Ebyte E90-DTU Manual page 16

Hide thumbs Also See for E90-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Read/W
02H
NETID
rite
Read/W
03H
REG0
rite
Copyright ©2012–2023, Chengdu Ebyte Electronic Technology Co.,Ltd.
NETID(default 0)
7
6
5
UART serial port rate (bps)
0
0
0
Serial port baud rate of 1200
0
0
1
Serial port baud rate of 2400
0
1
0
Serial port baud rate of 4800
0
1
1
Serial port baud rate of 9600(default)
1
0
0
Serial port baud rate of 19200
1
0
1
Serial port baud rate of 38400
1
1
0
Serial port baud rate of 57600
1
1
1
Serial port baud rate of 115200
4
3
serial port parity bit
0
0
8N1(default)
0
1
8O1
1
0
8E1
1
1
8N1(Equivalent to 00)
Wireless air rate (bps)
2
1
0
E90-DTU(230SL42)
0
0
0
Air rate 0.3k
0
0
1
Air rate 0.6k
0
1
0
Air rate 1.2k
0
1
1
Air rate 2.4k
E90-DTU(xxxSL42) User Manual
E90-DTU(400SL42)
Air rate 0.3k
Air rate 1.2k
Air rate 2.4k
(default)
Air rate 4.8k
to FFFF, it can be
used
as
a
broadcast
and
listen
address,
i.e.: the module
will
not
be
address filtered
in this case1
Network
address
for
distinguishing
networks.
It
should be set to
the
same
when
communicating
with each other.
Two
modules
communicating
with
each
other
can have different
serial port baud
rates.
The
checksums can also
be different.
When transmitting
larger
data
packets
continuously,
users
need
to
consider
data
blocking and even
possible loss due
to the same baud
rate.
It
is
generally
recommended
that
the baud rates of
both sides of the
communication are
the same.
Both sides of the
communication
must be the same.
The
higher
the
rate,
the
lower
the delay and the
shorter
the
distance.