IMPORTANT - READ FIRST - IMPORTANT
YOUR SAFETY AND THE SAFETY OF OTHERS ARE VERY IMPORTANT.
WE HAVE PROVIDED MANY IMPORTANT SAFETY MESSAGES IN THIS MANUAL AND ON YOUR
APPLIANCE. ALWAYS READ AND OBEY ALL SAFETY MESSAGES.
OUR PRODUCT INSTRUCTIONS WILL BE UPLOADED ON OUR COMPANY OFFICIAL WEBSITE.
THIS IS THE SAFETY ALERT SYMBOL. THIS SYMBOL ALERTS YOU TO POTENTIAL
HAZARDS THAT CAN KILL OR INJURE YOU AND OTHERS. ALL SAFETY MESSAGES
WILL FOLLOW THE SAFETY ALERT SYMBOL AND EITHER THE WORDS" DANGER",
"WARNING" OR "CAUTION".
DANGER MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT
IN SEVERE PERSONAL INJURY OR DEATH.
WARNING MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY
RESULT IN EXTENSIVE PRODUCT DAMAGE, SERIOUS PERSONAL INJURY, OR
DEATH.
CAUTION MEANS THAT FAILURE TO HEED THIS SAFETY STATEMENT MAY RESULT
IN MINOR OR MODERATE PERSONAL INJURY, OR PROPERTY OR EQUIPMENT
DAMAGE.
ALL SAFETY MESSAGES WILL ALERT YOU TO WHAT THE POTENTIAL HAZARD IS, TELL YOU
HOW TO REDUCE THE CHANCE OF INJURY, AND LET YOU KNOW WHAT CAN HAPPEN IF THE
INSTRUCTIONS ARE NOT FOLLOWED.
=FOLLOW BASIC PRECAUTIONS, INCLUDING THE FOLLOWING:
DANGER:
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING
CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES,
OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A
PERSON RESPONSIBLE FOR THEIR SAFETY.
DANGER:
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH
THE APPLIANCE.
DANGER:
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE
AND PERSONS WITH REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES
OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE
WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN SHALL NOT PLAY
WITH THE APPLIANCE. CLEANING AND USER MAINTENANCE SHALL NOT BE
MADE BY CHILDREN WITHOUT SUPERVISION.
DANGER:
KEEP THE APPLIANCE AND ITS CORD OUT OF REACH OF CHILDREN LESS THAN 8
YEARS.
RECEIVING & INSPECTING THE EQUIPMENT
Even though most equipment is shipped crated, care should be taken during
unloading so the equipment is not damaged while being moved into the building.
1. Visually inspect the exterior of the package and skid or container. Any
damage should be noted and reported to the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon opening, there is
concealed damage to the equipment, notify the carrier. Notification should
be made verbally as well as in written form.
4. Request an inspection by the shipping company of the damaged equipment.
This should be done within 10 days from receipt of the equipment.
5. Be certain to check the compressor compartment housing and visually
inspect the refrigeration package. Be sure lines are secure and base is still
intact.
6. Freight carriers can supply the necessary damage forms upon request.
7. Retain all crating material until an inspection has been made or waived.

INSTALLATION

NOTE:
UNIT REPAIRS WILL NOT BE SUBJECT TO STANDARD UNIT WARRANTIES IF
DUE TO IMPROPER INSTALLATION PROCEDURES.
DANGER:
THE UNIT MUST BE TURNED OFF AND DISCONNECTED FROM THE POWER
SOURCE WHENEVER PERFORMING SERVICE, MAINTENANCE FUNCTIONS OR
CLEANING THE REFRIGERATED AREA.
2
REACH-INS REFRIGERATORS/FREEZERS
DANGER:
RISK OF CHILD ENTRAPMENT. BEFORE YOU THROW AWAY YOUR OLD REFRIGERATOR
OR FREEZER: TAKE OFF THE DOORS LEAVE THE SHELVES IN PLACE SO THAT
CHILDREN MAY NOT EASILY CLIMB INSIDE.
DANGER:
DO NOT STORE EXPLOSIVE SUBSTANCES SUCH AS AEROSOL CANS WITH A
FLAMMABLE PROPELLANT IN THIS APPLIANCE.
DANGER:
THE APPLIANCE USE FLAMMABLE INSULATION BLOWING GAS C5H10, DISPOSAL
OF THE APPLIANCE SHALL IN ACCORDANCE WITH THE REGULATIONS OF LOCAL
AUTHORITIES.
DANGER:
THE KEY FOR APPLIANCE ELECTRIC BOX SHOULD BE SAFE KEPT BY QUALIFIED
PERSONS IN ORDER TO AVOID A HAZARD.
DANGER:
IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER,
ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSONS IN ORDER TO AVOID A
HAZARD.
WARNING: KEEP VENTILATION OPENINGS, IN THE APPLIANCE ENCLOSURE OR IN THE BUILT-IN
STRUCTURE, CLEAR OF OBSTRUCTION.
WARNING: DO NOT USE MECHANICAL DEVICES OR OTHER MEANS TO ACCELERATE
THE DEFROSTING PROCESS, OTHER THAN THOSE RECOMMENDED BY THE
MANUFACTURER.
WARNING: DO NOT DAMAGE THE REFRIGERANT CIRCUIT.
WARNING: DO NOT USE ELECTRICAL APPLIANCES INSIDE THE FOOD STORAGE COMPARTMENTS
OF THE APPLIANCE, UNLESS THEY ARE OF THE TYPE RECOMMENDED BY THE
MANUFACTURER.
WARNING: HANDLING, MOVING, AND USE OF THE REFRIGERATOR OR FREEZER TO AVOID
EITHER DAMAGING THE REFRIGERANT TUBING, OR INCREASING THE RISK OF A
LEAK.
CAUTION:
RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. FOLLOW
HANDLING INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH U.S. GOVERNMENT
REGULATIONS.
CAUTION:
COMPONENT PARTS SHALL BE REPLACED WITH LIKE COMPONENTS AND THAT
SERVICING SHALL BE DONE BY FACTORY AUTHORIZED SERVICE PERSONNEL, SO
AS TO MINIMIZE THE RISK OF POSSIBLE IGNITION DUE TO INCORRECT PARTS OR
IMPROPER SERVICE.
CAUTION:
RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW
HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED.
LOCATION: Units represented in this manual are intended for indoor use only. Be
sure the location chosen has a floor strong enough to support the total weight of
the cabinet and contents. A fully loaded unit can weigh as much as 1500 pounds.
Reinforce the floor as necessary to provide for maximum loading. For the most
efficient refrigeration, be sure to provide good air circulation inside and out
INSIDE CABINET: Do not pack the units so full that air cannot circulate. The
refrigerated air is discharged at the top rear of the unit. It is important to allow
for proper air flow from the top rear to the bottom of the unit. Obstructions to
this air flow can cause evaporator coil freeze ups and loss of temperature or
overflow of water from the evaporator drain pan. The shelves have a rear turn up
on them to prevent this. However, bags and other items can still be located to the
far rear of the cabinet. Air is brought into the evaporator coil with fans mounted
to the front of the coil.
OUTSIDE CABINET: Be sure that the unit has access to ample air. Avoid hot
corners and locations near stoves and ovens. It is recommended that the unit be
installed no closer than 2" from any wall with at least 12" of clear space above
the unit.
LEVELING: A level cabinet looks better and will perform better because the
doors will line up with the frames properly. Use a level to make sure the unit
is level from front to back and side to side. Units supplied with legs will have
adjustable bullet feet to make the necessary adjustments. If the unit is supplied
with casters, no adjustments are available. Ensure the floor where the unit is to
be located is level.
STABILIING: All models are supplied with casters for your convenience. It is very
important, however, that the cabinet be installed in a stable condition with the
front wheels locked while in use. Should it become necessary to lay the unit on
its side or back for any reason, allow at least 24 hours before start-up to allow