Racelogic VBOX NTRIP Quick Start Manual page 3

Hide thumbs Also See for VBOX NTRIP:

Advertisement

8. Press the Save and restart button.
Note: Settings are retained after power cycles.
9. When it has connected to the network provider, the
unit will briefly display a Connected (mobile data
supplier) message.
The NTRIP modem will reboot and attempt to
connect to the internal modem you have
configured. The settings page will be updated with
the new settings and provide a connection status
indication.
10. Press the Change settings button next to the
NTRIP Caster heading to configure the NTRIP
correction service details.
11. Enter the Server Name/IP Address, Port, Mount
Point (correction data stream), Username and
Password information (if required).
Note: These details will be provided by your NTRIP
service provider.
12. Press the Save button.
If there is a problem with the server details, the
unit will briefly display an Invalid Caster
Credentials message.
When it has connected to the NTRIP server, the
unit will briefly display the RTCM Streaming
message.
The settings page will be updated with the new
settings and a connection status indication
along with the number of data bytes received from
the NTRIP server. The front display will also
provide this information.
13. Check that the DIFF LED on the VBOX is solid
green, indicating that it is receiving DGPS
corrections.
Note: If you configure it to use both the internal GSM modem and an external Wi-Fi hotspot, it will attempt to auto-
https://en.racelogic.support//ADAS_Testing/ADAS_Hardware/Peripherals/Telemetry_Systems/NTRIP_Modem
The modem will reboot and connect. When it is
connected, the unit will briefly display "Wi-Fi
Connected".
If it cannot connect to the configured Wi-Fi hotspot
on power up, it will automatically restart
and become a configuration access point.
9. Press the Change settings button next to the
NTRIP Caster heading to configure the NTRIP
correction service details.
10. Enter the Server Name/IP Address, Port, Mount
Point (correction data stream), Username and
Password information (if required).
Note: These details will be provided by your NTRIP
service provider.
11. Press the Save button.
If there is a problem with the server details, the
unit will briefly display an Invalid Caster
Credentials message.
When it has connected to the NTRIP server, the
unit will briefly display the RTCM Streaming
message.
The settings page will be updated with the new
settings and a connection status indication
along with the number of data bytes received from
the NTRIP server. The front display will also
provide this information.
12. Check that the DIFF LED on the VBOX is solid
green, indicating that it is receiving DGPS
corrections.
3