Mitsubishi Electric Mr. Slim PUZ-M200YKA2.UK Service Manual page 62

Table of Contents

Advertisement

Type of
Switch No.
Switch
1
2
SW5
3,4,5
6
1
2
3
Max Hz setting (cooling)
SW7*
4
4
Max Hz setting (heating)
5
6
1
SW8
2
3
1
SW9
2
3,4
DIP
switch
1
2
3
4
SW6
5
6
7
8
*
2
'Power failure automatic recovery' can be set by either remote controller or this DIP SW. If one of them is set to ON, 'Auto
recovery' activates. Please set "Auto recovery" basically by remote controller because all units do not have DIP SW.
Please refer to the indoor unit installation manual.
*
3
SW7-1 is setting changeover of Demand/Low noise. It is effective only in the case of external input.
(Local wiring is necessary. Refer to the next page: Special function)
*
4
Please do not use SW7-3 to 7-6 usually. Trouble might be caused by the usage condition.
*
5
SW5-1 to 5: Function switch
OCH775B
Function
No function
Power failure
automatic recovery *
2
No function
No function
Mode select *
3
No function
Max Hz (cooling)
Max Hz (heating)
No function
Defrost setting
No function
No function
No function
No function
Function switch
No function
No function
MODEL
Model select
Action by the switch operation
ON
Auto recovery
No auto recovery
Demand function
Low noise mode
0.8
×
0.8
×
For high humidity
Valid
SW6
ON
200Y
OFF
1 2 3
4 5
4
6
7
8
ON
250Y
OFF
1 2 3
4
4 5
6
7
8
The black square (
62
Effective timing
OFF
When power supply ON
Always
Normal
Always
Normal
Always
Normal
Always
Normal
Always
) indicates a switch position.

Advertisement

Table of Contents
loading

Table of Contents