consumes a fair amount of quiescent current, it is recommended that the on time
be as short as possible.
Press ENTER key to enter the setting and press UP and DOWN key to turn off
from NEVER (always on) or 1 to 10 minutes in 1 minute increments.
Note: When the backlight turns off, pressing any key will turn it back to U-00 display
screen.
O-06: Fan Test
Use Constant O-06 to test if the fan can be forced to be ON or OFF.
When FAN ON is selected, the fan test is conducted as the O-06 screen remains.
Once the screen leaves O-06, it will stop the test running.
O-07: Software Version
The software version displayed is important and useful when contacting Rich
Electric Technical Support.
O-08: ***Bootloader***
This is the Bootloader initiation display. It is only used to update the firmware.
G-01: EnergyHarvest Today 1
This screen displays how much the solar energy was harvested "Today" in kWHr
and AHr unit.
G-02: EnergyHarvest Today 2
This screen displays how much time the charger was in Float mode "Today".
It is valuable to know that the charger enters Float mode because this is a clear
indication that the batteries have been fully recharged. If the value displayed in
"G-02=FLOAT " is consistently 00.00 Hr, it means that the PV array is not
sufficiently sized to keep up with the load. Use a generator for additional battery