Precipitation Sensor Instruction for Use with analogue Intensity Output 5.4103.20.041, 5.4103.20.641, 5.4103.20.741, 5.4103.26.041 Dok. No. 021335/10/23 T H E W O R L D O F W E A T H E R D A T A...
Page 2
Safety Instructions • Before operating with or at the device/product, read through the operating instructions. This manual contains instructions which should be followed on mounting, start-up, and operation. A non-observance might cause: - failure of important functions - endangerment of persons by electrical or mechanical effect - damage to objects •...
4 Installation Please Note: The hydrophilic coating must not be damaged. The electrical connection is to be carried out by experts only. Please open the instrument only with dry ambient conditions. Do not damage the exposed electronics! Remark: In order to achieve an optimal electro-magnetic immunity (> 20V/m) please use shielded cable.
4.2 Electrical Mounting for Precipitation Sensor with Cable Gland For: 5.4103.2x.041, 5.4103.20.641 see circuit diagram in chapter 4. Process: Remove 5 screws at the bottom side of the precipitation monitor. Remove upper part (cover). The connecting terminals are the freely accessible. Insert a respective prepared cable from the bottom through the cable glands situated in the housing bottom, and connect it to the connecting terminals and shield connector, acc.
4.3 Electrical Mounting for Precipitation Sensor with Plug Connection For: 5.4103.20.741, see circuit diagram in chapter 5. 4.3.1 Plug Mounting Applies only to instruments with connection „plug“. Coupling socket, Typ:Binder, Serial 423, EMC with cable clamp Cable connection: without cable shield 1.
4.4 Connecting Diagram Order-No. Clamp connection 5.4103.20.041 5.4103.20.641 5.4103.26.041 Note: The 5.4103.20.641 has a bridge rectifier at the input of the power supply This means, that the power supply "-" does not have the same potential as output "-". Power supply "-" and output "-" must not be connected.
Order-No. Plug connection View on the soldering 5.4103.20.741 side of the counter plug. Remark: The cable shield must only be connected on the side of the power supply. 5 Taking into Operation After the electrical connection has been established, and the case has been screwed, the operating voltage can be switched on.
We recommend the threads of the plugs with a suitable corrosion inhibitors to protect against corrosion. 7 Technical Data Measuring Value Precipitation intensity (mm / min) Output Constant current, depending on measuring value, between 4.0mA and 20.0mA Measuring range, Output, Measuring range Output Function...
9 Accessories (Optional) Power Supply Unit 9.3388.00.002 The power supply unit provides for the current supply of the Precipitation Sensor. It supplies the necessary operation voltage for the electronics and the heating. Primary : 230V / 50Hz Secondary : 24V AC / 25VA Housing : synthetic Protection...
Product: Precipitation Transmitter Doc. Nr. 902-45218_CE Article Overview : 5.4103.10.000 5.4103.10.012 5.4103.10.112 5.4103.10.700 5.4103.11.000 5.4103.20.041 5.4103.20.741 5.4103.21.021 5.4103.26.041 5.4103.30.000 5.4103.30.700 5.4103.31.000 5.4103.32.000 The indicated products correspond to the essential requirem ent of the follow ing European Directives and Regulations: 2014/30/EU 26.02.2014...
Product: Precipitation Transmitter Doc. Nr. 902-45218_CA Article Overview : 5.4103.10.000 5.4103.10.012 5.4103.10.112 5.4103.10.700 5.4103.11.000 5.4103.20.041 5.4103.20.741 5.4103.21.021 5.4103.26.041 5.4103.30.000 5.4103.30.700 5.4103.31.000 5.4103.32.000 The indicated products correspond to the essential requirem ent of the follow ing Directives and Regulations: 1091 08.12.2016...