Specifications - Mitsubishi Electric MSZ-LN18VGW Operating Instructions Manual

Indoor unit
Hide thumbs Also See for MSZ-LN18VGW:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
● OPERATING INSTRUCTIONS ●
W
i-Fi INTERFACE SETTING UP
Wi-Fi interface
S
PECIFICATIONS
EN
Set name
Model
Indoor
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant fi lling capacity (R32)
Indoor
IP code
Outdoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor
(Super High/
High/Med./
Noise level
Low./Silent)
Outdoor
Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
Wi-Fi interface
Model
Input Voltage
Power consumption
Size H×W×D (mm)
Weight (g)
Transmitter power level (MAX.)
RF channel
Radio protocol
Encryption
Authentication
Software Ver
For Declaration of Conformity, please go to the website below.
http://www.melcloud.com/Support
EN-6
Wi-Fi interface
-
MSZ-LN18VG
-
Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating
kW
-
-
kW
-
-
kg
kg
-
kg
-
-
MPa
-
MPa
42/36/29/
45/36/29/
dB(A)
23/19
24/19
dB(A)
-
-
Outdoor
Indoor
MUZ-LN25/35/50/60VG MUZ-LN25/35/50VGHZ
32°C DB
46°C DB
23°C WB
21°C DB
-10°C DB
15°C WB
27°C DB
24°C DB
18°C WB
20°C DB
-15°C DB
-16°C WB
MAC-567IFB-E
DC12.7 V (from indoor unit)
MAX. 2 W
79×44×18.5
60 (including cable)
17.5 dBm @IEEE 802.11b
1ch ~ 13ch (2412~2472 MHz)
IEEE 802.11b/g/n (20)
AES
WPA2-PSK
XX.00
This Wi-Fi interface, communicates the status information and controls
the commands from the MELCloud by connecting to the indoor unit.
Note:
• Set up a connection between the Wi-Fi interface and the Router. Refer to the
SETUP MANUAL and SETUP QUICK REFERENCE GUIDE provided with
the unit.
• For SETUP MANUAL, please go to the website below.
http://www.melcloud.com/Support
• For MELCloud User Manual, please go to the website below.
http://www.melcloud.com/Support
MSZ-LN25VG(HZ) MSZ-LN35VG(HZ)
MSZ-LN25VG
MSZ-LN35VG
MUZ-LN25VG(HZ) MUZ-LN35VG(HZ)
~ /N, 230 V, 50 Hz
2.5
3.2
3.5
4.0
0.485
0.580
0.820
0.800
25(HZ)/35:35 / 35HZ:36
1.00
42/36/29/
45/36/29/
43/36/29/
45/36/29/
23/19
24/19
24/19
24/19
46
49
49
50
46°C DB
-10°C DB
24°C DB
18°C WB
-25°C DB
-26°C WB
DB: Dry Bulb
WB: Wet Bulb
W
HEN YOU THINK THAT
TROUBLE HAS OCCURRED
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/
OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An ampli-
fi er may be required for the affected device.
• When an abnormal sound is heard.
• When any refrigerant leakage is found.
MSZ-LN50VG(HZ)
MSZ-LN50VG
MUZ-LN50VG
MUZ-LN50VGHZ
5.0
6.0
5.0
1.380
1.480
1.380
1.480
15.5
40
55
1.25
IP 20
IP 24
2.77
4.17
46/39/35/
47/39/34/
46/39/35/
47/39/34/
31/27
29/25
31/27
29/25
51
54
51
Note:
1. Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Heating — Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
2. LN18 have no specifi cations for single combination. These
indoor models are only for multi system air conditioner.
As for the specifi cations of multi system, please confi rm
your dealer and/or refer to the catalogue.
MSZ-LN60VG
MSZ-LN60VG
MUZ-LN60VG
6.0
6.1
6.8
1.790
1.810
55
1.45
49/45/41/
49/45/41/
37/29
37/29
54
55
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents