Important Safety Instructions Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instruc- tions.
CF23 8ND United Kingdom Equipment Type: Commercial Audio Power Amplifiers Family Name: D Family Model Names: D-45, D-75A EMC Standards: EN 55103-1:1995 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 1: Emissions...
Table of Contents Important Safety Instructions ...2 Declaration of Conformity ...3 1 Welcome ... 5 1.1 Features ...5 1.2 How to Use This Manual ...5 2 Setup ... 6 2.1 Unpack Your Amplifier...6 2.2 Install Your Amplifier ...6 2.3 Ensure Proper Cooling ...6 2.4 Choose Input Wire and Connectors ...7 2.5 Choose Output Wire and Connectors ...7 2.6 Wire Your System ...8...
Reliability is the first thing you get with your purchase of a Crown power amplifier. The D-45 1.1 Features and D-75A both deliver dependable operation Your dual-channel (stereo) amplifier can with a wide variety of loads.
You may also stack amps without using a cabinet. NOTE: When transporting, amplifiers should be supported at the front. Figure 2.1 D-45 and D-75A Dimensions D Series Power Amplifiers 2.3 Ensure Proper Cooling When using an equipment rack, do not mount units directly on top of each other.
D Series Power Amplifiers 2 Setup 2.4 Choose Input Wire and Connectors Figure 2.3 shows connector pin assignments for balanced wiring, and Figure 2.4 shows connec- tor pin assignments for unbalanced wiring. NOTE: Custom wiring should only be per- formed by qualified personnel. 2.5 Choose Output Wire and Connectors Crown recommends using professionally con-...
2 Setup 2.6 Wire Your System 2.6.1 Dual Mode Typical input and output wiring is shown in Figure 2.6. INPUTS: Connect input wiring for each channel. OUTPUTS: Maintain proper polarity (+/-) on output connec- tors. Connect Channel 1 positive (+) speaker load to Channel 1 positive terminal of amp;...
D Series Power Amplifiers 2 Setup 2.7 Connect to AC Mains Connect your amplifier to the AC mains power source (power outlet) with the supplied AC power cordset. WARNING: The third prong of this con- nector (ground) is an important safety feature.
3 Operation 3.1 Precautions Your amplifier is protected from internal and exter- nal faults, but you should still take the following precautions for optimum performance and safety: 1. Before use, your amplifier first must be config- ured for proper operation, including input and output wiring hookup.
3.2 Controls, Indicators and Con- nectors Figure Figure 3.1 shows the controls, indica- tors and connectors on the front panel and back panel of the D-75A. The D-45 layout is similar. Operation Manual WARNING: HEADPHONE JACK SUPPLIES FULL OUTPUT POWER AND MAY DAMAGE HEADPHONES OR CAUSE HEARING DAMAGE.
3 Operation 3.3 Indicators Your amplifier has five front panel indicators. First, a power indicator behind the front panel becomes visible when the unit is turned on and has power. A signal indicator for each channel (Figure 3.2 ) flashes when there is output from the amplifier.
26 dB gain will be ideal. With this default setting, full output power is achieved with an input signal of 0.632 volts for the D-45, and 0.837 volts for the D-75A. Some applications may require the gain struc- ture to be calculated based on a sensitivity of 0.775 volts.
5 Troubleshooting page 14 CONDITION: Power indicator is off. POSSIBLE REASON • The amplifier has lost AC power. • The amplifier’s Power switch is off. • The amplifier is not plugged into the power receptacle. • The amplifier output level is so high that the power supply fuse has blown.
Required AC Mains North American units International units Power Draw at Idle Cooling Dimensions: Width, Height, Depth Net Weight, Shipping Weight Operation Manual D-45 D D-455 ± 0.1 dB +10° to -15° 106 dB unweighted < 0.05% < 0.01% > 400 >100 dB...
Page 16
(See note 1) (See note 2) 20Hz-20kHz 1 kHz 1 kHz 20 Hz 50 Hz Figure 6.1 D-45 Power Matrix D-75A Max. Aver- Single-Cycle Tone Burst FTC Continuous age Power at Watts at < 0.05% THD Average Power at 0.1% THD 0.1% THD...
D Series Power Amplifiers 7 Service Crown amplifiers are quality units that rarely require servicing. Before returning your unit for servicing, please contact Crown Technical Support to verify the need for servicing. This unit has very sophisticated circuitry which should only be serviced by a fully trained techni- cian.
8 Warranty SUMMARY OF WARRANTY Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUB- SEQUENT OWNER of each NEW Crown product, for a period of three (3) years from the date of purchase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and workmanship.
Page 19
D Series Power Amplifiers 8 Warranty SUMMARY OF WARRANTY Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUB- SEQUENT OWNER of each NEW Crown1 product, for a period of three (3) years from the date of pur- chase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and workmanship, and we...
Page 20
D Series Power Amplifiers NOTES page 20 Operation Manual...