MED Associates SG-7000 Series Manual

Tabletop interface cabinets

Advertisement

Quick Links

instrumentation and software for research
SG-7000 SERIES TABLETOP INTERFACE
CABINETS
SG-7108 SMALL TABLETOP INTERFACE CABINET
SG-7308 SMALL TABLETOP INTERFACE CABINET W / POWER SUPPLY
SG-7316 LARGE TABLETOP INTERFACE CABINET W/ POWER SUPPLY
DIG-705 USB INTERFACE DECODER CARD
DOC-327
Rev. 1.0
Copyright ©2022
All Rights Reserved
Med Associates, Inc.
P.O. Box 319
St. Albans, Vermont 05478
Phone: 802.527.2343
Fax: 802.527.5095
www.med-associates.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG-7000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MED Associates SG-7000 Series

  • Page 1 SG-7000 SERIES TABLETOP INTERFACE CABINETS SG-7108 SMALL TABLETOP INTERFACE CABINET SG-7308 SMALL TABLETOP INTERFACE CABINET W / POWER SUPPLY SG-7316 LARGE TABLETOP INTERFACE CABINET W/ POWER SUPPLY DIG-705 USB INTERFACE DECODER CARD DOC-327 Rev. 1.0 Copyright ©2022...
  • Page 2 This page intentionally left blank...
  • Page 3: Table Of Contents

    Card Compatibility ......................... 7 Removing cards from the Tabletop Interface Cabinet ............. 7 Inserting cards into the Tabletop Interface Cabinet ..............8 Appendix A | Contact Information ................9 - iii - DOC-327 Rev. 1.0 Copyright © 2022 Med Associates, Inc.
  • Page 4 M E D A S S O C I A T E S , I NC . S G - 7 X X X Notes _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ Diagrams - iv - DOC-327 Rev. 1.0 Copyright © 2022 Med Associates, Inc.
  • Page 5: Chapter 1 | Introduction

    DIG-704 PCIe Interface Card and the DIG-700G Decoder Card. All SG-7000 Series Tabletop Interface Cabinets contain regulated power supplies with outputs of +/- 15 Volt DC and + 5 Volt DC. The SG-7308 and SG-7316 also contains a 28 Volt power supply with power connectors on the back side of the cabinet to power lights, retractable levers, pellet feeders and other devices.
  • Page 6 S G - 7 0 0 0 SE R I E S T AB L E T O P I N T E R FA C E C A B I NE T S Figure 1.1 - SG-7308 cabinet with DIG-705, DIG-716 cards, and SG-716 connection panels Figure 1.2 - SG-7308 cabinet with DIG-705, DIG-718 cards, and SG-718 connection panels - 2 - DOC-327 Rev. 1.0 Copyright © 2022 Med Associates, Inc.
  • Page 7: Chapter 2 | Power Connections

    Tabletop Interface Cabinet. The total current consumption of all the Connection Panels combined cannot exceed 2.5 A. In practice that limits the number of connection panels to 2 fully loaded SG-718-24 boxes or up to 4 lightly loaded SG-718-12’s. - 3 - DOC-327 Rev. 1.0 Copyright © 2022 Med Associates, Inc.
  • Page 8: Loopback Power Cable (Sg-73Xx To Dig-705 Or Dig-700G)

    Therefore, a ground wire needs to connect the cabinet and the additional 28V power supply. The DIG-718 / SG-718 does not require this additional ground wire. - 4 - DOC-327 Rev. 1.0 Copyright © 2022 Med Associates, Inc.
  • Page 9: Chapter 3 | Dig-705 Usb Interface Decoder Card

    This light indicates that there is a USB cable to the PC, and the PC provides power via this connection. Some computers leave the power on the USB connector even though they are turned off, other computers will only provide power when turned on. - 5 - DOC-327 Rev. 1.0 Copyright © 2022 Med Associates, Inc.
  • Page 10 In addition to the 4 indicator lights on the DIG-705, the DIG-705’s test screen available in the Med-Test Software also provides accurate readings of all voltages, temperature, cabinet info, as well as testing. Figure 3.2: Med-Test, showing cabinet voltages in the Cabinet Info section. - 6 - DOC-327 Rev. 1.0 Copyright © 2022 Med Associates, Inc.
  • Page 11: Chapter 4 | Hardware Installation

    NOTE: Six sided “Torx” screws are used on some cards to attach the face panel to the card. These should never be removed by the customer. - 7 - DOC-327 Rev. 1.0 Copyright © 2022 Med Associates, Inc.
  • Page 12: Inserting Cards Into The Tabletop Interface Cabinet

    When using other cards, the cards need to be configured via DIP-switches or jumpers to have the correct address. The correct way to address these cards can be found in their respective user’s manual or in the Med Test manual (DOC-200) for all cards. - 8 - DOC-327 Rev. 1.0 Copyright © 2022 Med Associates, Inc.
  • Page 13: Appendix A | Contact Information

    Figure 4.3 - (LEFT) card with a keyed backplane connector. ( RIGHT) card without a keyed backplane connector requiring removal of the backplane key if present. APPENDIX A | CONTACT INFORMATION Please contact Med Associates, Inc. for information regarding any of our products. For Technical questions, email support@med-associates.com. For Sales questions, email sales@med-associates.com.