Advertisement

Quick Links

OWNER'S
MANUAL
INSTALLATION, OPERATION, & PARTS
FPP-72743 / 72744
MANUFACTURED BY:
NINGBO SPLASH POOL APPLICANCE CO., LTD
To prevent potential injury and to avoid unnecessary service calls, read this manual
carefully and completely.
SAVE THIS INSTRUCTION MANUAL
Use of appointed replacement parts voids warranty.
ATTENTION INSTALLER – THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE
INSTALLATION, OPERATION, AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END
USER OF THIS PRODUCT. FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN
SERIOUS INJURIES.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FPP-72743 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ningbo FPP-72743

  • Page 1 MANUAL INSTALLATION, OPERATION, & PARTS FPP-72743 / 72744 MANUFACTURED BY: NINGBO SPLASH POOL APPLICANCE CO., LTD To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely. SAVE THIS INSTRUCTION MANUAL Use of appointed replacement parts voids warranty.
  • Page 2: Chapter One: Important Safety Instuctions

    Symbol means: will DANGER This symbol indicates that in case of failure it is a potential hazard: It cause severe personal injury or death or property damage. could WARNING This symbol indicates that in case of failure it is a potential hazard: It result in severe personal injury or death or property damage.
  • Page 3 WARNING Suction Entrapment Hazard. 11. Suction in a suction inlet and/or suction inlet cover, which are damaged, broken, cracked, missing, or unsecured cause severe injury and/or death due to the following entrapment hazards: Hair Entrapment- Hair can become entangled in suction inlet cover. Limb Entrapment- A limb inserted into an opening of a suction inlet or in a suction inlet cover that is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb.
  • Page 4: Chapter Two: Installation Instructions

    CHAPTER Two: Installation Instructions WARNING This product should be installed and serviced only by a qualified professional. Pump Location DO NOT install pump in a damp or non-ventilated location. Keep motor clean. Pump motor requires free circulation of air for cooling. Pump Mounting Install pump on a firm, level base or pad to meet all local and national codes.
  • Page 5 consult electrician to inspect and repair electrical system. WARNING Fire Hazard. 5. Match supply voltage to motor nameplate voltage. Insure that the electrical supply available agrees with the motor’s voltage, phase, and cycle, and that the wire size is adequate for the H.P. (KW) rating and distance from the power source. NOTE - All electrical wiring MUST be performed by a licensed electrician, and MUST conform to local codes and NEC regulations.
  • Page 6 CHAPTER Four: Start-Up & Operation Prior to Start-Up Notice: If it is necessary to perform a pressure test, prior to initial use to ensure pump is functioning properly, then the following criteria should be maintained for this test: 1. Have a professional perform this test. 2.
  • Page 7: Chapter Seven: Troubleshooting

    WARNING Separation Hazard. 1. Do not purge the system with compressed air. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, filter, or piping.
  • Page 8: Chapter Eight: Technical Data

    1. Empty pump/strainer housing. Solution: Make sure pump/strainer housing is filled with water and cover O-ring is clean. Ensure O-ring is properly seated in the cover O-ring groove. Ensure O-ring is lubricated and that strainer cover is locked firmly in position.
  • Page 9: Chapter Nine: Warranty

    Pump performance table Pump model Volt / HZ Amps Q (GPM) Remark FPP-72743 1.0 HP 115/230V 11.5/5.7 FPP-72744 1.5 HP 115/230V 14/7 CHAPTER Nine: Warranty LIMITED WARRANTY To original purchasers of Distinction pumps and filters, the manufacturer warrants his products to be free from defects in materials and workmanship for a period of TWO (2) years from the date of purchase.
  • Page 10 CHAPTER Ten: Pump structure & parts Pump models:FPP-72743 / 72744 Ref. Part No. Description 647252772 Cover 65431042080 O-ring 647252704 Basket 647254201 Pump housing 65431032080 O-ring 647254203 Diffuser 647274271 Impeller for 72742/72745 647274371 Impeller for 72743/72746 65431075080 O-ring 647254202 Pump cover...