015157en Operating Instruction Booklet - Translation of the original instructions - Pneumatic Drilling Machine PV16BN 6060836A NOTICE ALL DOCUMENTATIONS ! Before beginning work this operating instruction booklet has to be read through carefully. Always follow the instructions during operation. Give this operating instruction booklet to the operator.
DEPRAG Contents 1 IMPORTANT NOTES ..................... 4 2 SAFETY INSTRUCTIONS ....................5 2.1 General safety instructions for standard operation (outside Ex-area) ......5 2.2 Safety Instructions for Air Drills ..................6 2.3 Additional Safety Instructions for Usage in Ex-area ............. 7 2.4 Owner Obligation ......................
Page 3
14 EU-DECLARATION OF CONFORMITY ..............28 15 EC-DECLARATION OF CONFORMITY ..............29 16 SERVICE LOCATIONS AND AUTHORIZED PARTNERS ........30 List of illustrations Illustration 1 – Diagram of the drill PV16BN ............... 14 Illustration 2 – Areas with the highest measuring temperature .......... 17...
DEPRAG Important Notes The safety and warning instructions contained should invariably be followed! The signal words and symbols used in the technical documentation (safety instructions, operating instruction booklet, etc.) have the following meaning: DANGER Indicates an immediate danger which causes serious injuries or even death if not avoided.
There are moving parts and maybe hot surfaces, during and after operating this air-tool. Assembly / installation, connection, operation as well as maintenance and repair work may only be performed by DEPRAG or qualified persons / technical experts. Injury and damage to property may occur due to inaccurate installation and operation or non-designated use.
DEPRAG 2.2 Safety Instructions for Air Drills See also safety instruction booklet no. 016000 (pink-colored). WARNING Serious injuries or even death possible! Disconnect machine from air/power supply before changing or mounting the inserted tool or accessory. WARNING Breakage of the inserted tool can cause serious injuries.
Assembly / installation, connection, operation as well as maintenance and repair work may only be performed by DEPRAG or qualified persons /technical experts and if the following items are observed:...
2.6 Warranty and Liability Unless otherwise specified, our „General Sales and Delivery Conditions“ apply www.deprag.cz. Warranty and liability claims in regards to persons or equipment damage are invalid if one or several of the following causes apply: • Use of the equipment in a non-designated application.
Depth stop 6072204 4.1 Model number description, tag description Type key (example) Type plate – engraved (example) Manufacturer DEPRAG P V 1 6 B N Type PV16BN Mfg. Year/ 19/…… Serial No. Operating Ex-protection-characteristic max. 6,3 bar Pressure Size information...
DEPRAG 4.2 Nomenclature I M2 Ex h I Mb X Example: II 2G Ex h IIB T6 Gb X Communauté Européenne = European Community This symbol documents the declaration of the manufacturer that the required guidelines – as stated in the Declaration of Conformity – are observed and its provisions are followed.
– this may cause material damage! To avoid a swelling of the seal rings and damage to internal parts of the drill, use only solvents approved by DEPRAG (such as HAKU 1025-810-1 cold cleaner). Seal material: NBR / FKM 5.3 Operating Pressure and Temperature Range...
DEPRAG 5.4 Usage in an Ex- area Always follow the safety instructions while usage the air-drill in an EX-area! The air drill must be grounded, for example by using Grounding • an air-supply line made of metal or • an electrically conductive hose.
DEPRAG 5.5 Pneumatic Installation This pneumatic machine may be operated with lubricated air. The best performance is achieved by adding 1 - 2 drops oil per 1 m of air consumption. Before connecting the air supply line to the drill, clean the air pipe Prior to and the air hose by slightly blowing air into the pipe/hose.
DEPRAG Maintenance unit On-valve Drill PV16BN Silencer Illustration 1 – Diagram of the drill PV16BN 5.6 Air Quality With regard to air quality according to ISO 8573-1:2010 we recommend: Residual Class Residual Dust Residual Water max. max. pressure particle content...
After approximately 1.5 hours of operation, measure and record the surface temperature. The max. permissible temperature of the surface may not be exceeded. When the measured temperature of the surface T exceeded, then the gear must be stopped immediately and you must contact DEPRAG!
40°C for group II category 2G, IIB Gb • 110°C for group I M2, I Mb Ambient temperature in the Ex-area: -20°C to +40°C. If the surface temperature exceeds this mandate. The drill must be stopped immediately and you will need to contact DEPRAG right away .
DEPRAG Handling Use the machine only while observing all safety and maintenance instructions. The drill starts by trigger. 7.1 Optional equipment Name Part No. Press bolt 6071900 Drill chuck MK1 830726 Drill chuck MK2 830727 More equipment such as pressure hoses and connection components etc catalog D3340 or request.
DEPRAG Maintenance and Upkeep The first maintenance should be performed after 500 operating hours. Thereafter, we recommend adjusting the maintenance intervals in accordance with the general usage- and wear conditions of the drill, as well as the condition of the fabrication area.
Principally, use only DEPRAG original spare parts. Otherwise, a reduction of equipment power- output and an increased maintenance requirement occurs. If NON-DEPRAG parts are installed, then DEPRAG is justified to avoid any existing warranty and liability obligations. Only use original DEPRAG service tools in order to avoid causing...
DEPRAG 10 Troubleshooting Fault Cause Corrective Action Drill oper- Torque Speed Drill does ated, but too low too low not run gets slower during op- eration Dirt or other debris in the Check and clean • • • drill Rusty internal Check and clean or •...
DEPRAG 11 Shut Down and Storage • Turn the air supply to “OFF“. • Disconnect the Drill from the air supply. • Blow clean, dry air at low pressure into the air-inlet of the drill. • Drip a couple of drops of oil into the air-inlet channel and turn the shaft by hand so that the oil is evenly distributed.
DEPRAG 13 Technical Data Type PV16BN Order No. 6060836A I M2 Ex h I Mb X Certified according to ATEX II 2G Ex h IIB T6 Gb X right rotation Direction of Rotation Trigger Starting Speed (no load) (rpm) Speed, at max. load (rpm) 0.5 / 0.67...
2016-04 ISO 80079-37 2016-04 DEPRAG CZ a. s., T. G. Masaryka 113, 507 81 Lázně Bělohrad has filed the required documents – under Directive ATEX 2014/34/EU Annex III - with the following authority: FTZÚ, Pikardská 1337/7, Ostrava – Radvanice EU reference number 1026 Archive number: A538 - 17 Lázně...
2006/42/EC. As manufacturer of the machine we declare that the Directives and Standards listed below apply to the following specified machine. Manufacturer and authorized Person for Documentation: DEPRAG CZ a.s. T.G. Masaryka 113 CZ-50781 Lázně Bělohrad PNEUMATIC DRILLING MACHINE Name ...
DEPRAG 16 Service Locations and Authorized Partners Contacts in Czech Republic / Germany as well as contacts worldwide can be found on our web site www.deprag.cz...