Sony Professional U-matic SP BVU-950 Maintenance Manual page 174

Table of Contents

Advertisement

11-20.
REC
BIAS
CURRENT
LEVEL
ADJUSTMENT
(SP)
machine
conditions
for
adjustment
spec.
adjustment
* AUDIO
IN
connector:
1kHz/
7kHz,
— 80dBm
-Set
the
KSP
cassette
tape.
¢ Play back the self recorded tape.
LINE
OUT
connector
(terminated
by
6000)
1kHz =0(REF)
7kHz =O0+ 0.5dB
CH-1:
@RV103/AU-85(C-1)
CH-2:
@RV105/AU-85(E-1)
REC
mode — adj.
PB
mode — check
11-21.
REC
BIAS
CURRENT
LEVEL
ADJUSTMENT
(CONVENTIONAL)
machine
conditions
for
adjustment
spec.
adjustment
*AUDIO
IN
connector:
1kHz/
7kHz,
— 80dBm
«Play
back the self recorded tape.
LINE
OUT
connector
(terminated
by
60002)
1kHz =O
(REF)
7kHz =0 +0.5dB
CH-1:
@RV104/AU-85(C-1)
CH-2:
@RV106/AU-85(E-1)
REC
mode — adj.
PB
mode — check
11-22.
REC
FREQUENCY
RESPONSE
ADJUSTMENT
(SP)
machine
conditions
for
adjustment
spec.
adjustment
*AUDIO
IN
connector:
40Hz
to | LINE
OUT
connector
7kHz
15kHz,
— 80dBm
(terminated
by
6000)
CH-1:
@RV103/AU-85(C-1)
CH-2:
@RV105/AU-85(E-1)
*Set
the
KSP
cassette
tape.
10kHz
*Play
back
the
self
recorded
40Hz = —1
Re
dB
CH-1:
@LV102/AU-83(B-5)
tape.
"
CH-2:
@LV203/AU-84(F-2)
90Hz = 0 + 1.5dB
1kHz = O (REF)
15kHz
SkHz = 0 = 0.508
CH-1: @RV11/AU-83(B-6)
7kHz = 0 = 0.5dB
CH-2: @RV11/AU-84(E-1)
10kHz = O + 0.5dB
15kHz = 0 + 0.5dB
REC
mode - adj.
PB
mode — check
11-9

Advertisement

Table of Contents
loading

Table of Contents