Ebyte E90-DTU Manual page 18

Hide thumbs Also See for E90-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Read/W
05H
REG2
rite
Read/W
06H
REG3
rite
Copyright ©2012–2023, Chengdu Ebyte Electronic Technology Co.,Ltd.
1
enable
1
0
firing power
0
0
0
1
41.5±0.5dBm (default)
1
0
1
1
Channel Control (CH)
0-83 represent a total of 84 channels respectively
E90-DTU(400SL42)
0~44 represent a total of 45 channels respectively
E90-DTU(230SL42)
7
Enable RSSI bytes
0
Disable (default)
1
enable
6
transmission method
0
Transparent transmission (default)
1
fixed-point transmission
5
relay function
0
Disable trunking (default)
1
Enable relay function
40dBm
E90-DTU(xxxSL42) User Manual
working status to print
the
corresponding
different format log,
for
details,
see
section 6.5, abnormal
working
status
log
printing details.
Power and current
are
nonlinearly
related, and the
power
supply
is
most efficient at
maximum power.
Current does not
decrease
proportionally
with
power
reduction
Actual frequency =
410.125 + CH*1.0M
Actual Frequency =
225 + CH*0.25M
When enabled, the
module
receives
wireless
data,
which will follow
an RSSI intensity
byte when output
through the serial
port TXD.
The
module
will
recognize
the
first three bytes
of the serial port
data as: address
high + address low
+
channel,
and
will use it as the
wireless transmit
target.
When the relay
function is
enabled, the
module will
initiate a
forwarding if the
destination
address is not the
module itself.
In
order
to
prevent
data
backhauling, it is
recommended to use
it in conjunction
with
fixed-point
16