus Slave address and the patch • Verify Baudrate, and parity • ERROR = P. LOW «...
Page 30
De2 or De4 Fog Generator Symptoms Probable Causes and Suggested Actions • ERROR = T. HIGH • Restart the generator. This is generally due to an electronic problem. • ERROR = T. SAF • Restart the generator. This is generally due to an electronic or sensor problem.
Particle size: 0.5 to 0.7 microns Fluid consumption: De2: 1.2 L (0.31 US gal.) per hour at 345 kPa / 50 psi De4: 2.4 L (0.62 US gal.) per hour at 345 kPa / 50 psi Fluid type: MDG Neutral...
MDG or one of its authorized service centres, or if it is used under conditions for which it has not been designed, or if any other fluid than the MDG Neutral Fog Fluid has been used. MDG Fog Generators Ltd is not responsible for any damages resulting from a faulty installation or from abusive use of the product.