Your new Verilux CleanWave Sanitizing Wand kills up to 99.9%† of germs, allergens and odor causing bacteria on hard surfaces.†
We hope you enjoy this product and use it frequently. Your results will be cumulative – your "kill rate" may be 90% during your first use on a surface, then "90% of the remaining 10%" on your next use.
Visible light is electromagnetic wavelengths visible to the human eye. The wavelength of visible light, in nanometers, is about 400nm to 750nm. A nanometer is one billionth of a standard metric meter.
Ultraviolet or UV light is the part of the electromagnetic spectrum – from about 10nm to 400nm – that contains frequencies just higher than visible light.
Ultraviolet light was discovered by German physicist Johann Ritter. In 1801, Ritter was experimenting with silver chloride, a chemical known to break down when exposed to sunlight. He found that light at the blue end of the spectrum increased the reaction.
Experimenting further, he discovered that the reaction was even more efficient when exposed to light beyond blue – light that was invisible. He called this new type of light ultraviolet, meaning "beyond the violet" (ultra comes from the Latin for "beyond").
UV light is invisible to humans, but birds and some species of insects, snakes, turtles and fish can see ultraviolet light.
UV light can be divided into various wavelength bands with differing characteristics.
The Sun emits ultraviolet radiation in UV-A, UV-B and UV-C bands, but because of absorption in the ozone layer, 99% of the ultraviolet radiation that reaches Earth is "long wave" UV-A.
UV-A, also known as "black light," creates fluorescent effects at your local disco and "midnight bowling" sessions as UV light (which cannot be seen) is absorbed by materials and re-emitted in the visible range.
UV-B "medium wave" rays both help and hurt. Too much UV-B exposure causes sunburn and can damage human tissue. Too little UV-B exposure leads to a lack of Vitamin D absorption in animals.
The higher energy "short wave" UV-C band rays (100 to 280 nanometers) are lethal to micro–organisms. This range is known as the Germicidal Spectrum. UV-C light sanitizes micro-organisms and biological pollutants, including viruses, bacteria, germs, mold, dust mite and flea eggs by penetrating their cell membranes and attacking and deactivating their cellular DNA, stopping their reproductive capabilities and killing them.
The scientific community has long known that UV-C light acts as a natural sanitization system. Hospitals, food processing facilities, scientific laboratories, water treatment plants and air handling systems use UV-C light to eliminate contaminants and germs.
The Verilux CleanWave Sanitizing Wand provides that same UV-C ultraviolet technology for use in your home and on the road.
†Kills up to 99.9% of germs, viruses and other micro-organisms on solid, non-porous surfaces. Sanitizing times and effectiveness for porous surfaces may vary.
†Kills up to 99.9% of germs, viruses and other micro-organisms on solid, non-porous surfaces. Sanitizing times and effectiveness for porous surfaces may vary.
‡Based on exposure of UV-C light to test organisms in laboratory on non-porous hard surface, under controlled conditions. MRSA refers to Methicillin Resistant Staphylococcus Aureus (ATCC 33592). H1N1 refers to A/Swine/Iowa Swine Influenza A (ATCC 333).
*Direct UV-C Light exposure is effective on certain allergen producing organisms such as Mold A and in reducing dust mites.
§When used as directed.
Your new Verilux CleanWave Sanitizing Wand kills up to 99.9%† of germs, allergens* and odor causing bacteria**. Use it to sanitize surfaces throughout your home without chemicals, irritants§ or residues. Laboratory proven to eliminate up to 99% of MRSA and H1N1 in just 1 second‡ the CleanWave is ideal for countertops, computer keyboards, cell phones, pillows, crib and mattress covers, upholstery, pet beds, area rugs, surfaces in the baby's room and more.
This Wand features:
†Kills up to 99.9% of germs, viruses and other micro-organisms on solid, non-porous surfaces. Sanitizing times and effectiveness for porous surfaces may vary.
‡Based on exposure of UV-C light to test organisms in laboratory on non-porous hard surface, under controlled conditions. MRSA refers to Methicillin Resistant Staphylococcus Aureus (ATCC 33592). H1N1 refers to A/Swine/Iowa Swine Influenza A (ATCC 333)
*Direct UV-C Light exposure is effective on certain allergen producing organisms such as Mold A and in reducing dust mites.
§ When used as directed.
Safety Feature
An internal safety switch will automatically turn the unit off if the light source is turned upward in order to help protect eyes and skin from exposure.
NOTE: The safety mechanism includes a switch that will make a slight rattling sound — this is a normal function.
The battery pack is shipped separately from the Sanitizing Wand. Before using the Sanitizing Wand, install the battery pack and fully charge the Wand.
NOTE: Be sure the charger is unplugged before installing a new battery pack.
NOTE: Used batteries should be disposed of properly and never incinerated.
NOTE: The Sanitizing Wand contains a rechargeable 4.8V Nickel Metal Hydride (NiMH) battery pack made only by Verilux. Do not attempt to replace with other brands. To order a new battery, call Verilux customer service at 1-800-786-6850.
It takes approximately 14 hours to fully charge the battery for the first time.
Only the wand adapter provided with the device should be used.
When the battery is low and requires charging, the Wand will beep 10 times and the red LED will flash 10 times.
Timer
During operation, a count-up timer shows total sanitizing time. The display increments each second to 59, then briefly displays the minutes elapsed before starting another 59-second count-up. The next minute reached is then shown briefly and the count-up begins again. This cycle repeats for 99 minutes or until the Wand requires charging.
To see the current minute of sanitizing time, quickly press and release the blue button.
For example, if you've been using the Wand for 3 minutes and 20 seconds, the Wand will show "20." Press the button and the display will briefly show "03" before continuing the by-the-second count-up to minute "04."
Step by step:
NOTE: Be sure the Wand is facing downward, directly over your desired sanitizing area. A safety switch will automatically turn off the UV-C light if the Wand is tilted upward from the horizontal position (the counter will not stop during this temporary bulb safety shut-off).
When the battery charge is low, the Wand will begin to beep and the red indicator light will flash, indicating that the battery needs to be charged.
*Calculation based on eliminating 99.9% of Influenza A on standardized solid items and surfaces.
Using the Wand in Charging Mode
The Wand can be used in charging mode simply by connecting the power adapter to the Wand and following the Operation Instructions.
Even with regular use, it is unlikely that you'll ever need to replace the long-life Verilux bulb. If you do need to replace a bulb, use only Verilux bulbs. Use of a non-Verilux bulb can result in damage to the Wand or the bulb.
To order a replacement bulb, use the Component Re-order form included with this product. Or call Verilux Customer Service at 1-800-786-6850 or visit www.verilux.com.
This this product should not be handled or used by children to prevent accidental exposure to UV-C rays.
Environment
Operating Temperature: 15°C to 35°C (59°F to 95°F)
Storage Temperature: 0°C to 40°C (32°F to 104°F)
Relative Humidity: 5% to 95% non-condensing
UV-C Bulb
Replacement bulb: 4 Watt UV-C bulb (replace with Verilux brand only)
Battery
4.8V, 1500mAh NiMH battery pack
Power Supply
Input Power: 100-240 VAC, 50/60 Hz, 0.5 A
Output Power: DC 6.5V 1.5A
Conforms to CEC Class V efficiency classification.
Always direct the UV-C light AWAY from the eyes and skin. Direct prolonged exposure of eyes or sking to the UV-C light bulb can cause serious skin burn and eye inflammation from short wave ultraviolet radiation. Radiation from these lamps is harmful to the eyes and skin.
POTENTIAL MOLD SPORE RELEASE
Application of UV-C light to existing mold growth can cause respiratory irritation and allergic symptoms. Do not use UV-C light where active mold growth exists. Remove active mold growth from surfaces prior to exposure.
SAVE THESE INSTRUCTIONS
Many questions may be answered by visiting www.verilux.com, or you may call our Customer Service Department at 1-800-786-6850 during normal business hours.
This limited warranty is provided by: Verilux, Inc., 340 Mad River Park, Waitsfield, VT 05673
To obtain a Return Authorization, please contact the Verilux Customer Service Department at 1-800-786-6850, or http://www.verilux.com/customer-service-form.
If, during the first year of ownership, this product fails to operate properly, it should be returned as specified at www.verilux.com/warrantyreplacement or as instructed by a Verilux customer service representative at 1-800-786-6850.
Please visit our web site at: www.verilux.com or call 1-800-786-6850
Representatives are available Monday — Friday, 9am — 5pm EST
verilux
340 Mad River Park, Waitsfield, VT 05673
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Verilux CleanWave VH01 - UVC Sanitizing Wand with CleanWave Technology Manual
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the CleanWave VH01 that isn't answered in the manual? Leave your question here.