CFE -5100 S Instruction Manual

CFE -5100 S Instruction Manual

Residential ess

Advertisement

Quick Links

CFE-5100 S Residential ESS Manual
About CFE-5100 S ESS
CFE-5100 S can be installed in Parallel, more attention should be paid for the DIP
and address selection following with part 5.3.2.
About this Manual
The Manual is intended for theCFE-5100 S Residential ESS, the hybrid inverter and
any other equipment is not included.
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for CFE CFE-5100 S

  • Page 1 CFE-5100 S Residential ESS Manual About CFE-5100 S ESS CFE-5100 S can be installed in Parallel, more attention should be paid for the DIP and address selection following with part 5.3.2. About this Manual The Manual is intended for theCFE-5100 S Residential ESS, the hybrid inverter and any other equipment is not included.
  • Page 2: Table Of Contents

    Contents 1 Safety Instructions ........................3 1.1 Important Safety Instructions ................... 3 1.2 Warnings in this Document ..................... 3 1.3 Battery handing guide ..................... 3 1.4 Response to emergency situations ................. 3 1.4.1 Leaking batteries ....................... 4 1.4.2 Fire ..........................4 1.4.3 Wet battery ........................
  • Page 3 7 Commissioning ........................24 7.1 Commissioning battery ....................24 7.2 Shutting down battery ....................24 8 Troubleshooting ........................24 9 Firmware Update ........................26 9 Warranty of CFE Residential ESS ............错误!未定义书签。 10 RED Declaration of Conformity (DoC) ................31...
  • Page 4: Safety Instructions

    A warning describes a hazard to equipment or personnel. It calls attention to a procedure or practice, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the CFE equipment and/or other equipment connected to the CFE equipment or personal injury.
  • Page 5: Leaking Batteries

    If the battery catches fire, it will produce poisonous gases. Do not approach. 1.4.3 Wet battery If the battery is wet or submerged in water, do not try to access it. Contact CFE customer careline or your distributor for technical assistance. 1.4.4 Damaged battery...
  • Page 6: Installers

    48h 1.5 Installers CFE Energy Storage battery is suggested to be installed by skilled worker or electrician. A skilled worker is defined as a people who had been trained and qualified electrician or had all of the following skills and experience: ...
  • Page 7: Exploded Views Of Battery

    CE & TUV(IEC 62619, IEC 62040) Hanrzd Class of Dangerous Goods Transportation UN38.3  Testing Conditions Based on Temperature 25℃ at The Beginning of Life.  Total Energy/Usable Energy Measured Under Specific Conditions From CFE 0.2C CC/CV 2.2 Exploded views of battery...
  • Page 8: Indicator And Ports

    2.3 Indicator and ports There are two LED indicators on the front of the battery to show its operating status. Table 2-1 Designations on the battery Item Designation Definition Running Battery normally working without fault Fault Battery is in a warning state, see troubleshooting in Chapter 8 2.4 Communication interface plat(DVC-A2 voltage)...
  • Page 9: How It Works

    2.6 Feature The CFE Residential ESS has following features:  Energy storage unit: This battery is suit for PV solar system compatibility.  Battery management system (BMS): The battery built-in BMS monitors It prevents the battery from running outside of the design.limitations.
  • Page 10: Guidance For Disconnection Of Batteries During Shipment

    2) The DC circuit of CFE Residential ESS has been disconnected before outgoing. 3) A precautionary label had been affixed to the shipping carton to alert individuals as to the battery within the package have been disconnected;...
  • Page 11: Installation Process

     Minimal dust and dirt in the area.  No corrosive gases present, including ammonia and acid vapor. The CFE Residential ESS is rated at IP20, so the battery could be installed indoor. If the ambient temperature is outside the operating range, battery will protect itself by shutting down.
  • Page 12: Installation Materials

    NOTICE Make sure that the cross-sectional area of charging cables is 25 to 35 A breaker between CFE battery and inverter was recommended to install, and the breaker’s min. current should be over 150A or following with local regulations.
  • Page 13: Network Cable

    Insulated glove Safety goggles Safety shoes 4.6 Network cable If needed, the network cable should be made like that diagram. But the network cable between battery and Inverter should be made following the definition of Inverter. If available, use a LAN cable tester to check whether the cable is faulty. 4.7 Storage If the battery is not to be installed immediately, or removed from operation and needs to be stored for a long period, please choose an appropriate location to...
  • Page 14: Battery Installation

    Press and hold the panel button for about 4s and then release it after the two LED lights on, measure the voltage at the terminal interface with a voltmeter. If the voltage is lower than 48 V, do not use the battery and contact CFE customer careline or your distributor.
  • Page 15: Installation The Battery

    5.3 Installation the battery NOTICE The symbol located on the front of battery, For Parallel connection, the earth wire was recommended to be installed. 5.3.1 Connect with 51.2Vdc Inverter To prevent the battery from moving, make sure the battery fixed to a wall. NOTICE If the battery is installed above the floor or on a platform, make sure that the wall or platform is capable of supporting the battery’s weight.
  • Page 16: Ground Installation

    Note: if more than 4 batteries installed, a cabinet recommended to be selected for the battery’s stable. 5.3.1.2 Ground installation Meanwhile, CFE-5100 S battery also could be installed on floor, the installation step as following: 1. Fix the braced feet to battery’s mounting holes one by one.
  • Page 17: Address Selection Of Master And Slave Battery(Ies) Connection

    5.3.2 Address selection of Master and Slave battery(ies) connection WARNING Please make sure the SW2 DIP switch selected correctly, if the battery connected in Parallel mode, but select SW2 DIP8 at ON position, probably lead serious fault even dangerous. Connected Set of SW2 Address Set battery...
  • Page 18 Slave 3 Slave 4 Master Slave 1 Slave 2 Slave 3 Slave 4 Slave 5 Master Slave 1 Slave 2 Slave 3 Slave 4 Slave 5 Slave 6 Master Slave 1 Slave 2 Slave 3 Slave 4 Slave 5 Slave 6 Slave 7 Master...
  • Page 19: Cable Connections

    Slave 1 Slave 2 Slave 3 Slave 4 Slave 5 Slave 6 Slave 7 Slave 8 Master Slave 1 Slave 2 Slave 3 Slave 4 Slave 5 Slave 6 Slave 7 Slave 8 Slave 9 5.4 Cable connections WARNING Before connecting battery with inverter, please make sure that no inverter connected or the inverter turned off.
  • Page 20: Cable Connection For Parallel Connection

    5.4.1 Cable connection for Parallel connection 5.4.1.1 Ground installation For parallel installation, please pay attention on Cable connection, and the DIP8 of SW2 no need to be changed and stayed on Initial Factory state. 5.4.1.2 Wall mounting For wall mounting, the battery connection number should be less than 4, if more batteries installed, a cabinet was recommended.
  • Page 21: Configuration

    If parallel connecting multiple batteries, please set the DIP switches as following: 6.1 Configure device WIFI The CFE Residential ESS has a built-in WIFI module for use with the CFE APP. The WIFI setting of battery should be as following...
  • Page 22 Step Press and hold the Reset button for 7 seconds. Connect the ‘USR-WIFI232-XX_XXXX’ with your smart phone, and then the light of WIFI will turn on by itself within 5 seconds. Open the APP monitor of battery, select ‘Config Device Wifi’ option box.
  • Page 23: Register Your Account

    Search and select SSID connected and input the password, press ok and finish. The light of WIFI module would light automatically under WLAN accessible condition. NOTICE If the WIFI cannot be set or there is no WLAN accessible, the battery can still operate normally.
  • Page 24: Settings For Can /485 Bus Pins

    NOTICE The CFE Residential ESS could be registered only one time. The CFE Residential ESS running is not associated with registration or not. 6.3 Settings for CAN /485 bus pins Confirm that the CANL/485B DIP switch is set to SW4 which pin is used for CAN high signal by inverter (4-CANH/485A), and the CANL/485B DIP switch is set to SW5 which pin is used for CAN low signal by inverter (5-CANL/485B).
  • Page 25: Commissioning

    1) Check battery voltage level is above 48V If battery voltage is under 48V contact your distributor or CFE after service customer careline for help. 2) Press and HOLD the panel button for about 4s, after four seconds the indicator lights will turn on.
  • Page 26 2) If the battery fault light on, pls check the Troubleshooting number in Homepage in your CFE APP, if the code is 0x1***, this problem would be recovered by itself. But if the code is 0x2*** or 0x3***, please contact the CFE after service customer careline or your distributor for help.
  • Page 27: Firmware Update

    0x3001 Address select fault 9 Firmware Update It is possible to update the BMS firmware version manually via the WIFI monitor system App. After a new firmware version is uploading to the server, the firmware could be updated over the Internet by itself after holder confirmed.
  • Page 28: Warranty Of Cfe Residential Ess

    E-mail:sales@cfenergygroup.com Warranty of CFE Residential ESS This warranty specified below applies to ESS supplied by CFE, CFE LFP battery to consumer through authorized reseller. The accessories and tool kits provided are not included. If the unit suffers major failure you will be provided with a replacement unit and your warranty will be transferred to the new unit.
  • Page 29 Product damage and defect caused by deliberately or willful act. Products failure is not reported to seller or CFE authorized service partner within 1 week of appearance. The Product not being operated for any period of 6 months or more.
  • Page 30 If the product is no longer sold in the market, CFE would replace it with different kind of product with equal or higher functions and performances, or the residual annual depreciation value of the buyer paid price within the time limit for performance guarantee.
  • Page 31 Out Of Warranty In the event the Product is out of warranty, CFE may (in its discretion) provide certain after-sales service to Original Buyer, but all the costs and expenses, such as parts, labour costs and travel expenses, shall be borne by Original Buyer. To request such...
  • Page 32: Red Declaration Of Conformity (Doc)

    Rechargeable Lithium ion battery System trade name: type or model: CFE-5100S relevant supplementary information: ................(e.g. lot, batch or serial number, sources and numbers of items) to which this declaration relates is in conformity with the essential requirements and other relevant requirements of the RED Directive (2014/53/EU).

Table of Contents