This instruction manual is designed to use the product safely with keeping its best
performance.
Be sure to read "Safety precautions" before use.
IMPORTANT
Please keep this manual in a place easily accessible to every users.
Model MP-2100
Model MP-2101
Model MP-2110
Model MP-2111
Model MP-2010A
Model MP-2010B
Tokyo Rikakikai Co., Ltd.
Instruction Manual
R02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MP-2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EYELA MP-2000

  • Page 1 Peristaltic tube Instruction Manual pump Model MP-2100 Model MP-2000 Model MP-2101 Model MP-2001 Model MP-2110 Model MP-2010 Model MP-2111 Model MP-2011 Model MP-2000A Model MP-2010A Model MP-2000B Model MP-2010B This instruction manual is designed to use the product safely with keeping its best performance.
  • Page 2 Important Safety Notices 1. Signal words Using flammable or combustible solution with this To ensure the safety, this manual defines the product might cause a personal injury or an information on such matters as requiring accident when the product is handled improperly. particular care in the safety as follows in terms Due to its function and features, operation at a of the importance and risk and attaches the...
  • Page 3 * If damaged and illegible, be sure to change the warning label to the new one. Send the request for the new label to us. ●Peristaltic tube pump (Model MP-2000) Warning Danger of a fire Take extreme care...
  • Page 4: Table Of Contents

    4 - 3 Connecting the utilities Details of packaged items Be sure to check the type and quantity of parts before attempting to set them. Product MP-2000 MP-2001 MP-2010 MP-2011 MP-2000A MP-2000B MP-2010A MP-2010B MP-2100 MP-2101 MP-2110 MP-2111 No.1 ○ ○...
  • Page 5 ■Package box No.3 Tube case set TCS-0(Screw-adjustable) Fixing bolt ■Package box No.4 Tube case set (For 1 stage) TCS-1(Spring type) Contents Tube case cover (For 1 Tube case (For upper stage) upper stage) 2 Tube case cover (For upper stage) 3 Fixing bolt (For 1 stage) 4 Roller set Tube case...
  • Page 6: For Safe Operation

    For safe operation Be sure to handle the product properly and implement leak preventive measures based on the characteristics of the specific liquid to be sent. Take extreme care when using flammable or combustible solution. Warning Flammable or combustible solution (methanol, etc) will, when it is left at a room temperature or higher temperature (or lower temperature for some solutions) , ignite from some ignition source and combust.
  • Page 7: Product Overview

    20℃, back pressure of 0, a silicon tube(s) is used. ※ Performance is not warranted for any other commercially available tubes other then specified by EYELA. ※ Flow, flow precision, discharge pressure and other pressures will differ depending on the tube used.
  • Page 8 Product name Constant volume fluid supply pump(Peristaltic tube pump) Model MP-2000A MP-2010A MP-2000B MP-2010B Tube holding system Groove with a fixed width Flow range 10~180 mL/h 0.5~9.0 mL/h 80~1450 mL/h 5.0~72.5 mL/h ± 2% (Repetition precision: within ± 1%) Flow precision Max.
  • Page 9: Discharge Flow Characteristics

    2-3 Discharge flow characteristics (Not warranted for any other tubes other than specified by EYELA) Discharge flow range[mL/h] Model (flow route) Tube(I.D. x O.D.)[mm] MP-2000,2100 series MP-2010 series MP-2000 (× 2) 1.15× 3.2 10~180 0.5~9 MP-2100 (× 4) MP-2001 (× 2) 2.15×...
  • Page 10: Names Of Parts

    2-4 Names of parts MP-2000 MP-2001 MP-2010 MP-2011 Fixing bolt Case cover Tube case set Roller set Tube case Main unit Pilot lamp Power plug Switch Flow adjusting knob Flow characteristics sheet holder MP-2000A MP-2010A MP-2000B MP-2010B Fixing bolt Sheet...
  • Page 11 MP-2100 MP-2101 MP-2110 MP-2111 Fixing bolt for 2 stages (× 2) ※1 Case cover (For upper stage) Tube case set Tube case Roller set (For lower stage) (For upper Tube case stage) Joint shaft ※1 Fixing bolt(× 2) for 1 Case cover stage ※2...
  • Page 12 Control assembly (Common for all models) Pilot lamp Switch Flow adjusting knob Name Description of functions Pilot lamp Turning the switch ON will light the lamp. Switch The switch for tuning power ON/OFF and changing the fluid supply direction. Pushing the switch upward makes the roller turn clockwise and downward, anticlockwise and supply of solution will start.
  • Page 13: Safety Function

    Safety function This product has the safety functions shown below. When any malfunctions occur, take appropriate actions by referring to “P20 Causes and solutions of troubles”. Safety function Safety device Actions Causes Solutions Over current has It will be blown to shut off Contact your dealer or the nearest Fuse flown through the...
  • Page 14: Connecting The Utilities

    *Do not use a branching socket or a tap for connecting to the power supply. Power cord specification (Common for all models) Cable Product Section area of the Thickness model cord (AWG) Length (O.D.) MP-2000 Approx.2. Approx.7.4 0.75mm (AWG18) MP-2010 etc. - 9 -...
  • Page 15: Preparing For Operation

    Touching the rotating roller directly Use of other tubes may prevent specified may cause pinching of your finger or other performance from exercising or cause a personal injuries. malfunction. MP-2000 MP-2010 Tube case MP-2001 MP-2011 1.Tube case set (1) Check the direction of the main unit and the tube case.
  • Page 16 2.Setting the roller set to the tube case ※At the factory shipping, the roller set has been set in Tube case the tube head, which shall be set according to the procedures in “P10 1.Setting the tube case”. * If the roller set has been detached from the tube case, follow the procedures below to set the roller Main unit set to the tube case.
  • Page 17 3.Setting the tube Caution Tube clamp Tightening adjusting bolt Take care for a leak. Be sure to set the tube properly as instructed to avoid leak. Roller (1) Loosen the tightening adjusting bolt and pull out the tube clamp A fully to widen the gap between clamp and Tube clampA...
  • Page 18 (3) Insert the tube into the groove as shown in the right figure. When the tube clamp is unlocked, it will return Lock release with a spring and the tube will be secured. * Tube clamp holds the tube with a spring. Take extreme care when setting the tube so that your finger will not be pinched.
  • Page 19 Tightening adjusting bolt will continuously crush the tube portion between the tube clamp A and the roller causing discharge to occur at the tube. <For models MP-2000 and 2010> Tighten the tightening adjusting bolt by another about ¼ turn from the point above.
  • Page 20 3. Adjusting tightening of the tube (1) Adjust the tightening amount of the tube following the procedures of 6 of the model MP-2000 (2) When you have set the tube on the upper stage, fix it with fixing bolts for 2 stages.
  • Page 21 (Refer to “*Reference" below.) (2) First make sure that the switch on is OFF, insert the power plug into the outlet. ※Reference (Use this to determine the correct length of tubes.) ・MP-2000,2010 (130mm) ・MP-2000A,2010A(120mm) ・MP-2000B,2010B(125mm) - 16 -...
  • Page 22 (3) Place the case cover and lightly press it down with Fixing bolt hand, turn the switch to ON (up or down) and then turn the flow adjusting knob. (Scale:2~3) The tube will sit between the roller and the tube case. Sheet Case cover Tube case...
  • Page 23: Operating Procedures

    5-2 Operating procedures Caution Caution Immediately stop operation if you Regularly replace the tube. notice an abnormality. The tube of the tube pump will be subjected to If you notice an abnormality, immediately repeated compression force with the roller. turn the switch OFF and refer to the section “P20 Thus operating for a long time may wear and Causes and solutions of troubles”.
  • Page 24: Discharge/Suction Direction

    5-3 Discharge/Suction Direction The figure below shows the directions of discharge and suction when the switch is ON to the upper side. The directions will be reversed when the switch is ON to the lower side. MP-2000 MP-2001 MP-2010 MP-2011...
  • Page 25: Troubleshooting And Countermeasures

    Contact your dealer or the nearest service Troubleshooting and countermeasures center for troubles not listed here. Symptom Cause Countermeasures The power plug is removed off the outlet First turn the power switch OFF and then or the inlet. insert the power plug into the outlet or Or it is not securely inserted.
  • Page 26: Maintenance And Inspection

    Maintenance and inspection 7-1 Cleaning and care of the product Caution Warning Remove dust on the outlet Never disassemble the unit. frequently. Operating the unit for a long time with connected Voltage is supplied to some components inside to the outlet may cause dust to accumulate in the the unit and disassembly may cause an electric gap between the outlet and the power plug and shock or other personal injuries.
  • Page 27: Disposal Of Products

    Disposal of product or part must be done according to the specified disposal method. Major component and disposal method Weight External dimensions How to discard Component Model (including protrusions) MP-2000 Approx. 3.0kg MP-2001 127W× 130D× 177H (166W× 152D× 190H) MP-2010 Approx.
  • Page 28: After-Sale Services

    After-sale Services 1. In case the product does not function satisfactorily, 3. Repair during the guarantee period will be made check first referring page according to the guarantee stipulations. troubleshooting to see if this is actually a trouble. 2. If the product remains unsatisfactory even after 4.
  • Page 29: List Of Consumable & Replacement Parts/Parts

    List of consumable & replacement parts/parts ■Tube types Tube size Length Code No. Name Outer appearance (I.D. x O.D.) 125320 φ1.15× φ3.2 125330 125340 φ2.15× φ4.2 125350 PharMed® tube 125360 φ3.15× φ5.2 125370 125380 φ3.70× φ6.1 125390 125460 φ1.15× φ3.2 125470 125480 φ2.15×...
  • Page 30 ■Tube case related items Code No. Item name ③ 251220 Tube case set for MP-2000~4000 TCS-0 ④ 251230 Tube case set for lower stage for MP-2000~4000 TCS-100 ⑤ 251240 Tube case set for MP-2000A~4000A ⑥ 251250 Tube case set for MP-2000B~4000B ⑦...
  • Page 31 Tokyo Rikakikai Co., Ltd. Contact for inquiry EYELA Customer Center Operating time:9:00~12:00 and 13:00~17:00 0120-076-554 URL : http://www.eyela.co.jp FAX : 03-3868-6501...