Yamorc YD6016LN Quick Start Manual

Gound sensor 16−fold feedback module

Advertisement

Quick Links

YD6016LN Gound Sensor
16−fold feedback module
Quick star
(2023−05−24)
Designed by Karst Drenth
Made in Germany
Assembled in NL

Advertisement

Table of Contents
loading

Summary of Contents for Yamorc YD6016LN

  • Page 1 YD6016LN Gound Sensor 16−fold feedback module Quick star (2023−05−24) Designed by Karst Drenth Made in Germany Assembled in NL...
  • Page 2: Table Of Contents

    Product/Hardware overview ..…………………………………………………………. 6 Connec on example of the feedback devices for bu3ons, switches, reed contacts, etc………..…………………………………………………………………… 7 Connec on example extension of the YD6016LN via "ES-Link" and "s88N"………………………………………………………………………………………… 8 Configuring the feedback addresses and the total number of the feedback devices………………………………………………………. 9 Use the YD61016LN-GND to configure the switching decoder of...
  • Page 3: Beschreibung

    Via the "ES-IN Link" connec on, it is possible to expand the YD61016LN-GND by another five YD6016ES modules. This creates a single LocoNet® modu-  le with 96 detectors. A3en on! Simultaneous use of "s88N-IN" and "ES-IN Link" is not permi3ed. The "ES-IN Link" connector allows to configure all other modules equipped with an "ES-PGM Link" connector.  www.yamorc.de...
  • Page 4: Moun Ng, Dimensional Drawing

    84 mm x 88 mm x 22 mm Housing Dimensions 42,5 mm 88 mm 94,5 mm, 42,5 mm Distance Between Holes Moun ng The YD61016LN-GND is mounted via the four moun ng holes on the side of the housing. www.yamorc.de...
  • Page 5: Important Notes (Including Health & Safety)

    USB or LocoNet®. The USB isolator prevents dangerous ground loops or equalizing voltages or currents between the components. A common earth connec on of different voltage sources or circuits is not permi3ed. This will destroy the YD6016LN-xx. ...
  • Page 6: Must Read Before Using Y6016Ln Product/Hardware Overview

    At this connec on another five "s88N" standard Feedback modules with 16 inputs can be connected. A0en on! If the "s88N-IN" is used to connect feedback modules, the "ES-IN Link" must not be used at the same me. USB Anschluss LocoNet® Connec on 1 www.yamorc.de...
  • Page 7: Connec On Example Of The Feedback Devices For Bu3Ons, Switches, Reed Contacts, Etc

    Next LocoNet® Components Fleischmann® Switch Bu3on Reed contact Control panel (NOC) (NO) A0en on! All connec on work on the YD61016LN-GND must always be carried out in a de-energised state. Disconnect the power supply from the mains and switched off! www.yamorc.de...
  • Page 8: Connec On Example Extension Of The Yd6016Ln Via "Es-Link" And "S88N

    Attention! Joint use of "ES-OUT Link" and "s88N-OUT" or "ES-IN Link" and "s88N-IN" on the same module is not permitted. A0en on! All connec on work on the YD61016LN-GND must always be carried out in a de-energised state. Disconnect the power supply from the mains and switched off! www.yamorc.de...
  • Page 9: Configuring The Feedback Addresses And The Total

    Configuring the feedback addresses and the total number of feedback devices of the YD61016LN-GND YaMoRC has chosen to make the programming of the YD61016LN-GND as simple as possible. The YD61016LN-GND is preset "out of the box" with the Loco- Net® feedback addresses 1-16. Of course, any other feedback address can also be assigned as the start feedback address. The The start feedback address is assigned by switching the corresponding DCC turnout address via the turnout control panel of the command sta on used.
  • Page 10 The assignment of the number of feedbacks is completed and the YD61016LN-GND automa cally exits the configura on mode. Achtung! Alle Anschlussarbeiten am YD61016LN-GND müssen immer im spannungslosen Zustand erfolgen. Spannungsversorgung vom Netzt trennen und die Zentrale abschalten! www.yamorc.de P 10...
  • Page 11: Use The Yd61016Ln-Gnd To Configure The Switching Decoder Of The Yd8Xxx Series

    -LINK or the YD6902ES-EXT connec on set. Voltage source USB-Isolator (op onal) Power supply 12-19 VDC Transformer 10- 16 VAC Op onal for tes ng the Configura on Digital control unit Track voltage connec on (Track Out) www.yamorc.de P 11...
  • Page 12: Firmware Update Of The Switching Decoders Of The Yd8Xxx Series Via "Es-Link" With The Yd61016Ln-Gnd

    To prevent ground loops via USB, the YD61016LN-GND should always be connected to the PC or laptop via USB alone.  The YD61016LN-GND is connected via "ES-IN Link" and the "ES-PGM Link" socket on the YD8xxx. The connec on can be made either via the YD6901ES  -LINK or the YD6902ES-EXT connec on set. www.yamorc.de P 12...
  • Page 13: Warranty

    Content of the guarantee/exclusions: The warranty includes, at YaMoRC's discre on, the free repair or free replacement of the defec ve part, which can be proven to be due to design, manufacturing, material or transport faults. For this purpose, you must send the decoder to us properly stamped. Further claims are excluded.

Table of Contents