  • Page 1 Podiatry Couch MOON Instructions for Use 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 Revision status 30/11/2023...
  • Page 2 © 2023 Hellmut Ruck GmbH. All rights reserved. This document must not be copied, edited, reproduced or translated without the prior written permission of Hellmut Ruck GmbH. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 3 RUCK. Tested and approved as a Class  1 medical product, the podiatry couch can bear loads of up to 250 kg. The MOON series thanks its unique char- acter to the moulded wood elements, which can be selected in a walnut CPL, oak CPL or white CPL finish.
  • Page 4: Table Of Contents

    3.5 Hazards due to the use of several podiatry couches operated with wireless foot controls .................. 19 3.6 Hazards due to inadequate disinfection..........19 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 5 Additional functions of memory buttons 1 and 4: Initialisation ..................34 5.1.4 Additional functions of memory buttons 2 and 3: Resetting the memory positions ............ 34 5.1.5 Short-stroke keys ................35 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 6 5.10.2 Folding down the calf support and footrest ....... 48 5.10.3 Extending the footrest ..............49 5.10.4 Shifting the footrests horizontally ..........50 5.10.5 Removing the magnetic calf supports ......... 50 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 7 6.7 Spare parts ..................... 59 6.8 Disposal ......................59 7 Technical specifications................60 General data ....................60 7.2 Electromagnetic interference emission ..........61 7.3 Electromagnetic immunity ................. 61 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 8: About These Instructions

    Medical product Observe the disposal notice! Application part, Type B Manufacturing date CE conformity marking UKCA conformity marking Refer to the instructions for use Manufacturer 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 9: Meaning Of Signal Words

    Please make sure to observe the applicable national regulations and laws in the country or region of use. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 10: Product Description

    Hand wheel for rotation Neck cushion Calf support Back cushion Footrest Armrests 10 Clamp lever – footrest Armrest cushion (optional) Seat cushion 11 Levelling pad 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 11 13 Release mechanism for 16 Lifting system gas-pressurised spring 17 Base plate (optional) 18 Mains cable 14 Electrical height adjustment 19 Transport lock for footrest (optional) 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 12 Product description 20 Manual control (optional) 21 Foot control plug connector (optional) 22 Foot control, wired (optional) 23 Wireless foot control (optional) 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 13: Functionality

    If the device is not used as intended, all liability is excluded and the warranty is rendered null and void. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 14: Prerequisites And Qualifications Of Operators

    Make sure that the relative humidity does not fall below 30%. If the floor is made of synthetic material and the humidity is too low, electro- static discharges could affect the functioning of the unit. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 15: Basic Safety Instructions

    Use the supplied levelling pads to ensure the couch is in a stable and secure position. DANGER Do not operate the podiatry couch in rooms containing flammable or explosive substances. Danger of fire or explosion! 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 16: Hazards Due To Overloading Or Improper Operation

    Do this by disconnecting the mains plug, switching off the power socket or locking the treatment room whenever you are not carrying out a treatment. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 17: Electromagnetic Disturbances - Requirements And Tests

    The operator may need to take remedial action, such as relocating or repositioning the couch. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 18: Hazards Due To Modifications To The Device

    Contact RUCK Service immediately to have any identified defects remedied as quickly as possible. Only operate the podiatry couch again after all defects have been eliminated or after consultation with the manufacturer. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 19: Hazards Due To The Use Of Several Podiatry Couches Operated With Wireless Foot Controls

    Disinfect the podiatry couch after each treatment. Insufficient disin- fection can lead to transmission of disease. Observe the requirements of the responsible national body for hygiene and disinfection. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 20: Transport And Start-Up

    Connect the podiatry couch with the provided mains cable (rolled cable length: 180 cm / 5.9 ft) to a power socket with a protective earth contact. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 21: Unloading And Setting Upright

    If you change the position or lean of the podiatry couch without trans- port lock, parts of the couch can be deformed or broken. We do not assume any liability or warranty for this. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 22: Setting Upright

    You risk harming your health. To protect the base plate, place a protective mat (e.g. foot mat) in front of the pallet to which the couch is attached. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 23 Turn the podiatry couch 180° so that the foot supports do not come into contact with the pallet when lowering. To do this, open the hand wheel for rotation. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 24 Grip the two armrest mountings on the right/left of the backrest as shown. Lift the podiatry couch and have a second person place two levelling pads under the floor plate. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 25 Grip the two armrest mountings on the right/left of the backrest as shown. Lift the podiatry couch and have a second person place two levelling pads under the floor plate. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 26 Use an Allen key to loosen the hexagon socket screw on the right/left and remove with the corresponding washer. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 27 In order to do so, follow points 8 - 10 in the reverse order. Changing the position of the couch without using the transport locks can damage the couch. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 28: Mounting The Headrest

    Transport and start-up Mounting the headrest Appearance after unpacking Podiatry couch with mounted headrest 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 29: Mounting The Armrests

    Without levelling, unwanted shifting of the couch could present a danger to people. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 30: Preparing For Start-Up

    Before switching on for the first time: Make sure the transport locks have been removed. Otherwise, the backrest cannot move. Drive motors can become damaged. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 31: Connect To The Mains Power Supply

    Make sure the mains plug is easily accessi- ble or use a socket that can be switched off. * If present. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 32: Operation And Use

    Press a memory button and hold the button down to bring the podiatry couch to a saved position. The drives will only run as long as the button is held down. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 33 Tap the button 2  times in quick succession and then hold the button down to tilt the two elements forwards. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 34: Additional Functions Of Memory Buttons 1 And 2: Button Lock

    Press memory buttons 2 and 3 at the same time and hold the buttons for at least 10  sec- onds in order to reset all memory positions to the factory default settings. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 35: Short-Stroke Keys

    A beep sounds at the same time. Battery change: see page 57. Profile key – Operator a Profile key – Operator b Profile key – Operator c 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 36 Press a profile key to activate that operator. When a profile key is pressed, the corresponding LED lights up for 2 seconds. The respective positions can be moved to using the memory buttons. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 37: Saving Memory Positions

    Press the key for the desired profile a, b or c simultaneously with the desired memory button. When 2 beeps sound, the memory position has been saved. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 38: Wireless Foot Control: Pairing With The Control Unit

    This prevents the foot control from being accidentally paired with the wrong couch. Key/button combination for pairing mode 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 39 To do this, label the wireless foot controls and the corresponding couches. Test the assignment before you treat a person. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 40: Control Elements On The Manual Control

    This brings the seat back into home position. Height adjustment Press key  5 to raise the seat upwards. Press key 6 to lower the seat downwards. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 41 Press the desired memory key and hold the button down for 3  seconds. When the beep sounds, the memory position has been saved. The LED of the selected operator remains constantly lit again. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 42: Additional Functions Of Memory Keys 7 And 10: Initialisation

    2 beeps. All LEDs light up: The button lock is now active. Deactivate the key lock by pressing and holding both keys again until you hear 2 beeps. The button lock is now deactivated again. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 43: Plug Connector For The Manual Control And The Wired Foot Control

    Check the correct alignment of the plug connector when connecting the switch: the green markings of both connectors must be lined up together; see the illustration. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 44: Adjustment Options For The Headrest

    Adjusting the backrest using the patient switch The patient can use the patient switch 1 to adjust the backrest to a personally comfortable position. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 45: Turning The Seat

    Changing the position of the hand wheel When the hand wheel is released, the hand wheel itself can be moved to a different position. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 46: Changing Sides Of The Hand Wheel

    Use a screwdriver to unscrew the two marked slotted screws. Position the hand wheel on the side in area A or B. Tighten the two slotted screws again. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 47: Armrests

    Both armrests can be folded back: folded back position is for getting in and out of the couch. Folded down position is for resting the arms. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 48: Calf Support And Footrest

    This position will be reliably held by the gas pressure springs. Optionally the footrest of the podiatry couch can by tilted by motor 2. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 49: Extending The Footrest

    Otherwise, the footrest could drop down uncontrollably. Make sure the footrests are always retracted before lowering the seat. Otherwise, they could be damaged by pushing against the base plate. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 50: Shifting The Footrests Horizontally

    Operation and use 5.10.4 Shifting the footrests horizontally 5.10.5 Removing the magnetic calf supports 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 51: Maintenance And Warranty

    RUCK Service HELLMUT RUCK GmbH Daimlerstr. 23 75305 Neuenbürg, Germany Phone +49 (0)7082 944 2 255 +49 (0)7082 944 2 259 email after-sales@hellmut-ruck.uk www.hellmut-ruck.uk 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 52: Maintenance By Operator

    Do this by disconnecting the mains plug or switching off the power socket. Danger of electric shock if liquid gets into the couch. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 53 We do not assume any warranty for surface discolourations that are attributable to the use of aggressive liquids (e.g. propolis, tea tree oil, chlorinated cleaners or similar products). 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 54: Disinfecting And Cleaning Contact Surfaces

    1 minute for bacteria or 5 minutes for fungi. You will find more instructions on the disinfectant. Always allow the surface to air-dry. Do not try to wipe the surface dry. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 55: Cleaning Leatherette Cushions

    (see the section Replacing cushions). - Cushion complete set for RUCK Podiatry Couch MOON item no. 10492XX. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 56: Replacing Cushions

    As shown in the illustrations below, the cushions of the podiatry couch can be replaced individually. á Assembly Disassembly 1. Magnetically fastened 2. Fastened with 2 screws on guide rail (unscrew with Allen key 4) á 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 57: Wireless Foot Control: Battery Change

    The battery compartment is located on the back of the foot control. You will need a small Phillips screwdriver to open and close the battery compartment. Ensure the correct polarity when inserting the batteries. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 58: Warranty

    We reserve the right to make changes to and deviations from the technical design. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 59: Spare Parts

    Do not dismantle gas-pressurised springs yourself. Do not heat the gas-pressurised springs. Do not try to open gas-pressurised springs by force. Leave this kind of work to experts. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 60: Technical Specifications

    IP 20 Duty cycle 10% (= 2 min. ON /18 min. OFF) Noise level < 70 dB(A) Maximum load 250 kg Warranty 2 years 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 61: Electromagnetic Interference Emission

    Air discharge: ±2 kV, the relative air humidity should be at ±4 kV, ±8 kV, ±15 kV least 30%. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 62 Pulse modulation: 217 Hz; 28 V/m 2450 MHz; pulse modulation: 217 Hz; 28 V/m; 5240, 5500, 5785 MHz; Pulse modulation: 217 Hz; 9 V/m 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 63 "d" is the recommended safety distance in meters (m). Power-frequency 30 A/m, 50 Hz magnetic fields (IEC 61000-4-8) 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 64 0% UT for 250/300 cycles vice be powered by an uninter- at 0° ruptible power supply or battery. 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 65 Notes 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 66 Notes 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 67 Notes 8000302 | Instructions for use RUCK Podiatry Couch MOON | REV 05 | Revision status 30/11/2023...
  • Page 68 HELLMUT RUCK GmbH Daimlerstr. 23 75305 Neuenbürg, Germany Tel. +49 (0)7082 944 20 Fax +49 (0)7082 944 22 22 contact@hellmut-ruck.uk hellmut-ruck.uk...

Table of Contents