Download Print this page

Aiphone AP-M Series Operation Manual page 2

High-power intercom

Advertisement

OPERATIONS on AP-M
Placing a call to sub
1. Depress a station selector button. The channel to a sub
station is established.
2. Depress black CALL button to cad with auido tone.
3. OR Transmit voice depressing TALK button.
Release TALK button to receive.
4. Depress OFF button to return to standby mode.
■ Transmitting Group Call (max. 5 subs)
1. Depress 1 to 5 station selector
buttons.
2. Depress TALK button to
transmit to all.
3. Depress OFF button(s) to pop
up al! station selector buttons.
RECEIVE - VOL - TRANSMIT
Receiving a call from sub
1. Sub calls in with audio tone and an LED, lit for 15 sec.
2. Depress the lit station selector button.
3. Transmit with TALK button held down. Release TALK
button to receive.
4. Depress OFF button to reset.
■ Communication between AP-M's
1. The other AP-M calls in with tone or voice.
2. The responding master simply speaks hands free.
3. When the initiating master is finished, press OFF button.
★ To call AP-M, operate in the same manner as when
calling a sub.
■ Adjustments
1. Adjust each RECEIVE & TRANSMIT volume to either
position HIGH - MID - LOW as needed.
2. Replace to mid position at end of communication.
■ Operations on AP-1M
To call a sub with tone, press both OFF and TALK buttons.
Or press TALK button and call by voice. Proceed
communications with TALK button. Depress OFF button at
end of concersation.
3
TECHNICAL PRECAUTIONS
Power switch
■ Adjustments
■ Cleaning
■ Before asking for repairs
If AP-M is unplugged or its power switch is turned off, it cannot receive sub's call nor
transmit a call to subs. However, it can receive the other AP-M's call-in tone and voice.
Acquire substantially enough TRANSMIT and RECEIVE volume levels, adjust PRESET
controls on back panel, after setting front switches to mid position.
Clean your AP-M equipment with a soft cloth dampened with neutral household cleanser.
Never use any abrasive cleaner or cloth.
If AP-M system becomes inoperative or malfunctions, DO NOT attempt to open or remove
AP-M units. Ask qualified personnel.
4
SPECIFICATIONS
(AP-M)
Power source:
Power consumption:
Communication output:
Dimensions & weight:
110 - 125V AC, 127V AC, 220-240V AC, 50/60Hz. (AP-M). 230V AC, 50/60Hz. (AP-M/A)
Max. 45W. 4W standby (AP-M, AP-M/A).
AP-M to sub
10 watts max. AP-M to AP-M 0.3watts max.
Sub to AP-M
0.3watts max.
Desk use; AP-1M; 240H x 196W x 114D (mm). 9-7/16"H x 7-3/4"W x 4-1/2"D.
AP-5M, 10M: 253H x 276Wx MOD (mm).10"H x 11"W x 5-1/2"D.
AP-1M: 3.2Kg (7.05 lbs.) AP-5M: 4.0Kg (8.82 lbs.) AP-10M: 4.2Kg (9.26 lbs.) approx.
I
WARRANTY
^
Aiphone warrants its products to be free from defects of materia! and workmanship under normal use and service for a period of one
^
year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which
examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision
^
whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of
^
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
batteries or damage caused by batteries used in connection with the product.
^
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
AIPHONE CO., LTD., Nagoya, Japan
AIPHONE CORPORATION, Bellevue, WA, USA
AIPHONE EUROPE NV, Antwerp, Belgium
©
COMMUNICATION SYSTEMS
AIPHONE
HOME. BUSINESS, INDUSTRY.
AP-M-O/M (E)1096A
-
2
-
Printed in Japan (E)

Advertisement

loading

This manual is also suitable for:

Ap-1mAp-5mAp-10m