6.5 Setting of the system pressure
Once flushing is complete, the diagram expansion tank
has to be connected to the connection set respectively
the safety group. The required inlet pressure of the
diaphragm expansion tank has to be determined first
and the tank has to be filled with nitrogen accordingly.
The required inlet pressure of the
diaphragm expansion tank as well as the
system pressure depends on the spatial
and performance-related parameters of the
solar plant. The technical service of the
company Oventrop will support you in the
design of an energy efficient solar plant and
the determination of all required operating
pressures.

7 Operation

7.1 Bleeding the system
Before initial operation, the system must be filled and
bled with due consideration of the permissible
operating pressures.
Illustr. 7.1 Bleeding at the vent pot ("Regusol LH")
7.2 Correction factors for mixtures of water and
glycol
The correction factors of the manufacturers of the
antifreeze liquids have to be considered when setting
the volume flow.
24

8 Accessories

Compression fittings: For the connection of the solar
station to the pipework.
Locking shackle: For the connection of the solar
station to a flexible pipework (e.g. corrugated metal
hoses); in addition to the wall bracket included in the
delivery.
"Regusol" filling pump: For manual filling of the solar
plant with small quantities of heat transfer medium
from an external storage basin.
"Regusol" flushing and filling station: For flushing,
filling and bleeding of solar thermal plants.
The complete range of accessories can be found in
the catalogue.

9 Maintenance

The station is maintenance-free.
Tightness and function of the station and its
connection points have to be checked regularly during
maintenance. The station must be easily accessible.