Kruger KRAI100OIL Operator And  Maintenance Manual

Kruger KRAI100OIL Operator And Maintenance Manual

Industrial vacuum cleaner

Advertisement

Quick Links

KRAI100OIL
Industrial vacuum cleaner
Operator's and maintenance manual
Original and official manual
Read this manual carefully before using the vacuum cleaner

Advertisement

Table of Contents
loading

Summary of Contents for Kruger KRAI100OIL

  • Page 1 KRAI100OIL Industrial vacuum cleaner Operator’s and maintenance manual Original and official manual Read this manual carefully before using the vacuum cleaner...
  • Page 2 In case of any doubts, always immediately phone the After-Sales Service. The competent Law Court for all disputes is that of PAMPLONA (Spain). The manual must be kept with the vacuum cleaner in case of resale! www.kruger.es...
  • Page 3: Table Of Contents

    Description of controls Work cycle Manual emptying of the container Discharging of the container by means of the reversed air flow valve Maintenance section Informative notes General safety warnings Maintenance operations Replacing the filters Troubleshooting Spare parts section Recommended spare parts www.kruger.es...
  • Page 4: Information Section

    Information Section Identification of main parts Reversed air flow valve Release fastening Suction point Push handle Level indicator Fixed wheels Vacuumed material container Castors Switch www.kruger.es...
  • Page 5: Accessories Provided

    Information Section Accessories provided FI.0284.0000- D. 477 H. 175 20 MICRON SUPERWEB 3D FILTER (ONLY SPARE PART) www.kruger.es...
  • Page 6: Identification Details Of Manufacturer

    Identification details of manufacturer KRÜGER TECHNOLOGY S.L. Pol. Agustinos C/G Parc. B2 31013 Pamplona (Navarra) SPAIN Tel. +34 948 343 393 www.kruger.es info@kruger.es Marking plate In compliance with the Machine Directive 2006/42/CE on vacuum cleaners, the machine is fitted with CE plates.
  • Page 7: Intended Uses

    Before scrapping, all plastic and rubber parts will have to be separated from the electrical material. Parts made of plastic, aluminium and steel only may be recycled if collected by special centres. www.kruger.es...
  • Page 8: Technical Details

    Information Section 1.10 Technical details KRAI100OIL Power Voltage Volts Max. vacuums rate 3.000 Max. air flow rate Noise level Filter type SUPERWEB 3D Capacity Suction inlet Ø Dimensions 67 X 66 x 125 www.kruger.es...
  • Page 9: Warranty

    All disputes shall be referred to the Law Court of Pamplona (Spain). The manufacturer declines all liability in the following cases:  Failure to send the warranty Certificate  Failure to follow the instructions  Use of non-original spare parts  Failure to service the machine properly www.kruger.es...
  • Page 10: Safety Section

    KRÜGER TECHNOLOGY S.L., make sure no hazards exist for operators and others. Only ever use original KRÜGER TECHNOLOGY S.L. spare parts. KRÜGER TECHNOLOGY S.L. declines all liability in the event of non-original spare parts being used. www.kruger.es...
  • Page 11: Safety Warnings

    The machine casing containing moving parts must not be removed by the user. When using the machine, mind other people, especially children. Use the machine cautiously on slopes and ramps. Do not change direction on gradients. Make sure the parked machine remains stable by operating the braked wheel. www.kruger.es...
  • Page 12 Avoid prolonged contact with solvents and inhaling their vapours. Avoid use close to open flames or sources of heat. Never use the vacuum cleaner without the filter. Do not vacuum lit cigarette ends. The filter could be damaged. Do not vacuum petrol or flammable liquids in general. www.kruger.es...
  • Page 13 Only adult persons should use the vacuum cleaner. During vacuuming operations, always brake the vacuum cleaner using the special revolving wheel lock. www.kruger.es...
  • Page 14: Safety Plates And Symbols

    Replace the damaged plates with new ones supplied by KRÜGER TECHNOLOGY S.L.. If a plate is affixed to a replaced part, make sure a new plate is affixed to the new part. Attention! Read the operator's and maintenance manual carefully before using the cleaner or doing any maintenance jobs. www.kruger.es...
  • Page 15: Outstanding Risks

    Applied directives The following directives apply to the vacuum cleaner described in this manual:  2006/42/CE Machine Directive  2014/30/EU Electromagnetic compatibility directive  2014/35/EU Low-voltage directive www.kruger.es...
  • Page 16: Installation Section

    (cm) (cm) (cm) KRAI100OIL The machine is supplied in a strong cardboard box secured with straps. Transport the package using a fork-lift truck of adequate lifting capacity and make sure it is stable and that weight is properly distributed on the forks.
  • Page 17: Installation

    Note: No standard accessories (reducers, hoses, nozzles) are included with the vacuum; accessories must be specified and ordered separately. Contact your dealer for information relating to the different types of optional accessories available for this specific vacuum cleaner model. Fit the supplied pipe on the connector. www.kruger.es...
  • Page 18 If, when the vacuum cleaner is switched on, the inlet blows air out instead of sucking it in, the machine will have to be switched off, the plug detached from the power socket and the direction of rotation of the motor changed by modifying the plug using a screwdriver. www.kruger.es...
  • Page 19: Operation Section

    Operation Section Description of controls STOP POSITION START POSITION www.kruger.es...
  • Page 20: Work Cycle

    To stop the vacuum cleaner, press the Stop button. Warning! Before switching the vacuum cleaner back on, make sure the motors have come to a complete halt.  After finishing work, disconnect the vacuum cleaner from the power socket. www.kruger.es...
  • Page 21 To move the vacuum cleaner, use the large handle. Warning! The vacuum can be moved only on flat ground! If the vacuum is moved on inclined grounds, you can risk to lose the control, because of the weight, and to damage persons or things. www.kruger.es...
  • Page 22: Manual Emptying Of The Container

    Operation Section Manual emptying of the container  Stop the vacuum motors by pressing the relevant STOP buttons. Important! Disconnect the plug from the power socket.  Block the vacuum cleaner.  Lift the provided handle to release the container. www.kruger.es...
  • Page 23 Never put your hands between the collection container and the vacuum when positioning and securing the collection container: this operation must be executed throughout the coupling side levers or the handle using BOTH YOUR HANDS to control them. www.kruger.es...
  • Page 24: Discharging Of The Container By Means Of The Reversed Air Flow Valve

    Block the vacuum cleaner.  Start the discharging tool on  Reverse the suction air flow by spinning the provided lever and the suction valve on the DISCHARGE, as explained by the provided labels stuck on the suction motor. www.kruger.es...
  • Page 25 When finishing the discharging operation, turn off the motor by means of the STOP switch and replace the levers on the SUCTION position. Important! All the material must be disposed of through authorised channels in the country where the vacuum cleaner is used. www.kruger.es...
  • Page 26: Maintenance Section

    Work done on motors or other electrical component parts must only be performed by a specifically trained electrician, authorised by the Safety Manager. Always use tools that are in perfect condition and specifically made for the operation to be done. The use of unsuitable tools or tools not in good condition could cause serious damage. www.kruger.es...
  • Page 27: Maintenance Operations

    If the flexible hose is perforated, the power of the cleaner will be reduced and dust and liquids will leak into the environment. Warning! All maintenance and repair jobs must be performed directly by KRÜGER TECHNOLOGY S.L. or its authorised dealers. www.kruger.es...
  • Page 28: Replacing The Filters

    Disconnect the vacuum cleaner plug from the power socket. Important! Wear individual protection devices.  Block the vacuum cleaner by means of the retainer. Release the stops that hold the head.  Remove the hose that connects the motor to the filter chamber. www.kruger.es...
  • Page 29 All the material trapped by the filter and the filter itself must be disposed of through authorised channels in the country where the vacuum cleaner is used ATTENTION! The filter must be periodically clean, in order to prevent the obstruction and the significant reduction of the vacuum cleaner’s performance. www.kruger.es...
  • Page 30: Troubleshooting

    Air leak Check for any air leaks out of closing fasteners, tightening screws, container or filter chamber Contact KRÜGER TECHNOLOGY S.L. after-sales Motor very noisy Warning! For any other problems, contact the KRÜGER TECHNOLOGY S.L. after-sales service. www.kruger.es...
  • Page 31: Spare Parts Section

    Spare Parts Section Recommended spare parts Code Description SL.0222.0000 D. 500 FILTER CLAMP FI.0284.0000 D. 477 H. 175 20 MICRON SUPERWEB 3D FILTER GI.0054.0000 D. 500 SYLICON FILTER GASKET GI.0141.0000 3X30 ADHESIVE MOUSSE GASKET www.kruger.es...
  • Page 32  Pamplona, a 17 de febrero 2023 Javier Cucalón DIRECTOR GERENTE...