ebm-papst S4E500AM03LA-001 Operating Instructions Manual
ebm-papst S4E500AM03LA-001 Operating Instructions Manual

ebm-papst S4E500AM03LA-001 Operating Instructions Manual

Advertisement

Quick Links

Part Number
S4E500AM03LA-001
Operating Instructions
ebm-papst A&NZ Pty Ltd
10 Oxford Road
Laverton North VIC 3026
Australia
Phone: +61 3 9360 6400
Fax: +61 3 9360 6464
sales@ebmpapst.com.au
www.ebmpapst.com.au
CONTENTS
1.
1.1
Hazard levels for warning ................................................. 1
1.2
Staff qualification .............................................................. 1
1.3
Basic safety rules ............................................................. 1
1.4
Voltage ............................................................................. 1
1.5
Safety and protective features .......................................... 2
1.6
Mechanical movement ...................................................... 2
1.7
Emission ........................................................................... 2
1.8
Hot surface ....................................................................... 2
1.9
Transport .......................................................................... 2
1.10 Storage ............................................................................. 2
2.
INTENDED USE ............................................................... 3
3.
TECHNICAL DATA .......................................................... 4
3.1
Product drawing ................................................................ 4
3.2
Nominal data .................................................................... 5
3.3
Technical description ........................................................ 5
3.4
Mounting data ................................................................... 5
3.5
Transport and storage conditions ..................................... 5
4.
CONNECTION AND START-UP ..................................... 6
4.1
Mechanical connection ..................................................... 6
4.2
Electrical connection ......................................................... 6
4.2.1
Requirements ..................................................... 6
4.2.2
4.2.3
Voltage control .................................................... 7
4.2.4
Frequency inverter .............................................. 7
4.3
Connection in terminal box ............................................... 7
4.3.1
Preparing cables for connection ......................... 7
4.3.2
Connecting wires to terminals ............................ 7
4.3.3
Cable routing ...................................................... 7
4.3.4
Motor protection .................................................. 8
4.4
Connection diagram ......................................................... 8
4.5
Opening additional cable glands ...................................... 8
4.6
Checking connections ...................................................... 9
4.7
Switch on the device ......................................................... 9
4.8
Switching off the device .................................................... 9
5.
CAUSES AND REMEDIES .............................................. 9
5.1
Cleaning ......................................................................... 10
5.2
Safety inspection ............................................................ 10
5.3
Disposal .......................................................................... 10
5.3.1
5.3.2
Disassembly ..................................................... 10
5.3.3
Component disposal ......................................... 10
Item no. LS-147
ebm-papst A&NZ Pty Ltd
10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464
ABN 33 115 927 556
NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246
sales@ebmpapst.com.au · www.ebmpapst.com.au
1.

SAFETY REGULATIONS AND INFORMATION

Please read these operating instructions carefully before starting
work on the device. Observe the following warnings to prevent
malfunctions or danger to persons.
These operating instructions are to be regarded as part of the
device. The device is only to be sold or passed on together with
the operating instructions.
These operating instructions may be duplicated and distributed
to inform about potential dangers and their prevention.

1.1 Hazard levels for warning

These operating instructions use the following hazard levels to
indicate potentially hazardous situations and important safety
regulations:

1.2 Staff qualification

The device may only be transported, unpacked, installed,
operated, maintained and otherwise used by suitably qualified,
trained and authorised technical staff.
Only authorised specialists are permitted to install the device, to
carry out a test run and to perform work on the electrical
installation.

1.3 Basic safety rules

The safety hazards associated with the device must be
assessed again following installtion in the final product.
Note the following when working on the device:
Do not perform any modifications, additions or conversions
on the device without the approval of ebm-papst A&NZ.

1.4 Voltage

Check the electrical equipment of the device at regular
intervals, see Chapter 5.2 Safety test.
Replace loose connections and defective cables
immediately.
Revision 001
Release 10/04/2017
DANGER
Indicates an imminently hazardous situation which
will result in death or serious injury if the specified
actions are not taken. Compliance with the
instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can
result in death or serious injury if the specified actions
are not taken. Exercise extreme caution while
working.
CAUTION
Indicates a potentially hazardous situation which can
result in minor or moderate injury or damage to
property if the specified actions are not taken.
NOTE
A potentially harmful situation can occur and, if not
avoided, can lead to property damage.
Page 1 of 10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S4E500AM03LA-001 and is the answer not in the manual?

Questions and answers

Summary of Contents for ebm-papst S4E500AM03LA-001

  • Page 1: Table Of Contents

    Switch on the device ............9 Do not perform any modifications, additions or conversions  Switching off the device ............ 9 on the device without the approval of ebm-papst A&NZ. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES ..........9 1.4 Voltage Cleaning .................
  • Page 2: Safety And Protective Features

    Revision 001 Release 10/04/2017 Page 2 of 10 ebm-papst A&NZ Pty Ltd 10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464 ABN 33 115 927 556 NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246...
  • Page 3: Intended Use

    Revision 001 Release 10/04/2017 Page 3 of 10 ebm-papst A&NZ Pty Ltd 10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464 ABN 33 115 927 556 NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246...
  • Page 4: Technical Data

    Revision 001 Release 10/04/2017 Page 4 of 10 ebm-papst A&NZ Pty Ltd 10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464 ABN 33 115 927 556 NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246...
  • Page 5: Nominal Data

    If you have Method of obtaining data maximum running at specific questions, contact ebm-papst A&NZ for load free air support. Valid for approval /  Use the device in accordance with its degree of protection.
  • Page 6: Connection And Start-Up

    NOTE the connection data. Motor capacitor  If the motor run capacitor was not installed by ebm-papst, → The product is equipped with a motor capacitor check whether the information on the motor run capacitor with safety protection class P0/S0 according to matches the information on the nameplate.
  • Page 7: Residual Current Circuit Breaker (Rccb)

    Revision 001 Release 10/04/2017 Page 7 of 10 ebm-papst A&NZ Pty Ltd 10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464 ABN 33 115 927 556 NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246...
  • Page 8: Motor Protection

    Revision 001 Release 10/04/2017 Page 8 of 10 ebm-papst A&NZ Pty Ltd 10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464 ABN 33 115 927 556 NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246...
  • Page 9: Checking Connections

    Do not perform any repairs on your device. Return the device to  Check the cables for proper fit. ebm-papst A&NZ for repair or replacement.  Screw the terminal box cover closed back on again. Terminal box tightening torque, see Chapter 3.1 Product WARNING drawing.
  • Page 10: Cleaning

    ISO 14001 and rigorously Please contact ebm-papst for any other questions on disposal. Item no. LS-147 Revision 001...