electrochemical breathalyser NF EN 16280
11-mm electrochemical sensor
ê Legal limit for driving in European countries
Comply with the applicable legislation in terms of
breath alcohol levels behind the wheel
Limit in mg/L
Zero tolerance
Relationship between the different units used in Europe:
1
- e t h y w a y v2, User's Manual
-
0.40
0.25
0.20
0.10
0.25 mg/L = 25 μg/100 ml
Description
United Kingdom, Ireland,
Luxembourg, Malta
Austria, Belgium,
Bulgaria, Cyprus,
Denmark, Finland, France,
Germany, Greece, Italy,
Latvia, the Netherlands,
Portugal, Slovenia, Spain
Lithuania
Norway, Poland, Sweden
Estonia, Romania,
Slovakia, Czech Republic,
Hungary
GB
USER'S MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ETHYWAY V2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Skyfine ETHYWAY V2

  • Page 1 USER'S MANUAL electrochemical breathalyser NF EN 16280 11-mm electrochemical sensor ê Legal limit for driving in European countries Comply with the applicable legislation in terms of breath alcohol levels behind the wheel Limit in mg/L Description United Kingdom, Ireland, 0.40 Luxembourg, Malta Austria, Belgium, Bulgaria, Cyprus,...
  • Page 2 DISPLAY MODE: (Option chosen at the time of acquisition) Display mode 1: Your ETHYWAY V2 has NF certification for a legal limit of 0.25 mg/L of exhaled air (legal limit in France). Above 0.24 mg/L, your device displays HI and emits a beep.
  • Page 3 ê Power supply Slide the cover off the back of the device — Insert two 1.5-V AAA alkaline batteries, being careful with the — polarity symbols: +/- ê Instructions for use Insert a mouthpiece into the mouthpiece holder — (change the mouthpiece with each use). Using mouthpieces: —...
  • Page 4 Memory mode: — After your test, results displayed seconds. In the meantime, after 7 seconds the device beeps. After this signal, press the test button to display the last 10 results. The memory is displayed starting with the last test performed.
  • Page 5 ê Important information Never use the breathalyser without a disposable mouthpiece. — This could cause permanent damage to the fuel cell and will not be covered by the warranty. Wait at least 20 minutes after consuming the last alcoholic — beverage.
  • Page 6 ê Technical features Sensor: 11-mm electrochemical sensor — Display: LED — Dimensions: 105 x 45 x 17 mm — Power supply: Two 1.5-V AAA alkaline batteries — Operating temperature: +10°C to +40°C — Auto-OFF: 15 seconds — Accuracy: +/- 0.03 mg/L to 0.25 mg/L —...
  • Page 7 ê Environment and safety Do not throw batteries into fire. Alkaline batteries can be recharged. Danger of explosion! Only use the recommended single-use batteries and mouthpieces. All persons in possession of batteries and accumulators are — responsible for managing their disposal. They must ensure they are disposed of in compliance with the applicable regulations.
  • Page 8 ETHYWAYV2 has been approved according to European standard NF EN 16280:2012. Manufacturer: SKYFINE Distributor: OBJECTIF PREVENTION Model: ETHYWAY V2 Breathalyser equipped with an electrochemical cell - e t h y w a y v2, User's Manual...

Table of Contents