  • Page 1 Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions S105 Unmanaged Industrial Switch User Manual Version: 1.2 © Vantron Technology, Inc. All rights reserved. S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 2 World-leading provider of embedded/IoT products and solutions Revision History Description Date V1.0 First release Nov. 21, 2022 V1.1 Updated the definition of LED indicators Apr. 18, 2023 V1.2 Updated the setup instructions Jun. 12, 2023 S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 3: Table Of Contents

    2.3.5 Ethernet jacks ......................... 17 Definition of LED Indicators .................... 18 CHAPTER 3 DEVICE CONNECTION ......................19 Usage of S105 Unmanaged Industrial Switch ..............20 Typical Connection ......................21 CHAPTER 4 DISPOSAL AND WARRANTY ....................22 Disposal .......................... 23 Warranty ......................... 24 Appendix Regulatory Compliance Statement ................
  • Page 4: Foreword

    World-leading provider of embedded/IoT products and solutions Foreword Thank you for purchasing Vantron S105 Industrial Switch (“the Switch” or “the Product”). This manual intends to provide guidance and assistance necessary on setting up, operating and maintaining the Product. Please read this manual and make sure you understand the structure and functionality of the Product before putting it into use.
  • Page 5 Please refer to Appendix for Regulatory Compliance Statement. Symbology This manual uses the following signs to prompt users to pay special attention to relevant information. Caution for latent damage to system or human injury Attention to important information or regulations S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 6 The use or placement of the operation tools shall comply with the code of practice of such tools to avoid short circuit of the Product. Cut off the power before inspection of the Product to avoid human injury or product • damage. S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 7 Clean with a damp cloth • Do not try to clean exposed electronic components unless with a dust collector Power off and contact Vantron technical support engineer in case of the following faults: The Product is damaged • The temperature is excessively high •...
  • Page 8: Chapter 1 Introduction

    Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions CHAPTER 1 INTRODUCTION S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 9: Product Overview

    DIN rail bracket is attached to the back of the enclosure for flexible installation of the device. Switches are usually used in harsh environments that require stable operation and involve data interaction between a range of devices, and the S105 is particularly designed for rail transit, smart city, intelligent mining, etc.
  • Page 10: Unpacking

    & power cord 1 x DIN rail 1 x DC power mounting bracket connector (attached) Actual accessories might vary slightly from the list above as the customer order might differ from the standard configuration options. S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 11: Specifications

    12V~48V DC (48V-53.2V DC for PSE feature), 1 x 3 x 3.81mm Input terminal block Power (Over-current protection, reverse polarity protection) Consumption < 32.1W (with four S105 connected) Operating: -20℃ ~ +75℃ Temperature Storage: -40℃ ~ +85℃ Environment Humidity Operating: RH 5-95% (Non-condensing)
  • Page 12: Block Diagram

    SG24719PT_A LAN1 AC125@0.5A C8T6 10/100Base-Tx RJ45 Transformer SG24719PT_B DIP Switch GPIOs 3.3V SGM2028 IP804 53.5V DC-DC SGM61720 Temperature: 2.5A Operate: -20 ~ +75°C, 53.5V Storage: -40 ~ +85°C DC IN 1x3x3.81mm Adapter 53.5V@40W S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 13: Product Layout

    World-leading provider of embedded/IoT products and solutions 1.6 Product Layout 1.6.1 Front View 4 x PoE Power + Link 5 x RJ45 (PSE supported by indicator indicators ETH 1-4/PD by ETH 5) 1.6.2 Back View DIN rail bracket S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 14 Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions 1.6.3 Left side view DIP switch Power Relay terminal 1.6.4 Right side view Grounding screw S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 15: Mechanical Dimensions

    The switch is designed to connect a 48V-53.2V DC when working in PSE mode. Its power consumption is less than 32.1W when four S105 switches are connected.
  • Page 16: Chapter 2 Getting Started

    Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions CHAPTER 2 GETTING STARTED S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 17: Device Setup

    3. Push the switch down to compress the spring of the bracket; 4. Release the switch when there is enough space for the downside of the DIN rail bracket to fit the other side of the DIN rail; S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 18: Starting The Device

    48V-53.2V DC. 2.2 Starting the Device The S105 unmanaged industrial switch offers a plug-and-play solution, and users need only to connect the switch to a power source to start using the device. There is no requirement for additional configurations.
  • Page 19: I/Os

    Enclosure grounding 2.3.2 Relay The S105 offers a relay connector that can be used to connect an alarm to notify the user when the device connected to a specific Ethernet jack is disconnected. The relay is designed to be used in combination with the DIP switch to monitor the connectivity of a specific Ethernet jack.
  • Page 20: Dip Switch

    PD feature. These Ethernet jacks can be controlled by DIP switches 2-6, respectively and DIP switch 1 controls all the jacks. Ethernet jacks 1-4 Ethernet jack 5 (Optional feature: PSE) (Optional feature: PD) S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 21: Definition Of Led Indicators

    (Slow blinking: a device is connected to the corresponding Ethernet jack; fast blinking: data transfer is ongoing) Variants not supporting PSE feature (such as standard S105 or S105-PD (with PD feature)) are not provided with PoE indicators. S105 Industrial Switch | User Manual...
  • Page 22: Chapter 3 Device Connection

    Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions CHAPTER 3 DEVICE CONNECTION S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 23: Usage Of S105 Unmanaged Industrial Switch

    The S105 is suitable for any business network that wants to simplify the installation of wireless access points and IP-based surveillance cameras. Switches are usually used in harsh environments that require stable operation and involve data interaction between a range of devices.
  • Page 24: Typical Connection

    Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions 3.2 Typical Connection The following is a simple connection topology of S105-FR in the application of traffic surveillance. Router Internet S105 switch...
  • Page 25: Chapter 4 Disposal And Warranty

    Vantron | Embedded in your success, Embedded in your better life World-leading provider of embedded/IoT products and solutions CHAPTER 4 DISPOSAL AND WARRANTY S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 26: Disposal

    & electronic waste recycling/disposal center. Proper disposal of this sort of waste helps avoid harm and adverse effect upon surroundings and people’s health. Please contact local organizations or recycling/disposal center for more recycling/disposal methods of related products. S105 Industrial Switch | User Manual www.vantrontech.com...
  • Page 27: Warranty

    CUSTOMER’s location and no Product so inspected shall be returned to VANTRON unless the cause for the rejection or defect is determined to be the responsibility of VANTRON. VANTRON shall in turn provide the CUSTOMER turnaround shipment on defective Product within fourteen (14) working days upon its receipt at VANTRON.
  • Page 28: Appendix Regulatory Compliance Statement

    Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate this equipment. S105 Industrial Switch | User Manual www.vantrontech.com...