Cause:
The Circuit Board is poten ally damaged/faulty.
E1,
Drive Error
Remedy:
E4
Try ac va ng the door again. If the fault persists, return the Circuit board for
repair/replacement.
Cause:
The 20A fuse on the Circuit Board has blown.
Remedy:
Fu
Fuse Blown
The fuse may have blown due to excessive forces being applied during the door
opera on. Ensure that the door is moving easily and is balanced and replace the
fuse with a new 20A fuse.
If the fault persists, return the Circuit Board for repair/replacement.
Cause:
The Circuit Board has detected a motor disconnec on.
Motor Disconnect
di
Remedy:
Check that the motor wires are correctly connected to the Circuit Board. If the fault
persists, return the Circuit Board for repair/replacement.
Cause:
Limits not programmed.
No Limits
nL
Remedy:
Program the limits.
DACE warrants that LUX DC12 operators will be free from defects in material and workmanship for a period of 24
months of opera on. Where opera onal data is not available, the warranty claim must be accompanied by the
original invoice. In the event that both opera onal data and the original invoice are not available the warranty will
be deemed to have been in effect from the date of manufacture. This warranty only covers the gearbox and
onboard controller, it excludes any other products that might have been supplied with the operator such as a
transformer, ba ery or beams (warranty informa on regarding products may be found in the installa on guide
pertaining to each product). This warranty explicitly only covers the repair, components and labour carried out at
DACE, all other costs will be for the account of the purchaser.
This warranty does not apply if:
the operator was subjected to misuse,
the operator was installed contrary to the specifica ons provided in this manual,
any a empt has been made to repair the goods by any workshop and/or person not authorised to do so by
DACE or
if goods have been repaired using components not tested, passed or authorised by DACE
This warranty does not cover:
any Acts of God, including lightning, hail, water, power surge, insect damage, corrosion,
the transport, or costs associated with the transport, of the defec ve product to a designated DACE repair
centre,
contractor or other third party costs
any other costs that may have been incurred by the purchaser or any other party or
on site repairs.
This warranty is a factory warranty, all goods will be repaired at the factory or one of the DACE designated repair
centres.
In the case of interna onal customers, the defec ve product must be returned to the supplier from where the
product was purchased WITH PROOF OF PURCHASE FROM THAT SUPPLIER.
HEAD OFFICE: Kwazulu Natal, SOUTH AFRICA
CAUSE & REMEDY
WARRANTY
+27 31 825 7484
info@dace.co.za
www.dace.co.za
Facebook.com/DuraAccessControlEquipment
24
Garage Door Operator
 12 Volt DC
 Vertical Mount Roll Up
 Operates a Single or Double Garage
Door
Ver 1.01

Advertisement

loading

Summary of Contents for DACE LUX DC12

  • Page 1 Door DACE warrants that LUX DC12 operators will be free from defects in material and workmanship for a period of 24 months of opera on. Where opera onal data is not available, the warranty claim must be accompanied by the original invoice.
  • Page 2 Table of Contents Page ERROR MEANING CAUSE & REMEDY CODE Foreword Cause: The infrared beam between the two Safety Beam sensors are blocked, indica ng Disclaimer an obstruc on or the ba eries in the transmi er beam are low. Remedy: Glossary Remove anything that may be obstruc ng the doorway.
  • Page 3 9 minutes) or the light can be Power Input Your owners manual will introduce you to the features and opera on of your new LUX DC12. It is suggested that ac vated via a dedicated remote LIMITS AUX LOCK 12V TRIG INF GND...
  • Page 4 When the force required to open the garage door is equal to the force required to close Balanced Door the garage door. OPERATOR & MAINS STATUS LUX DC12 Control Board The main electronic circuit board housed inside the operator. Control Board...
  • Page 5 For the purposes of the wiring diagram DuraOp cs Wireless Safety Beams (code DOPT03) are shown. Refer to ‘Enable or Disable Safety Beams..Menu 3’ for programming. Board Input Supply 12 - 18V AC or 17 - 22V DC LUX DC12 Motor Voltage Control Board Motor Power (Rated)
  • Page 6 The LUX operator can be ac vated using other external devices such as Push Bu ons, external Receivers or GSM Double Door - (x2) Receivers. Drive Channel LUX DC12 Drive Channel Foot Control Board Channel End Stopper (op onal) Power...
  • Page 7 1) Ensure the ba ery is connected to the Operator. The LUX DC12 Ver cal Mount Roll Up Operator is used to operate either single or double roll up garage doors. If a single door is to be automated, the drive channel will be mounted on either the le or right hand side of the door.
  • Page 8 MOUNTING THE FLOATING BRACKET TO THE WALL PROGRAMMING A REMOTE BUTTON TO TURN THE OPERATOR LIGHT ON and OFF Step 1: Marking & Drilling the Wall (Single door): 1) Ensure the ba ery is connected to the Operator. 1. Draw a ver cal line on the wall, a minimum of 80mm from the most extreme point of the garage door (usually the Door Axle).
  • Page 9 Step 2: Fastening the Floa ng Bracket to the wall (Single & Double Door): .................Output op ons available (con nued): With the operator level, lightly tap the supplied wall plug into the hole drilled in step 1. a) Auxiliary Status (AS): ●...
  • Page 10 Step 4: SETTING AUTO CLOSE ..Menu 4 Close the Garage door/s, ensuring that the door’s rubber seal/s (1) are si ng flat on the floor. 1) Ensure the ba ery is connected to the Operator. 2) Press the SET bu on to enter the Programming Menu (Pr). 3) Press the DOWN bu on un l the Auto Close Menu (AC) is visible.
  • Page 11 BEFORE PROGRAMMING & COMMISSIONING THE OPERATOR ENABLE OR DISABLE SAFETY BEAMS ..Menu 3 The LUX DC12 operator uses the 12V ba ery for normal opera on, it is important that the ba ery is always connected when the operator is in use.
  • Page 12 Programming Remotes: ▶ SETTING THE PHYSICAL OPEN & CLOSE LIMITS The Circuit Board has a built in receiver and the remotes, supplied as part of the operator kit, will have already been programmed to the operator at the factory. To add addi onal remotes (up to 64) refer to ‘Programming Remotes’ on page 16.