Device ID Control byte Function Data length
Value 1
01 = 1 channel
A5 C3 3C 5A
FF
63
07
02
...
08 = 8 channel
Value1 byte: Input channel number.
Value2 byte: Phantom power status.
Example
Command
HEX code
Feedback
Read input
Input 3
3 phantom
A5 C3 3C 5A FF 63 07 01 03 EE
A5 C3 3C 5A FF 63 07 02 03 01 EE
phantom On
power status
Read input
Input 1
1 phantom
A5 C3 3C 5A FF 63 07 01 01 EE
A5 C3 3C 5A FF 63 07 02 01 00 EE
phantom Off
power status
30
USER MANUAL
DSP8X8 Digital Signal Processor
AFC FEEDBACK CONTROL
Data
Value 2
End
Start
Device ID Control byte Function
length
01 = 1 channel
A5 C3 3C 5A
FF
36
08
02
00 =Phantom Off
08 = 8 channel
EE
01 =Phantom On
Value1 byte: Input channel number.
Value2 byte: AFC On/Off control and level.
Example
Command
HEX code
Turn On input 1 AFC on level 2
A5 C3 3C 5A FF 36 08 02 01 02 EE
HEX code
Turn Off input 1 AFC
A5 C3 3C 5A FF 36 08 02 01 00 EE
READ AFC STATUS
Start
Device ID
Control byte
Function
Data length
A5 C3 3C 5A
FF
63
08
Value1 byte: Channel number.
Software interface
Feedback
Value 1
Value 2
End
Start
Device ID Control byte Function Data length
00 = AFC is Off
...
01 = AFC level 1
EE
02 = AFC level 2
A5 C3 3C 5A
FF
Value1 byte: Channel number.
Value 2 byte: AFC level.
Feedback
HEX code
Sending successful
00
Example
Command
HEX code
Sending failed
01
Read input 5
A5 C3 3C 5A FF 63 08 01 05 EE Input 5 AFC level 1
AFC status
Value 1
End
Read input 8
A5 C3 3C 5A FF 63 08 01 08 EE Input 5 AFC level 2
01 = 1 channel
AFC status
01
...
EE
08 = 8 channel
MATRIX CONTROL
Value 1
Value 2
End
Start
01 = 1 channel
00 = AFC is Off
A5 C3 3C 5A
63
08
02
...
01 = AFC level 1
EE
08 = 8 channel
02 = AFC level 2
Value 1 byte: input channel.
Value 2 byte: output channel.
Value 3 byte: input and output status, connected or not.
Example
Feedback
HEX code
A5 C3 3C 5A FF 63 08 02 05 01 EE
Input 1 connected to output 3
Input 1 disconnected from output 1 A5 C3 3C 5A FF 36 09 03 01 01 00 EE
A5 C3 3C 5A FF 63 08 02 08 02 EE
Input 2 connected to output 1
Control
Data
Device ID
Function
Value 1
Value 2
Value 3
End
byte
length
01
01
01
= 1 input
= 1 output
= connect
FF
36
09
03
...
...
EE
08
08
00
= 8 input
= 8 output
= disconnect
Command
HEX code
Feedback
HEX code
A5 C3 3C 5A FF 36 09 03 01 03 01 EE
Sending successful
00
Sending failed
01
A5 C3 3C 5A FF 36 09 03 02 01 01 EE
USER MANUAL DSP8X8 Digital Signal Processor