MoUnt tHe Unit

All Units
1. Set downdraft into opening. Extend leveling brackets to floor of
cabinet so downdraft sits straight. (Note: Leveling brackets can
be removed and re-attached in other positions. Bottom flange
may have to face inward in tight cabinet installations.)
2. Secure the downdraft to the countertop as follows: Hold the
downdraft against the back of countertop cut-out and tightening
the two mounting screws (one on each end of unit) on underside
of countertop. Use a wood shim between screw and underside
of granite countertops.
3. Screw leveling brackets to bottom of cabinet. Tighten screws
holding leveling bracket to unit on each side.

inStaLL DUctWork

Interior Blower Installation
 BLOWER 
COLLAR
SCREWS
1. Cut hole in cabinet as well as holes in wall or floor as necessary.
2. Mount the roof or wall cap and work back towards the cabinet,
attaching all ductwork, elbows and transitions as previously
planned. Tape all ductwork connections to make them secure
and air tight.
3. Connect ductwork (and transition, if required) to downdraft. If
necessary, LOOSEN nuts and screws that hold the blower in
place, and slide blower left or right to meet ductwork. Re-tighten
screws and nuts.
note: A 3-1/4" x 10" collar is provided for installers who prefer to
rivet the ductwork to the unit. This will allow blower to be removed and
replaced easily in service situations without disturbing ductwork.
- FLANGE FACING OUT
LEVELING BRACKET
- FLANGE FACING IN
!
caUtion:
BeFore cUtting HoLe in
caBinet For DUctWork,
check for interference with floor
joists, wall studs, electrical wir-
ing, or plumbing.
3-1/4" X 10"
TO 6" RD.
TRANSITION
6" RD. ELBOW
& DUCTWORK
1. Cut hole in cabinet as well as holes in wall or floor as necessary.
2. Mount the exterior blower and work back towards the cabinet,
3. Connect ductwork to downdraft. If necessary, LOOSEN nuts and
7
downdraft Ventilators
MOUNTING SCREWS
LEVELING BRACKET
Exterior Blower Installation
ELBOW
0" ROUND DUCT
attaching all ductwork, elbows and transitions as previously
planned. Tape all ductwork connections to make them secure
and air tight.
screws that hold remote blower adapter plate in place, and slide
outlet assembly left or right to meet ductwork. Re-tighten screws
and nuts.