ADJUSTMENT OF THE DOOR
Before carrying out the following Instruction you must ensure that the appliance is DISCONNECTED
from the electricity supply.
Occasionally door adjustment may be necessary
i.e. if a slight clearance is noticeable between the
door gasket and cabinet. This condition is mainly
due to uneven floors or the loading of the door. It is
possible to adjust the door at the hinge point (Fig.
7) as follows:
1. With the appliance standing on a level surface,
check that the door opens and closes properly and
seals all round.
2. If adjustment of the door is necessary this can
be done by loosening the screw (A) Securing the
hinge blade to the foot and, adjusting the hinge
blade and door in and out,a little at a time, to
tighten or loosen the fit. Re-tighten the screw each
time an adjustment has been
made before again
checking for satisfactory door closure.
ELECTRICAL CONNECTIONS
|
=
WARNING: THIS APPLIANCE MUST BE EARTHED.
The manufacturer declines any liability should this safety measure not be observed.
ELECTRICAL REQUIREMENTS
Before switching on, make sure that the voltage of
your electricity supply is the same as that indicated
on the rating plate, located inside the cabinet.
WARNING! THIS APPLIANCE MUST
BE EARTHED
For your convenience, this appliance comes
complete with either a moulded-on or re-wireable
13 amp (BS1363) plug, protected by a 13 amp
ASTA approved (BS1362) fuse.
i
in the event of having to change the fuse in the
plug supplied, a replacement 13 amp ASTA
approved (BS1362) fuse must be used.
In the case of a moulded-on plug, the fuse cover
MUST be refitted after changing the fuse. If the
fuse cover is lost or damaged the plug MUST NOT
be used until a replacement is obtained.
Replacement covers are available from your local
electricity shop or nearest customer service centre.
The colour of the replacement fuse cover must
match the colour insert or emboss on the base of
the plug.
in the case of a re-wireable plug, care must be
taken to ensure that the top cover is refitted without
causing damage to either the top cover or base. In
the event of the plug becoming damaged or
cracked, it must be replaced with an equivalent 13
amp, BS1363 approved plug (ref. fig.9) and rewired
using the following procedure:-
IMPORTANT
The wires in the mains lead are coloured
in
accordance with the following code:
GREEN & YELLOW
: EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
The wire coloured green and yellow must be
connected to the terminal marked with the letter "E"
or by the Earth Symbol =
or coloured green or
green and yellow. The wire coloured Blue must be
connected to the terminal marked with the letter
"N" or coloured black. The wire coloured Brown
must be connected to the terminal marked "L" or
coloured red.
Upon completion there must be no cut, loose or
stray strands of wire present and the cord clamp
must be secure over the outer sheath.
If a 13 amp (BS1363) plug is unsuitable for your
sockets, the plug should be removed, (cut-off in the
case of a moulded-on
plug) and an appropriate
plug fitted.
NOTE: Moulded plugs cannot be re-used and
should be discarded if cut from a mains lead,
as insertion into а
13 A socket could prove
fatal.
If a non-fused plug is fitted (ref. fig.8), the wiring
must follow the above procedure and the appliance
must be protected by the use of a 15amp fuse
either in the adaptor or at the distribution board.
If at any time a replacement
supply cord is
required, the cross sectional area of its conductors
must not be less than 0.75mm? and the cable
clamp must be tightened so as to fully retain the
new cord.
We recommend that this type of installation be
checked by a fully qualified electrician, prior to use.