CORESYNC POWER OVER ETHERNET GATEWAY UNREGULATED 2.0 90W
RJ45 Connector for PoE input over
CAT5e (PoE rated)/CAT6/CAT6A
Link Speed Indication – Active when
operating speed is 100Mbps
Link Activity Indicator – Blinks when
detecting activity on the network
Power Indicator LED
ENGINEERING RECORD
NO : 715900
MPN/FMT-042 (2019/DEC/23 REV-03).
THIS INFORMATION IS CORRECT AS AT THE TIME OF PUBLICATION, SPECIFICATION ARE SUBJECT TO CHANGE.
INSTALLATION INSTRUCTIONS
Order No.
1807981000
SAP NO : 1807981000
CoreSync Gateway 90W 802.3bt, Silver Metal
Doc No: 1807981000
http://www.molexces.com
BEFORE INSTALLING OR ADJUSTING THIS PRODUCT,
PLEASE READ THESE INSTRUCTIONS CAREFULLY.
PLEASE KEEP THIS GUIDE FOR FUTURE REFERENCE
4-pin Micro-Fit 3.0 Connector
for CoreSync Bus
42-57 VDC + RS485 Data line
Description
Doc part: AS
REV- B
SHEET No. 1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CORESYNC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for molex CORESYNC

  • Page 1 BEFORE INSTALLING OR ADJUSTING THIS PRODUCT, INSTALLATION INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY. PLEASE KEEP THIS GUIDE FOR FUTURE REFERENCE CORESYNC POWER OVER ETHERNET GATEWAY UNREGULATED 2.0 90W RJ45 Connector for PoE input over CAT5e (PoE rated)/CAT6/CAT6A Link Speed Indication – Active when 4-pin Micro-Fit 3.0 Connector...
  • Page 2 This product should only be serviced by a CoreSync Certified Technician.  UL 2108 listed, Certified to CAN/CSA standard C22.2 No. 250.0, Plenum rated GATEWAY MUST BE INSTALLED BY A CORESYNC CERTIFIED TECHNICIAN OR QUALIFIED ELECTRICIAN (CHECK WITH LOCAL AND NATIONAL CODES FOR PROPER INSTALLATION)
  • Page 3 Step 1: Refer to the dimensions and mounting patterns below to mount the 90W 802.3bt Gateway. Dimensions for CoreSync 90W 802.3bt Gateways: Mounting pattern for CoreSync 90W 802.3bt Gateways: Step 3. Use #8 self-tapping screws to mount the 90W Gateway as shown below (Screws not provided). It is recommended that the Gateway is not connected to earth ground.
  • Page 4 Step 4. Make sure the CoreSync bus is connected before plugging in the PoE cable. Use CAT5E or CAT6 cable*. The maximum length of cable should not exceed 100 meters. (DO NOT CONNECT OR DISCONNECT CORESYNC BUS WHILE DEVICE IS POWERED) *Please note the Power LED indicator will turn on once you have power.

This manual is also suitable for:

Coresync 1807981000

Table of Contents