Vantron S108 Series User Manual

Vantron S108 Series User Manual

Unmanaged industrial switches

Advertisement

Quick Links

Vantron
| Embedded in your success, Embedded in your better life
World-leading provider of embedded/IoT products and solutions
S108 Series Unmanaged Industrial Switches
User Manual
Version: 1.2
© Vantron Technology, Inc. All rights reserved.
S108 Series Industrial Switches | User Manual
www.vantrontech.com

Advertisement

Table of Contents
loading

Summary of Contents for Vantron S108 Series

  • Page 1 | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions S108 Series Unmanaged Industrial Switches User Manual Version: 1.2 © Vantron Technology, Inc. All rights reserved. S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 2 World-leading provider of embedded/IoT products and solutions Revision History Description Date V1.0 First release Oct. 21, 2022 V1.1 Updated I/O description Jan. 8, 2023 V1.2 Updated the setup instructions May 17, 2023 S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 3: Table Of Contents

    Definition of LED Indicators .................... 18 2.4.1 Link/activity indicator of RJ45 jacks ................18 CHAPTER 3 DEVICE CONNECTION ..................... 20 Usage of S108 Series Unmanaged Switches ..............21 Typical Connection ......................22 CHAPTER 4 DISPOSAL AND WARRANTY .................... 23 Disposal .......................... 24 Warranty .........................
  • Page 4: Foreword

    Under no circumstances shall any part of this user manual be copied, reproduced, translated, or sold. This manual is not intended to be altered or used for other purposes unless otherwise permitted in writing by Vantron. Vantron reserves the right of all publicly released copies of this manual.
  • Page 5 Symbology This manual uses the following signs to prompt users to pay special attention to relevant information. Caution for latent damage to system or human injury Attention to important information or regulations S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 6 The use or placement of the operation tools shall comply with the code of practice of such tools to avoid short circuit of the Product. Cut off the power before inspection of the Product to avoid human injury or product • damage. S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 7 Clean with a damp cloth • Do not try to clean exposed electronic components unless with a dust collector Power off and contact Vantron technical support engineer in case of the following faults: The Product is damaged • The temperature is excessively high •...
  • Page 8: Chapter 1 Introduction

    Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions CHAPTER 1 INTRODUCTION S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 9: Product Overview

    World-leading provider of embedded/IoT products and solutions 1.1 Product Overview As part of Vantron’s overall solution for industrial automation, Vantron S108 series is a collection of four unmanaged industrial switches that feature 8 Gigabit Ethernet ports to demonstrate excellent data transfer performance.
  • Page 10: Unpacking

    1 x DIN rail 1 x DC power mounting bracket connector (attached) Actual accessories might vary slightly from the list above as the customer order might differ from the standard configuration options. S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 11: Specifications

    Industrial Standard IEC61000-4-4 (EFT): Power port: ±2kV, Data port: ±1kV Standard IEC61000-4-5 (Surge): Power port: ±1kV/DM, ±2kV/CM, Data port: ±1kV/DM, ±2kV/CM IEC61000-4-6 (CS): 10V (150kHz~80MHz) (Mechanical) IEC60068-2-6 (Vibration) IEC60068-2-27 (Shock) IEC60068-2-32 (Free fall) S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 12: Block Diagram

    Transformer QSGMII VSC7512 VSC8514 G4P109NM-A Console UART RS232 SP3222EEY 95040-2881 125Mhz Relay GPIO Crystal OQ0253510000G HFD3/5 Serial 2*SERDES 74HC164PW Temperature: Operate: -20 ~ +70℃ Storage: -40 ~ +85℃ LEDs WP934SA/3GD SFP11-A0-0900 SFP11-A0-0900 S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 13: Product Layout

    World-leading provider of embedded/IoT products and solutions 1.6 Product Layout 1.6.1 Front View 4 x LED indicator (SFP port status) Reset button 3 x LED indicator 8 x RJ45 port 2 x SFP port (Device status) S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 14 | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions 1.6.2 Back View DIN rail bracket 1.6.3 Left side view Enclosure grounding DC in Relay S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 15: Mechanical Dimensions

    • 1.8 Power Supply and Consumption S108 series industrial switches work with 12V-48V DC power input supplied by a DC connector that supports dual redundant power supply, and is reinforced by over-current protection, reverse polarity protection. The power consumption of the device is less than 3W when idled and less than 7.5W with full load.
  • Page 16: Chapter 2 Getting Started

    Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions CHAPTER 2 GETTING STARTED S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 17: Device Setup

    3. Push the switch down to compress the spring of the bracket; 4. Release the switch when there is enough space for the downside of the DIN rail bracket to fit the other side of the DIN rail; S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 18: Starting The Device

    (12V to 48V DC) to turn on the device. 2.2 Starting the Device S108 series unmanaged industrial switches offer a plug-and-play solution, and users need only to connect the switch to a power source to start using the device. There is no requirement for additional configurations.
  • Page 19: I/Os

    The connector supports a load capacity of 1A @24V DC. Pin 1 Pinout description: Signal Description Relay_in Relay input Relay_out Relay output S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 20: Grounding Screw Hole

    100M/1G data rate and SFP2 (G10) that supports 100M/1G/2.5G auto adaptive data rate. Each Ethernet jack has two LED indicators to indicate the link/activity status of the network. Description of the status indicator is detailed in the following section. S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 21: Definition Of Led Indicators

    Definition of the each set of indicators is as follows: LED Indicator Description Off: 10/100M data rate Link Solid green: 1000M data rate Off: link down Activity Solid green: link up Blinking: data transferring S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 22 Definition of the each set of indicators is as follows: LED Indicator Description Off: link down Link Solid green: link up Off: link down Activity Solid amber: link up Blinking: data transferring S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 23: Chapter 3 Device Connection

    Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions CHAPTER 3 DEVICE CONNECTION S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 24: Usage Of S108 Series Unmanaged Switches

    IP-based surveillance cameras. Switches are usually used in harsh environments that require stable operation and involve data interaction between a range of devices. Vantron S108 series is particularly designed for rail transit, smart city, intelligent mining, etc.
  • Page 25: Typical Connection

    3.2 Typical Connection The following is a simple connection topology of S108-FR in the application of traffic surveillance. Router Internet S108-FR switch Traffic lights Dispatch center Weather sensors CCTV Video Radio surveillance station S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 26: Chapter 4 Disposal And Warranty

    Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions CHAPTER 4 DISPOSAL AND WARRANTY S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 27: Disposal

    Proper disposal of this sort of waste helps avoid harm and adverse effect upon surroundings and people’s health. Please contact local organizations or recycling/disposal center for more recycling/disposal methods of related products. S108 Series Industrial Switches | User Manual www.vantrontech.com...
  • Page 28: Warranty

    CUSTOMER’s location and no Product so inspected shall be returned to VANTRON unless the cause for the rejection or defect is determined to be the responsibility of VANTRON. VANTRON shall in turn provide the CUSTOMER turnaround shipment on defective Product within fourteen (14) working days upon its receipt at VANTRON.
  • Page 29: Appendix Regulatory Compliance Statement

    Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate this equipment. S108 Series Industrial Switches | User Manual www.vantrontech.com...

This manual is also suitable for:

S108-bS108-fS108-rS108-fr

Table of Contents